N822BX, cancelled May 1, 2014
Service difficulty reports · 222
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N822BX' AND deregistration_id = 'N822BX-2014-05-01' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N822BX' AND deregistration_id = 'N822BX-2014-05-01' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR IXXA110044OStriker · bentDURING CRUISE, THE MLG DOOR LIGHT REMAINED ON. THE CREW CYCLED THE MAIN LANDING GEAR AND LIGHT REMAINED ON. WHEN AIRSPEED INCREASED TO 210 IAS LIGHT WENT OUT. THEY LANDED WITHOUT FURTHER INCIDENT. MX TROUBLESHOT AND FOUND THE RT GEAR DOOR STRIKER BENT. THSDR IXXA110023OWire Harness · defectiveDURING CLIMBOUT FROM KTOL NR ONE EGT ANALOG AND DIGITAL READ OUTS DROPPED FROM 700 DEGREE TO 420 DEGREE WITH FLUCTUATION PLUS/ MINUS 5 DEGREE, N1 AND N2 SIMILAR TO THE OTHER 3 ENG. ALL 4 THROTTLES WERE ALIGNED. THE CREW RETURNED TO DEPARTURE WITHOUT FURTHER SDR IXXA100053SSkin · corrodedDURING ROUTINE B-CHECK, INSP FOUND CORROSION ON FUSELAGE SKIN AT STA 73 LONGERON 31 RT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED CORRODED SKIN. FABRICATED NEW SKIN. CLEANED, TREATED, PRIMED AREA AND REPAIR PARTS. INSTALLED NEW FASTENERS AND REPSDR IXXA100021OValve · leakingDURING CRUISE, THE RT HYD PRESSURE WAS AT ZERO AND THE LT HYD WAS FLUCTUATING. THE CREW RETURNED TO DEPARTURE WITHOUT FURTHER INCIDENT. MX FOUND RESERVOIR DEPRESSURIZTION VALVE LEAKING. REPLACED RESERVOIR DEPRESSURIZATION VALVE. OPS CHECK GOOD IAW UAL MM29-13-SDR IXXA100016OPump · crackedDURING CRUISE, THE AILERON AND RUDDER REVERSION LIGHT CAME ON, THE CREW ALSO NOTICED LOSS OF HYD PRESSURE AND QUANTITY. CREW ACCOMPLISHED PROCEDURES IAW QRH NR 27. DECLARED EMERGENCY LANDING WITHOUT FURTHER INCIDENT. MX FOUND CABIN AIR CHECK VALVE CLOGGED ANSDR IXXA100006SSkin · crackedLT WING LOWER SKIN CRACKED AT STATION 428.0. REPAIRED SKIN IAW CASTLE SKETCH 20100104028.SDR IXXA100004SStringer · crackedLT WING STRINGER 62 CRACKED. REPAIRED STRINGER IAW SRM 57-2-1 AND CASTLE SKETCH 20100104018.SDR IXXA100005SStringer · crackedLT WING STRINGER 63 CRACKED. REPAIRED STRINGER 63 IAW SRM 57-2-1 AND CASTLE SKETCH 20100104018.SDR IXXA100003SStringer · crackedRT WING FOUND STRINGER 62 CRACKED. REPAIRED STRINGER 62 IAW SRM 57-2-2.SDR IXXA100002SSkin · crackedRT WING LOWER SKIN CRACKED BETWEEN FWD AND AFT OF STRINGER 62. REPAIRED SKIN IAW SRM 57-2-1.SDR IXXA090074OAdi · defectiveDURING CLIMB OUT, CAPTAIN’S FLIGHT DIRECTOR INDICATOR READ’S DIFFERENT FROM THE F/O FLIGHT DIRECTOR INDICATOR, ALSO READ’S DIFFERENT IN FLIGHT LEVEL AND DESCENT. THE CREW RETURNED TO DEPARTURE WITHOUT FURTHER INCIDENT. MX REPLACED CAPTAIN’S FLIGHT DIRECTOR INSDR IXXA090070ORelief Valve · defectiveDURING CLIMB OUT, HYD PRESSURE DROPPED TO ZERO, AILERON AND MANUAL REVERSION LIGHTS ILLUMINATED. THE CREW ACCOMPLISHED ALL PROCEDURES IAW QRH, NO LOSS OF HYD QUANTITY. THE CREW RETURNED TO DEPARTURE WITHOUT FURTHER INCIDENT. MX INSPECTED AND REPLACED DUAL FILTSDR IXXA090054ORmi · defectiveDURING CRUISE, THE COMPASS CARD ON NR 2 RADIO MAGNETIC INDICATOR FROZE IN POSITION. AFTER SEVERAL MINUTES THE COMPASS CARD STARTED MOVING BUT IS 180 DEGREE OFF OF AIRCRAFT HEADING. THE CREW RETURNED TO KLRD WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED NR 2 RSDR IXXA090046OFire Loop · defectiveDURING CLIMB OUT, NR 4 FIRE WARNING HORN SOUNDED, THEN SILENCED AND SOUNDED AGAIN. THE CREW DISCHARGED BOTH BOTTLES AND SHUTDOWN NR 4 ENGINE. CREW RETURNED TO DEPARTURE WITHOUT FURTHER INCIDENT. MX REPLACED CORE FIRE LOOP, CORE LOOP CONNECTORS AND BOTH FIRESDR IXXA090045ORadio · defectiveDURING CLIMB OUT, NR 2 VHF RADIO WILL NOT TRANSMIT FROM ANY POSITION. THE CREW RETURNED TO DEPARTURE AND LANDED WITHOUT INCIDENT. MX REPLACED FIRST OBSERVERS AUDIO SELECT PANEL AND VHF/FM COMM TRANSCEIVER. OPS CHECK GOOD IAW MM 23-20-1, AND 23-50-1. ACFT WASSDR IXXA090014OWire · defectiveDURING CRUISE FROM KPHL, BOTH AILERON AND RUDDER MANUAL LIGHTS CAME ON, HYDRAULIC SYSTEM PRESSURE INDICATED ZERO, HYDRAULIC QUANTITY SHOWS FULL. THE CREW ACCOMPLISHED LOSS OF HYDRAULICS CHECKLIST IN DC-8 QRH. THE CREW LANDED IN KTOL WITHOUT FURTHER INCIDENT.SDR IXXA090009OFire Loop · false activationDURING CLIMB FROM MGUM NR 4 ENGINE SHORT CIRCUIT LIGHT ILLUMINATED, FIRE WARNING WOULD NOT TEST. THE CREW SHUTDOWN NUMBER FOUR ENGINE PER COM PROCEDURES. WIND MILLING OIL PRESSURE WAS 3PSI. THE CREW LANDED IN KNGU WITHOUT FURTHER INCIDENT. MAINTENANCE REPLSDR G412008F00000Ground Wire · brokenAFTER TAKEOFF FROM KIAH, NR 1 ENGINE FIRE WARNING SOUNDED, FIRE HANDLE LIGHT, AND MASTER FIRE WARNING LIGHT ILLUMINATED. WARNING HORN COULD BE SILENCED BUT CAME BACK ON THREE TIMES. ENGINE FIRE HANDLE SUBSEQUENTLY PLACED IN SELECT AGENT POSITION; LIGHT AND HSDR IXXA08SMN090SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT NUMBER 5 TRACK NUT BARRIER FITTING CRACKED AT STATION 70.000. REMOVED CRACKED FITTING. FABRICATED NEW FITTING. PERFORMED MAGNETIC PARTICLE INSPECTION. NO CRACK, NO CORROSION FOUND. CLEANED, TRSDR IXXA08SMN081SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT FITTING CRACKED AT STATION 857.000 LONGERON 1. REMOVED CRACKED FITTING. FABRICATED FITTING PERFORMED LIQUID PENETRANT INSPECTION. NO CRACK, NO CORROSION FOUND. CLEANED, TREATED AND PRIMED AREASDR IXXA08SMN088SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT INBOARD FLAP LOWER FORWARD PANEL PLATING DENTED AT STATION XW 2.000 - STA XW 91.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN, AND BONDED DOUBLER. BONDED PARTS AS SDR IXXA08SMN087SSkin · crackedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING CENTER LEADING EDGE LOWER INNER SKIN INBOARD SPLICE CRACKED AT STATION XFS 341.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. SDR IXXA08SMN085SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT ELEVATOR LOWER SKIN DENTED AT STATION XE 246.875. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN, FINGER DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANED, TREATED ANSDR IXXA08SMN084SSkin · misrepairedDURING ROUTINE C CHECK, FOUND AT EXTERNAL DOUBLER AFT LOWER FUSELAGE BELLY TAIL SKID FAIRING HAS IMPROPER REPAIR AT STATION FS 1745 LONGERON 35.5 LEFT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED SKIN. FABRICATEDSDR IXXA08SMN082SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO FRAME FITTING CRACKED AT STATION 879.000 LONGERON 18 RIGHT TO LONGERON-19 RIGHT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED CRACKED FITTING. PERFORMED NDT INSPECTION. NO CRACK NO CORROSION FOUSDR IXXA08SMN089SSkin · misrepairedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING LEADING CENTER LEADING EDGE OUTER SKIN LOWER SHOWS IMPROPER REPAIR AT STATION XFS 385.200. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPESDR IXXA08SMN086SSkin · crackedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT FUSELAGE TAIL SECTION PLATING CRACKED AT STATION FS 1766.000 TO STATION 1781.000 LONGERON10 LEFT. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. FABRICATED REPAIR SDR IXXA08SMN080SSupport Fitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND FUSELAGE TAIL SKID SUPPORT FITTING CRACKED AT STATION 1734.000 LONGERON36. REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-3-1, DC8 SRM 51-1-20D, DC8 SRM 51-1-8B.SDR IXXA08SMN079SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT WING INBOARD AFT LOWER FLAP SKIN SHOWS DENTS AT STATION XE 2.000 TO STA XE 91.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN, AND DOUBLER. BONDED PARTS AS NEEDED WISDR IXXA08SMN078SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT INBOARD AILERON UPPER SKIN HAS DENT AND NO STANDARD REPAIR AT STATION XA 580.000 TO XA 610.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN, AND DOUBLER. BONDED PARTSDR IXXA08SMN077SFrame · crackedDURING ROUTINE C CHECK INSPECTION, FOUND FORWARD CARGO COMPARTMENT FRAME LOWER FLANGE CRACKED AT STATION 480.000 LONGERON 34 RIGHT. REMOVED DAMAGED AREA. FABRICATED NEW FRAME SEGMENT, SPLICES, ANGLES. HEAT TREATED EXTRUSION FRAME SEGMENT. CLEANED, TREATED,SDR IXXA08SMN076SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND ELEVATOR LEFT UPPER SKIN SHOWS DENTS AND CORROSION AT DIFFERENT POINTS AT STATION XE 146.000 AND XE 270.000. REMOVED CORROSION. FOUND TO BE OUT OF LIMITS. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGSDR IXXA08SMN075SSkin · misrepairedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING CENTER LEADING EDGE LOWER OUTER SKIN SHOWS IMPROPER REPAIR AT STATION XOLDI 6.2246. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION. SDR IXXA08SMN074SSkin · misrepairedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT WING CENTER LEADING EDGE LOWER OUTER SKIN SHOWS IMPROPER REPAIR AT STATION XFS 304.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSP. NO CRASDR IXXA08SMN072SSkin · scratchedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT ELEVATOR UPPER SKIN SHOWS SCRATCHES AT STATION XE 273.000 TO STATION XE 283.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN, FINGER DOUBLER. BONDED PARTS AS NEEDED SDR IXXA08SMN073SFlap · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBD FLAP UPPER PART SHOWS DENTS AT STATION XF 375.000 TO STA XF 404.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN, DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. SDR IXXA08SMN070SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO INTERCOSTAL END CLIP CRACKED AT STATION 857.000 LONGERON 18 RIGHT. REMOVED CRACKED INTERCOSTAL END CLIP. FABRICATED INTERCOSTAL END CLIP. PERFORMED HEAT TREATMENT. CLEANED, TREATED AND PRIMED AREA AND INTSDR IXXA08SMN047SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND AFT ACCESSORY COMPARTMENT FITTING CRACKED AT STATION 1690.000 LONGERON 28 RIGHT. REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW SRM 51-1-21, SRM 51-3-1, SRM 51-1-20D, AND SRM 51-SDR IXXA08SMN071SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND RIGHT OUTBOARD FLAP LOWER AFT SKIN HAS DENTS AT STATION XF 434.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED AREA. FABRICATED NEW SKIN AND DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANED, SDR IXXA08SMN065SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBOARD FLAP LOWER SKIN FORWARD SHOWS DENTS BETWEEN STATION XF 160.000 - XF 213.000. PERFORMED DETAILED VISUAL INSPECTION. NO CRACK NO CORROSION FOUND. PERFORMED MEASUREMENT DIA 2.00 BY 0.008" DEPTH WITHIN PERMSDR IXXA08SMN067SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT FITTING CRACKED AT STATION 847.000 LONGERON1. REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA AND FITTING. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-1-8-B, DC8 SRM 51-1-2SDR IXXA08SMN63SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBOARD FLAP LOWER SKIN SHOWS DENTS AT STATION XF 434.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN, AND DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANED TREASDR IXXA08SMN062SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO FITTING CRACKED AT STATION 680.000 LONGERON 11 RIGHT. REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-0, DC8 SRM 51-1-21, AND DC8 SRM 51-SDR IXXA08SMN061SFitting · corrodedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT FITTING CORRODED AT STATION 960.000 TO STATION 980.000 LEFT BUTTOCKS LINE 45. REMOVED CORRODED FITING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-3SDR IXXA08SMN066SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO COMPARTMENT FITTING CRACKED AT STATION 690.000 LONGERON 1. REMOVED CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW DC8 SRM 51-1-20D, DC8 SRM 51-3-1, AND DC8 SRM 51-1-8B.SDR IXXA08SMN064SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBOARD FLAP LOWER SKIN DENTS AT STATION XF 169.000 - XF 213.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGED SKIN. FABRICATED NEW SKIN, AND DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CLEANSDR IXXA08SMN054SSkin · scratchedDURING ROUTINE C CHECK INSPECTION, FOUND LEFT OUTBOARD AILERON LOWER SKIN SCRATCHED BETWEEN STATION XA 737.000 AND XA 763.000. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE SKIN. FABRICATED NEW SKIN AND DOUBLER. BONDED PARTS AS NEEDED WITH SDR IXXA08SMN053SSupport Angle · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO FORMER CRACKED AT STATION 1766.000 LONGERON1. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. PERFORMED STOP HOLE ON END CRACK. FABRICATED ANGLE DOUBLER. PERFORMED HEAT TREATMENT CLEANED, TREATED AND PRIMESDR IXXA08SMN052SFitting · crackedDURING ROUTINE C CHECK INSPECTION, FOUND MAIN CARGO FITTING CRACKED AT STATION 680.000 LONGERON 20 RT. REMOVE CRACKED FITTING. CLEANED, TREATED AND PRIMED AREA. INSTALLED NEW FITTING IAW SRM 51-3-1, SRM 51-1-20D, AND SRM 51-1-8B.SDR IXXA08SMN058SSkin · dentedDURING ROUTINE C CHECK INSPECTION, FOUND RUDDER RIGHT SKIN SIDE DENTED AT STATION ZR 276.531 TO ZR 267.218. REMOVED FASTENERS AS NEEDED TO PERFORM REPAIR. REMOVED DAMAGE PANEL PLATING. FABRICATED NEW SKIN AND DOUBLER. BONDED PARTS AS NEEDED WITH HYSOL. CL
Back to N822BX, cancelled May 1, 2014