N267AU, cancelled Aug 24, 2004
Service difficulty reports · 56
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N267AU' AND deregistration_id = 'N267AU-2004-08-24' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N267AU' AND deregistration_id = 'N267AU-2004-08-24' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR USAA010452Doubler · crackedCLT - FOUND SKIN DOUBLER CRACKED .09375, BS 178, 12 OCLOCK POSITION, STRINGER 1L. ROUTED OUT DAMAGE (TIME LIMITED REPAIR) PER EA 69533. (M)SDR USAA010451Frame · crackedCLT - FOUND SIDE CHORD CRACKED .5 INCH, BS 178 WL 207 LEFT SIDE. REMOVED DAMAGED SECTION, SPLICED IN NEW CHORD SECTION PER EO 5300V157. (M)SDR USAA010450Frame · crackedCLT - FOUND SIDE CHORD CRACKED, BS 178 WL 207 RIGHT SIDE CHORD. DAMAGED SECTION CUTOUT, SPLICED IN NEW CHORD SECTION PER EO 5300V157. (M)SDR USAASB00355Battery Pack · dischargedBWI - DURING THE OVERNIGHT CHECK, MAINTENANCE FOUND THE FORWARD EMERGENCY EXIT SIGN, AT SEAT ROW 2, INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY PACK. OPS CHECK GOOD. (M)SDR USAASB00285Windshield · crackedBDL - FLT 2612 - EN ROUTE FROM MHT TO BWI, THE FIRST OFFICERS WINDSHIELD CRACKED IN FLIGHT. COCKPIT VISION WAS AFFECTED. CREW DECLARED AN EMERGENCY AND DIVERTED TO BDL. FLIGHT LANDED WITHOUT FURTHER INCIDENT. MAINTENANCE REMOVED AND REPLACED THE FIRST OFFISDR USAASB00171Duct · rupturedTPA - FLT 2704 - ON CLIMB-OUT FROM TPA, AT 6,000 FEET, THE NR 2 ENGINE OVERHEAT LIGHT ILLUMINATED. CREW ACCOMPLISHED QUICK REFERENCE HANDBOOK PROCEDURES. WHEN THROTTLE WAS REDUCED, LIGHT EXTINGUISHED. WHEN THROTTLE WAS ADVANCED, LIGHT ILLUMINATED AGAIN. FLISDR USAASB99246Csd · failedMCO - FLT 2646 - FLIGHT DEPARTED MIA WITH THE NR 1 GENERATOR ON MEL. DURING CRUISE, THE NR 2 GENERATOR LOW OIL PRESSURE LIGHT ILLUMINATED. CREW DISCONNECTED THE NR 2 CSD AND DIVERTED TO MCO WHERE THE FLIGHT LANDED WITHOUT FURTHER INCIDENT. NO EMERGENCY WAS SDR USAASB99235Valve · failedORD - FLT 2704 - AFTER TAKEOFF FROM BWI, THE INBOARD ANTI-SKID LIGHT ILLUMINATED AND DID NOT EXTINGUISH AFTER GEAR RETRACTION. FLIGHT DIVERTED TO ORD FOR MAINTENANCE AND LONGER RUNWAYS. LIGHT REMAINED ON WHEN LANDING GEAR WAS DOWN AS WELL. FLIGHT LANDED WITSDR USAASB99226Power Supply · inoperativeBOS - MAINTENANCE FOUND THE AFT EMERGENCY LIGHT INTERMITTENT. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY. OPERATIONAL CHECK GOOD. (M)SDR USAASB99161Light · inoperableBWI - MAINTENANCE FOUND THE FORWARD EMERGENCY LIGHT ASSEMBLY INOPERABLE AND THE FORWARD ESCAPE SLIDE EMERGENCY LIGHTS AT THE FORWARD ENTRY AND FORWARD SERVICE DOORS INOPERABLE. MAINTENANCE REMOVED AND REPLACED THE FORWARD EMERGENCY LIGHT ASSEMBLY AND THE BATTSDR 99ZZZX2823Battery Pack · dischargedBWI - MAINTENANCE FOUND THE FORWARD EMERGENCY LIGHT ASSEMBLY INOPERABLE AND THE FORWARD ESCAPE SLIDE EMERGENCY LIGHTS AT THE FORWARD ENTRY AND FORWARD SERVICE DOORS INOPERABLE. MAINTENANCE REMOVED AND REPLACED THE FORWARD EMERGENCY LIGHT ASSEMBLY AND THE BATTSDR USAASB99114Connector · looseBWI - FLT 2681 - DURING CLIMB-OUT FROM BWI, THE NR 2 ENGINE FUEL HEAT LIGHT ILLUMINATED. THE NR 2 ENGIN OIL TEMP BEGAN TO EXCEED LIMITS. CREW TRIED DIFFERENT POWER LEVELS, BUT THE OIL TEMPERATURE REMAINED IN THE YELLOW TO RED BAND. CREW DECIDED TO RETURN TOSDR USAA990423Stringer · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT TERMINAL END STRINGER 26R AT STATION 540. INSTALLED NEW END FITTING PER SRM 51-10-01. (M)SDR USAA990391Web · crackedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND A 2 INCH CRACK AT STATION 259 BL 0 CEILING ON NWW VERT STIFFENER WEB. REPAIRED PER SRM 51-10-01 PAGE 5. (M)SDR USAA990390Floorbeam · corrodedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION FOUND A 1 INCH AREA OF CORROSION AT STATION 312 LBL 12 FLOORBEAM. INSTALLED NEW 'T' CAP WITH SPLICES AND REPAIR STRAPS PER TR 53-10-13. (M)SDR USAA990382Floorbeam · corrodedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION FOUND A 1 INCH AREA OF CORROSION AT STATION 312 LBL 1 FLOORBEAM. INSTALLED NEW 'T' CAP WITH SPLICES AND REPAIR STRAPS PER TR 53-10-13. (M)SDR USAA990364Frame · crackedCLT - DURING A Q-C CHECK, VISUAL INSPECTION, FOUND A .125 INCH CRACK AT BS 727 LEFT STRINGER 18A OUTER CHORD FRAME. INSTALLED NEW CHORD PER EO 5394G068 AND EO 5394G076. (M)SDR USAA990363Angle · crackedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND SEVERAL 1 INCH CRACKS AT BS 727 BETWEEN STRINGER 24R AND 25R CHORD ANGLE. REPAIRED PER EA 64377, 64403 AND EO 5394G068. (M)SDR USAA990353Stringer · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 4 INCH BY 2.5 INCH CORRODED AREA AT STRINGER 20L AND STATION 911 AFT CARGO. INSTALLED J ANGLE, U CHANNEL, SHIMS AND CLIP PER SRM 53-10-3 AND SRM 51-20-1. (M)SDR USAA990314Skin · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH CRACK IN FORWARD SERVICE DOOR LOWER AFT CORNER SKIN. INSTALLED EXTERNAL DOUBLER PER T/R 53-10-19 REV A AND EA 64244 AND 64167. (M)SDR USAA990313Skin · crackedCLT - DURING Q-2 CHECK HFEC INSPECTION, FOUND A .09375 INCH CRACK IN FORWARD ENTRY DOOR LOWER HINGE CUTOUT FUSELAGE SKIN. INSTALLED REPAIR DOUBLER AND FILLER PER SRM 53-30-3 FIG 31. (M)SDR USAA990312Angle · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH CRACK IN FLOORBEAM TO FUSELAGE ATTACH ANGLE AT BS 597, RBL 70.85 AND WL 204-208. INSTALLED ANGLE REPAIR PER EA 64287. (M)SDR USAA990309Creasebeam · corrodedCLT - DURING VISUAL CHECK INSPECTION, FOUND SEVERAL AREAS OF CORROSION AT BS 270 TO BS 360 STRINGER 17L CREASEBEAM INNER CHORD ANGLE. REPAIRED PER BOEING DRAWING 65-17688 AND SRM 51-30-3. (M)SDR USAA990303Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 2 INCH AREA OF CORROSION AT BS 947 RBL 6 FLOORBEAM. INSTALLED REPAIR ANGLES AND FILLERS PER SRM 53-10-09 PAGE 26 THROUGH PAGE 30. (M)SDR USAA990302Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM STATION 986.5. SPLICED IN NEW SECTION OF FLOORBEAM 'T' CAP PER TR 53-60-01 AND EA 64288. (M)SDR USAA990301Floorbeam · corrodedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND CORROSION ALONG TOP SURFACE OF FLOORBEAM AT STATION 967, CORROSION TASK NR C53-107-02. SPLICED IN NEW 'T' CAP AND DOUBLER PER SRM 53-10-9 FIG 2 AND EA 64204. (M)SDR USAA990300Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM STATION 328 LBL 12 AND RBL 1. INSTALLED NEW 'T' CAP REPAIR ANGLES AND STRAPS PER TR 53-10-13. (M)SDR USAA990299Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOORBEAM STATION 294.5 BL 0. SPLICED IN NEW 'T' CAP PER TR 53-10-04B. (M)SDR USAA990298Cap · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A 4 INCH AREA OF CORROSION AT BS 344 LBL 6 AND LBL 10 FLOOR 'T' CAP, CORROSION TASK NR C53-107-01. INSTALLED NEW 'T' CAP REPAIR ANGLES AND CAPS PER TR 53-10-13. (M)SDR USAA990297Floorbeam · corrodedCLT - DURING A Q-2 CHECK, VISUAL INSPECTION, FOUND SEVERAL 1 INCH AREAS OF CORROSION AT STATION 967 BETWEEN LBL 10 AND RBL 50 FLOORBEAM. SPLICED IN NEW 'T' CAP PER SRM 53-10-09 AND EA 64202. (M)SDR USAA990296Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON SURFACE TOP OF FLOORBEAM STATION 1006, CORROSION TASK NR C53-107-02. SPLICED IN NEW 'T' CAP PER SRM 53-10-09 AND EA 64206, R 53-10-13. (M)SDR USAA990291Floorbeam · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY .5 INCH AREA OF CORROSION AT STATION 947 RBL 6 ON FLOORBEAM, CORROSION TASK NR C53-107-02. INSTALLED ANGLE PER SRM 53-10-9. (M)SDR USAA990290Angle · corrodedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .5 INCH BY 20 INCH AREA OF CORROSION AT STATION 947 TO STATION 1016 LBL 53 INNER CHORD ANGLE, CORROSION TASK NR C53-107-02. REPAIRED PER SRM 51-10-1. (M)SDR USAA990289Floorbeam · corrodedCLT - DURIGN Q-2 CHECK VISUAL INSPECTION, FOUND A 1 INCH AREA OF CORROSION ON FLOORBEAM AT STATION 328 LBL 12 AND RBL 1, CORROSION TASK NR C53-107-02. SPLICED IN NEW 'T' CAP PER TR 53-10-13. (M)SDR USAA990259Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 767 STRINGER 16R TIE CLIP. REPAIRED PER SRM 51-10-01. (M)SDR USAA990220Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 847 STRINGER 1 TIE CLIP. INSTALLED NEW TIE CLIP PER EO NR 5393G227. (M)SDR USAA990214Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 767 STRINGER 10R TIE CLIP. REPLACED PART. (M)SDR USAA990213Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRCK BS 787 STRINGER 10L TIE CLIP. REPLACED PART. (M)SDR USAA990212Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 727 STRINGER 8L TIE CLIP. REPLACED PART. (M)SDR USAA990211Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND .25 INCH CRACK BS 727A STRINGER 1 TIE CLIP. REPLACED PART. (M)SDR USAA990210Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 727B STRINGER 8R TIE CIP. REPLACED PART. (M)SDR USAA990209Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 727B STRINGER 15R TIE CLIP. REMOVED ORIGINAL CLIP AND HFEC PART AND STRINGER, NO CRACK FOUND. REINSTALLED ORIGINAL PART PER SRM 51-30-02. (M)SDR USAA990208Tie Clip · crackedCLT - DURING Q-2 CHECK VISUAL INSPECTION, FOUND A .25 INCH CRACK BS 727B STRINGER 5R TIE CLIP. REPLACED PART. (M)SDR USAASB99047Power Supply · inoperativeCLT - PILOT REPORTED VARIOUS CABIN AND FLOOR PATH EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD AND AFT CABIN POWER SUPPLIES AND BATTERY PACKS. OPERATIONAL CHECK GOOD. ALSO, REPLACED FORWARD ENTRY AND SERVICE DOOR EMERGENCY EXSDR 99ZZZM195Battery · dischargedCLT - PILOT REPORTED VARIOUS CABIN AND FLOOR PATH EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD AND AFT CABIN POWER SUPPLIES AND BATTERY PACKS. OPERATIONAL CHECK GOOD. ALSO, REPLACED FORWARD ENTRY AND SERVICE DOOR EMERGENCY EXSDR 99ZZZM194Battery Pack · dischargedCLT - PILOT REPORTED VARIOUS CABIN AND FLOOR PATH EMERGENCY LIGHTING INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE FORWARD AND AFT CABIN POWER SUPPLIES AND BATTERY PACKS. OPERATIONAL CHECK GOOD. ALSO, REPLACED FORWARD ENTRY AND SERVICE DOOR EMERGENCY EXSDR USAA970090Skin · crackedGSO - DURING TRANSIT CHECK VISUAL, VERIFIED BY EDDY CURRENT INSPECTION, FOUND TWO .25 INCH CRACKS LEFT FORWARD SERVICE DOOR, SKIN AT AFT CORNERS OF LOWER HINGE CUT OUT. INSTALLED DOUBLER, REPAIRED PER TYPICAL REPAIR 52-40-03A. (M)SDR USAA970089Skin · crackedGSO - DURING TRANSIT CHECK VISUAL, VERIFIED WITH EDDY CURRENT INSPECTION, FOUND 1.5 INCH CRACK IN SKIN FUSELAGE RIGHT SIDE, STATION 764, STRINGER 19R. INSTALLED DOUBLER, REPAIRED PER TYPICAL REPAIR 53-30-3 FIG 6. (M)SDR USAA960784Stringer · corrosionROA - DURING CX-4 CHECK, VISUAL INSPECTION FOUND 2 INCH BY 12 INCH CORROSION, STR 27L, BS 967. REMOVED CORROSION AND INSTALLED DOUBLER AND SPLICED, REPAIRED PER SRM 53-10-3, FIG 1. (X)SDR USAASB96197Fuel Heat Vlv · stuck openCMH - FL 1183 - DURING CLIMB AT FL 280, CAPTAIN SHUT DOWN THE NR 1 ENGINE DUE TO HIGH OIL TEMPERATURE. THE OIL TEMPERATURE WAS IN THE YELLOW BAND FOR APPROX 15 MINS PRIOR TO SHUTDOWN. CREW DECLARED AN EMERGENCY AND DIVERTED TO CMH WHERE THE FLIGHT LANDED WIT