N915FR, cancelled Mar 6, 2009
Service difficulty reports · 50
Matched to this aircraft by N-number and event date, checked against the reported serial number, make and model. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N915FR' AND deregistration_id = 'N915FR-2009-03-06' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N915FR' AND deregistration_id = 'N915FR-2009-03-06' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA200800545Floor Panel · damagedLINE MECHANIC NOTED THE AFT CARGO PIT TRANSITION PANEL 151AE WAS DAMAGED. MAINT REPAIRED DAMAGED PANEL 151AE IAW SRM 53-02-00, STEP 2, FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (S)SDR F3LA200800343Proximity Switch · failedREFERENCE NON ROUTINE C045163. DURING C4 S1 C-CHECK INSPECTION NOTED CHECK DOOR SWITCH POWER SUPPLIED BY EMERGENCY LIGHT SYSTEM FAILS AT PAGE 4 STEP 3, WORK CARD C335004-2 FOR THE FORWARD DOORS AND WORK CARD C335004-2 AT PAGE 6 STEP 8 FOR THE L1 DOOR. MAINTESDR F3LA200800334Frame · corrodedDURING C-CHECK INSP NOTED AFT CARGO FLOOR FRAME 59 HAS CORROSION AT NUTPLATE HOLES. MAINT REPAIRED HOLES WITH REPAIR DOUBLERS IAW EA A9-53R-30346. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A) THE PERMANENT REPAIR FOR CORROSION DAMSDR F3LA200800333Sill · corrodedDURING C-CHECK INSP, NOTED UPON CLOSURE OF AFT PIT CORROSION WAS FOUND ON THE SILL WEDGE PANEL 152YG. MAINT INSTALLED A NEW PANEL IAW WORK CARD CP753-25. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800332Plate · corrodedDURING C-CHECK INSP, NOTED L1 DOOR GIRT BAR PLATE ON SILL IS CORRODED. MAINT REMOVED OLD GIRT BAR PLATE, FABRICATED NEW PLATE AND INSTALLED NEW GIRT BAR PLATE IAW DRAWING 351-1234 AND SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCSDR F3LA200800326Floor Panel · damagedREFERENCE NON ROUTINE C44993. DURING C4 S1 C-CHECK INSPECTION NOTED AFT PIT FLOOR PANEL 151VG HAS A 2 INCH SECTION MISSING ON TOP PIECE SHOWING COMPOSITE ALONG EDGE. MAINTENANCE CUT OUT DAMAGE, TRIMMED CORE, INSTALLED NEW CORE AND REPAIRED LOWER SKIN FLOOR PSDR F3LA200800325Profile · corrodedREFERENCE NON ROUTINE C044887. DURING C4 S1 C CHECK INSPECTION NOTED AFT CARGO COMPARTMENT FLOOR FRAME CAP AT FRAME 59 FROM STRINGER 38 LT TO STRINGER 38 RT IS CORRODED. MAINTENANCE REMOVED FRAME 59 PROFILE, UPSIZED AND COUNTERSUNK HOLES AS REQUIRED, INSTALLSDR F3LA200800324Floorbeam · corrodedREFERENCE NON ROUTINE C044879. DURING C4 S1 C-CHECK INSPECTION NOTED AFT CARGO COMPARTMENT STANCHION RECEPTABLE AND AREA CORRODED AT FLOOR FRAME 56 AND STRINGER 37 RT. MAINTENANCE REPAIRED IN ACCORDANCE WITH EA A9-53R-30365 AND SRM 51-42-11, SRM 51-75-12, SRSDR F3LA200800323Floorbeam · corrodedREFERENCE NON ROUTIN C044731. DURING C4 S1 C-CHECK INSPECTION NOTED CORROSION ON OUTBOARD NUT CLIP HOLE 2 INCHES FORWARD OF FRAME 66 ON FLOORBEAM Y1732 LT. MAINTENANCE REPAIRED FLOORBEAM Y1732 LT IN ACCORDANCE WITH THE REQUIREMENTS OF EA A9-53R-30354, SRM 51SDR F3LA200800322Profile · corrodedREFERENCE NON ROUTINE C044450. DURING C4 S1 C-CHECK INSPECTION NOTED FORWARD CARGO PIT PROFILE FOR LOWER AFT BULKHEAD HAS CORROSION IN NUT PLATE HOLES FROM STRINGER 28 LT TO STRINGER 28 RT. MAINTENANCE REMOVED AND REPLACED PROFILE AT STRINGER 28 LT TO STRINGSDR F3LA200800321Floor Panel · corrodedREFERENCE NON ROUTINE C044794. DURING C4 S1 C-CHECK INSPECTION NOTED PANEL 221FF HAS LITE CORROSION ON BOTTOM SIDE. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL 221FF IN ACCORDANCE WITH THE REQUIREMENTS OF WORK CARD SP753-12. UPON COMPLETION OF THE REPAIR, SDR F3LA200800320Floor Panel · corrodedREFERENCE NON ROUTINE C044797. DURING C4 S1 C-CHECK INSPECTION NOTED PANEL 222FF HAS SEVERE CORROSION ON BOTTOM SIDE. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF WORK CARD CP753-12. UPON COMPLETION OF THE REPAIR IT WASDR F3LA200800319Floor Panel · corrodedREFERENCE NON ROUTINE C044808. DURING C4 S1 C-CHECK INSPECTION NOTED PANEL 222EF SPLICE PLATE CORRODED. MAINTENANCE REMOVED AND REPLACED FLOOR PANEL SPLICE PLATE IN ACCORDANCE WITH THE REQUIREMENTS OF WORK CARD CP753-12. UPON COMPLETION OF THE REPAIR, IT WASDR F3LA200800318Floorbeam · corrodedREFERENCE NON ROUTINE C044885. DURING C4 S1 C-CHECK INSPECTION NOTED AFT CARGO COMPARTMENT FLOOR FRAME 59 U-CHANNEL IS CORRODED FROM STRINGER 41 RT TO STRINGER 38 LT. MAINTENANCE REMOVED AND REPLACED U-CHANNEL IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-44SDR F3LA200800302Seat Track · corrodedREFERENCE NON ROUTINE C044835. DURING C4 S1 C-CHECK INSPECTION NOTED CORROSION ON SEAT TRACK AT Y1292 BETWEEN FRAME 19 AND FRAME 20. MAINTENANCE REMOVED AND REPLACED BEAM IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11. UPON COMPLETION OF THE REPAIR IN SDR F3LA200800301Profile · corrodedDURING C4 S1 C-CHECK INSP, NOTED AFT CARGO COMPARTMENT LT FLOOR PROFILE IS CORRODED FROM FRAME 51 TO FRAME 56 AT STRINGER 38 LT. MAINT REMOVED AND REPLACED LT HAND FLOOR PROFILE IAW SRM 51-42-11 PARAGRAPH 5. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED ANDSDR F3LA200800300Floorbeam · corrodedDURING C-CHECK INSP, NOTED CORROSION ON FLOOR TRACK AT Y189 FRAME 20. MAINT REMOVED DAMAGED FLOORBEAM Y189 AND INSTALLED NEW FLOORBEAM FROM FRAME 20 TO FRAME 24 IAW SRM 51-42-11 PARAGRAPH 7. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLESDR F3LA200800317Panel · puncturedREFERENCE NON ROUTINE C044396. DURING C4 S1 C CHECK INSPECTION NOTED AFT PIT TRANSITION PANEL 151AE HAS PUNCTURE DAMAGE. MAINTENANCE REMOVED DAMAGE, CLEANED PANEL AND REPAIRED PUNCTURE DAMAGE IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-02-00 FIGURE 204. USDR F3LA200800294Floorbeam · corrodedDURING C-CHECK INSP NOTED THE CENTER LONGITUDINAL FLOORBEAM FROM FRAME 58 TO FRAME 59 HAS CORROSION AROUND THE FWD NUTPLATE HOLE. MAINT REPAIRED THE FLOORBEAM IAW EA A9-53R-30355 AND SRM 51-75-00, SRM 53-00-14 AND SRM 51-42-11. UPON COMPLETION OF THE REPAIR ITSDR F3LA200800299Floor Panel · corrodedDURING C-CHECK INSP, NOTED AFT PIT FLOOR PANEL 151PE HAS SURFACE CORROSION AROUND ATTACHMENT HOLES AND EDGES. MAINT CLEANED CORROSION, FILLED COUNTER SINK AREA, PREPPED AND PRIMED PANEL 151PE IAW DRAWING 319-53-0001-11 AND AMM 25-00-00-870-001. UPON COMPLETIOSDR F3LA200800297Floor Panel · puncturedDURING C-CHECK INSP NOTED FLOOR PANEL 231XG HAS TWO SMALL PUNCTURE HOLES ON SURFACE. MAINT REPAIRED PUNCTURE DAMAGE TO FLOOR PANEL 231XG IAW SRM 53-02-00 STEP 8A. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800296Floor Panel · delaminatedREFERENCE NON ROUTINE C045066. DURING C4 S1 C CHECK INSPECTION NOTED FLOOR PANEL 221BF HAS DELAMINATION AROUND SCREW HOLES. MAINTENANCE REMOVED DELAMINATED AREA AND APPLIED MOISTURE BARRIER FOIL IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 53-02-00 PAGE 245 FISDR F3LA200800298Fitting · corrodedDURING C-CHECK INSP, NOTED L2 DOOR AFT TOP SLIDE ATTACH POINT BRACKET CORRODED. MAINT REMOVED CORRODED FITTING AND INSTALLED SERVICEABLE FITTING IAW SRM 51-42-11 PARAGRAPH 5, AMM 20-21-11-911-01 AND AMM 20-21-11-991-003 SHEET 203. UPON COMPLETION OF THE REPASDR F3LA200800295Floor Panel · damagedDURING C-CHECK INSP NOTED FLOOR PANEL 251JG HAS DAMAGE IN TWO PLACES ON UPPER SURFACE. MAINT REMOVED DAMAGE AND APPLIED MOISTURE BARRIER IAW SRM 53-02-00 AND SRM 53-02-00. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800293Floorbeam · corrodedDURING C-CHECK INSP NOTED CORROSION ON BEAM Y1292 LT UPPER OB SIDE NUTCLIP HOLE AT FRAME 68. MAINT REMOVED CORRODED FLOORBEAM Y1292 AND INSTALLED NEW FLOORBEAM FROM FRAME 68 TO FRAME 69 IAW SRM 51-42-00 AND DRAWINGS D53472780, D53472816 AND E53473250. UPON COMSDR F3LA200800285Panel · dentedDURING C-CHECK INSP, NOTED AFT PIT TRANSITION PANEL 161BF HAS A DENTS. MAINT REMOVED DAMAGE AND CLEANED PANEL, FILLED DENTS ON PANEL 161BF IAW SRM 51-73-00 STEP 3C. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800292Panel · damagedDURING C4 S1 C-CHECK INSPECTION NOTED AFT PIT TRANSITION PANEL 162BF HAS DENTS. MAINT REMOVED DAMAGE AND CLEANED PANEL FILLED DENTS ON PANEL 162BF IAW SRM 53-02-00. STEP 3C. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800291Panel · damagedDURING C-CHECK INSP NOTED AFT PIT TRANSITION PANEL 162CF HAS DENTS AND GOUGES. REMOVED DAMAGE AND CLEANED PANEL FILLED DENTS AND REPAIRED PUNCTURE DAMAGE IAW SRM 51-73-00 STEP 3C AND SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FSDR F3LA2008290Panel · damagedDURING C-CHECK INSP, NOTED FWD PIT TRANSITION PANEL 131BF HAS GOUGE IN CORE. MAINT REMOVED DAMAGE AND CLEANED PANEL REPAIRED PUNCTURED DAMAGE PANEL 131BF IAW SRM 53-02-00 FIGURE 204. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800289Panel · dentedDURING C-CHECK INSP NOTED AFT PIT TRANSITION PANEL 151HE HAS DENTS. MAINT REMOVED DAMAGE AND CLEANED PANEL FILLED DENTS ON PANEL 151HE IAW SRM 53-73-00 STEP 3C. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800288Floorbeam · corrodedDURING C-CHECK INSP, NOTED FLOORBEAM 1292 RT AT FRAME 68 CORROSION IN OB NUTCLIP HOLE. MAINT INSTALLED NEW FLOORBEAM Y1292 FROM FRAME 68 TO FRAME 69 IAW THE REQUIREMENTS OF SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800287Panel · dentedDURING C-CHECK INSP, NOTED AFT PIT TRANSITION PANEL 151FE HAS DENTS. MAINT REMOVED DAMAGE AND CLEANED PANEL, FILLED DENTS, PANEL 151FE IAW SRM 51-73-00 STEP 3C. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800286Beam · corrodedREFERENCE NON ROUTINE C044730. DURING C4 S1 C-CHECK INSPECTION NOTED CORROSION ON UPPER SURFACE OF Y1292 RT BEAM 7 INCHES FORWARD OF FRAME 68. MAINTENANCE REMOVED OLD BEAM Y1292 AND INSTALLED NEW BEAM IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11. UPOSDR F3LA200800284Panel · delaminatedDURING C4 S1 C-CHECK INSP NOTED FWD PIT TRANSITION PANEL 32DG HAD A CORNER DELAMINATED. MAINT CLEANED DAMAGED AREA AND REPAIRED DAMAGE IAW SRM 53-02-00 PAGE 209. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800283Floorbeam · corrodedDURING C-CHECK INSP, NOTED FLOORBEAM Y765 RT HAS PITTING CORROSION AT FRAME 68 ON TOP SURFACE. MAINT REMOVED BEAM AND INSTALLED NEW BEAM IAW DRAWING D53472815 AND SRM 51-42-11. UPON COMPLETION OF THE REPAIR IT WAS INSPECTED AND FOUND ACCEPTABLE. (A)SDR F3LA200800282Support · corrodedDURING C-CHECK INSP, NOTED THE SUPPORT FRAME FOR SHEAR PLATE CORRODED ON BOTTOM SURFACE AT NUTCLIP HOLES LOCATED AT THE LT OB SIDE AT FRAME 70. MAINT REMOVED CORRODED SUPPORT FRAME AND INSTALLED NEW SUPPORT FRAME IAW SRM 51-42-11 AND SRM 51-44-11. UPON COMPLSDR F3LA200800281Frame · corrodedDURING C4 S1 C-CHECK INSPECTION NOTED SUPPORT FRAME FOR SHEAR PLATE CORRODED ON BOTTOM SURFACE AT NUT CLIP HOLE. MAINTENANCE REMOVED OLD SUPPORT FRAME AND INSTALLED A NEW SUPPORT FRAME IN ACCORDANCE WITH THE REQUIREMENTS OF SRM 51-42-11 PARAGRAPH 6 AND 7. UPSDR F3LA200700219Warning Light · false activationAIR TURN BACK AT 1244, FLIGHT CREW REPORTED VENT EXTRACT FAULT. AIRCRAFT RETURNED TO KMDW AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AIRCRAFT AND PERFORMED OPS SYSTEM TEST VIA MCDU. NO DISCREPANCIES NOTED. AIRCRAFT OKAY FOR SERVICE IAW AMM 21-26-00SDR F3LA200700011Cylinder Damper · failedWHILE PERFORMING OPS TEST OF SLIDE DEPLOYMENT PER TC 25830-1, L1 DOOR ASSIST BOTTLE DID NOT FULLY OPEN DOOR TO DEPLOY SLIDE. REPLACED L1 DOOR CYLINDER DAMPER ASSY IAW MM 52-11-14-000-001 AND 52-11-14-400-001, PARA 4 A-D AND 5 A-C. SERVICED AND PERFORMED PRESSDR F3LA200600156Longeron · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION AT LONGERON Y1292, 14 FT AFT OF FR67. REMOVED CORROSION FROM AREA AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-14. FINISHED BURNISHMENT AND NEEDED HFEC CHECK FOR CRACKS IN REFERENCE TO EA A9-53R-11651. PERFORMEDSDR F3LA200600155Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED 2ND FLOORBEAM IB OF R2 DOOR HAD MULTIPLE AREAS OF CORROSION AROUND NUTPLATE HOLES. REMOVED CORROSION AND FOUND 3 AREAS TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102, AS FOLLOWS: 2.0 INCHES FWD OF FR67 ON LONGERON Y765; SDR F3LA200600154Threshold · corrodedDURING C-3 CHECK, INSPECTION REPORTED CORROSION ON BOTTOM OF L2 DOOR THRESHOLD PLATE. REPLACED L2 DOOR THRESHOLD PLATE IAW TASK CARD C252001-22.SDR F3LA200600153Floor Panel · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOOR PANEL 262FF CORRODED. REPLACED FLOOR PANEL 262FF PER AMM 53-42-12-400-002.SDR F3LA200600152Floor Panel · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOOR PANEL 261FF CORRODED. REPLACED FLOOR PANEL 261FF PER AMM 53-42-12-400-002.SDR F3LA200600151Bottle · brokenDURING C-3 CHECK, INSPECTION REPORTED RT. OVERWING RESERVOIR INFLATION CABLE IN AFT PIT HAD TIP BROKEN OFF THAT HOOKS TO THE FLEX RELEASE CABLE. REPLACED OVERWING SLIDE BOTTLE IN RT AFT PIT IAW AMM 25-62-46-400-001.SDR F3LA200600150Floorbeam · corrodedDURING C-3 CHECK, INSPECTION REPORTED FLOORBEAM IB OF L2 DOOR HAD MULTIPLE AREAS OF CORROSION LOCATED AROUND NUTPLATE HOLES. REMOVED CORROSION AND DETERMINED TO BE OUT OF LIMITS IAW SRM 53-00-14, FIG. 102. DAMAGE LOCATED 6.5 INCH AFT OF FRAME 67 ON THE STUB SDR F3LA200500036Warning Light · illuminatedUPON APPROACH, FLIGHT CREW REPORTED F/CTL FLAPS FAULT WHEN SELECTING FLAPS TWO. FLAPS STAYED AT ZERO. DECLARED AN EMERGENCY. AIRCRAFT LANDED WITHOUT INCIDENT. PERFORMED ROUTINE TROUBLESHOOTING OF FLAPS AND SLATS PER AMM 27-81-00-740-002. NO CURRENT FAULTS.SDR F3LA200500030Flap System · malfunctionedDURING ARRIVAL IN ANC, FLIGHT CREW REPORTED FLT CONTROL FLAPS FAULT ON ECAM. SLATS TRAVELED TO THE 2 POSITION, FLAPS DID NOT MOVE FROM THE ZERO POSITION. AIRCRAFT LANDED WITHOUT INCIDENT. PERFORMED BITE TEST OF SFCC 1 AND SFCC 2. NO FAULTS NOTED. OPERATEDSDR F3LA200500020Computer · inoperativeFLIGHT CREW REPORTED ELAC 2 FAULT. ON SHORT FINAL LOST BOTH AILERONS WENT TO DIRECT LAW. REPLACED NR 2 ELAC. OPERATIONAL CHECK GOOD PER MM 27-93-34, PAGE 401. PERFORMED LAND CAT 3 TEST, OPS CHECK GOOD PER MM 22-97-00-710-001. UMP STATUS REMAINED CAT 3B. SDR F3LA200300120Switch · faultyABORTED TAKEOFF DUE TO REFUELING PANEL INDICATION. PERFORMED BRAKE INSPECTION IAW AMM 05-51-16-06. NO DEFECTS NOTED. REPLACED REFUELING PANEL DOOR SWITCH 20QJ IAW AMM 52-42-18-820-050 AND SYSTEM CHECKED NORMAL.
Back to N915FR, cancelled Mar 6, 2009