Service difficulty reports · 15
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model.
SDR R61A20100447Seat Track · corrodedWHILE AIRCRAFT WAS IN FOR HEAVY CHECK, LEVEL 2 CORROSION WAS FOUND ON THE LT SEAT TRACK BEAM AT FRAME 19. MAINTENANCE PERFORMED MAJOR REPAIR ON THE LT SEAT TRACK BEAM IAW EMB ETD2010-170/07857 REV A. REFERENCE PO 180901 FOR MATERIAL USED. A/C IS CURRENTLY SSDR R61A2010435Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON CENTER SHEAR PANEL AT FR87-88 FLOOR CROSS BEAMS. MX REPLACED CENTER SHEAR PANEL IAW EMB 170 SRM. P/N 170-65928, A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A2010434Service Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON INTERNAL SIDE OF WASTE DRAIN BOX STRAP FWD LOWER SLIDE FLANGE. MX REPLACED WASTE DRAIN SERVICE BOX IAW EMB 170 SRM. A/C REMAINS IN HEAVY CHECK FOR COMPLETION P/N 170-65078-403.SDR R61A2010433Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SHEAR PANEL ON LT SIDE AT FR87-88 FLOORBEAMS. MX REPLACED LT SHEAR PANEL P/N 170-65927-007, IAW EMB 170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A2010432Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT SHEAR PANEL AT FR87-88 FLOOR CROSSBEAM. MX REPLACED RT SHEAR PANEL IAW EMB 170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION. P/N 170-91919-001.SDR R61A2010431Gusset · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL FR90 CROSSBEAM TO LT INTERCOSTAL. MX REPLACED GUSSET PLATE IAW EMB 170 SRM. P/N 170-60261-001 A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100429Floorbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT LONGITUDINAL FLOORBEAM BETWEEN FR 85 AND FR 90. MX REPLACED THE RT UPPER SHEET FLOORBEAM AND PANEL SUPPORT P/N 170-86101-001, P/N 170-86150-001, P/N 170-65669-004 IAW EMB 170 SRM. A/C REMAINS IN SDR R61A20100439Gusset · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL ON FR90 CROSSBEAM ON RT SIDE. MX REPLACED GUSSET PLATE P/N 170-60259-001 IAW EMB 170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100438Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL AT FR90 TO RT LONGITUDINAL BEAM. MX REPLACED SPLICE PANEL ON RT FR90 IAW EMB 170 SRM P/N 170-60258-001. A/C REMAINS IN CMH TO COMPLETE HEAVY CHECK.SDR R61A20100437Panel · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON SPLICE PANEL ON FR90 CROSSBEAM TO LT LONGITUDINAL BEAM. MX REPLACED SPLICE PANEL P/N 170-60257.001 IAW EMB170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100436Floor Support · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON LT CENTER FLOOR SUPPORT AT FR 18 CROSS BEAM. MX REMOVED DAMAGE INSTALLED FILLER AND DOUBLER IAW EMB ETD 2010-170/07857 DATED 9-2-10 BEAM P/N 170-03264-001. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETSDR R61A20100428Floorbeam · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON LT LONGITUDINAL FLOORBEAM BETWEEN FR85 AND FR 90. MX REPLACED LT LONGITUDINAL FLOORBEAM P/N 170-65669-03 IAW EMB 170 SRM. A/C REMAINS IN CMH FOR HEAVY CHECK COMPLETION.SDR R61A20100427Floor Support · corrodedWHILE A/C WAS IN FOR HEAVY CHECK FOUND LEVEL 2 CORROSION ON RT CTR FLOOR SUPPORT FROM FR 14 TO FR 18 CROSS BEAMS. MX REPLACED RT CTR FLOOR SUPPORT P/N 170-03263-001 FROM FR14 TO FR 18 IAW EMB 170 SRM. A/C REMAINS IN CMH FOR COMPLETION OF HEAVY CHECK.SDR R61A20100080Steering Sys · malfunctionedCREW REPORTED A STEER FAIL DURING LANDING GEAR EXTENSION, DECLARED EMERGENCY INTO MCI AND LANDED WITHOUT INCIDENT. MAINTENANCE WAS DISPATCHED TO THE A/C, AND TROUBLESHOT PER EMB 32-53-00-810-806-A AND RESET THE NWS CB PER EMB AMM AND THE FAULT CLEARED, THE A/SDR 200705071Pump · malfunctionedFLIGHT 6451 MEM TO ATL ON THE TAKEOFF ROLL AS POWER WAS APPLIED, CREW RECEIVED A BLUE CREW AWARENESS EICAS MESSAGE, FUEL 2 FEED FAULT. THE TAKEOFF WAS ABORTED AT ABOUT 10 KNOTS. MAINTENANCE ADVISED THE CREW TO CYCLE A/C PUMP 2. CREW COMPLIED. SYSTEM OPS CH