SDR QXEA2012111301382Engine · bird ingestionON LANDING ROLLOUT AT 60 KNOTS, RT ENGINE INGESTION. PROPS WERE AT DISC. NR 2 AC GEN CAUTION WITH VERY STRONG BURNING ODOR. SELECTED NR 2 BLEED OFF AND ODOR STOPPED. AC GEN CAME BACK ON APROX 2 MIN AFTER STRIKE. REPLACED NR 2 ENGINE. RETURNED TO SERVICE.SDR CA121119019Breather Tube · leaking(CAN) DURING DESCENT, THE OIL TEMPERATURE WENT UP FOLLOWED BY LOW OIL PRESSURE WARNING. THE ENGINE WAS SHUTDOWN AND AN UNEVENTFUL SINGLE ENGINE LANDING WAS ACCOMPLISHED POST FLIGHT INSPECTION FOUND OIL EXITING THROUGH THE BREATHER TUBE. TROUBLESHOOTING IS ON-SDR CA121113003Windshield · cracked(CAN) CRACK OCCURRED ON RT WINDSHIELD OUTER GLASS PLY. NEXT SERVICE FLIGHT WAS DELAYED. DAMAGED WINDSHIELD REPLACED.SDR CA121112007Brake · failed(CAN) CREW SAID THAT THEY LOST ALL FLUID IN NR 2 SYSTEM HYDRAULICS WHILE ON THE DEICE PAD. ACFT WAS JUST TOWED BACK TO THE GATE AND MAINTENANCE IS CHECKING TO SEE WHAT THE ISSUE IS. MAINTENANCE REPORTS THAT THE NR 1 BRAKE IS FALLING APART, AND THE WHEEL ASSYSDR CA121115003Hose · failed(CAN) PILOT REPORTED A HYDRAULIC LEAKAGE IN THE NOSE WHEEL WELL AREA. FOUND THE NLG DOWNLOCK ACTUATOR HYDRAULIC FLEXIBLE HOSE BURSTED. HOSE , REPLACED.SDR CA121108001Generator · malfunctioned(CAN) DURING TAKE OFF, AN OPERATOR HAD A NR 2 AC GENERATOR CAUTION FOLLOWED BY A NR 2 AC GENERATOR HOT CAUTION LIGHT. THE AC GENERATOR WAS SELECTED OFF. PILOT THEN NOTICED A NR 2 OIL LOW PRESSURE WARNING AND VERIFIED THAT THE OIL PRESSURE GAUGE WAS REDUCING TOSDR CA121116007Torque Tube · chafed(CAN) DURING REPLACEMENT OF LT ELEVATOR TORQUE TUBE ASSY IAW AD CF 2010-27-PTA, CHAFE DAMAGE WAS FOUND ON THE TUBE. DAMAGE IS LOCATED 11.75" FROM THE OTBD END OF THE TUBE, IT IS .030" DEEP AND .280" LONG. DAMAGE WAS CAUSED BY AN INTERFERING LOCKWIRE SEAL FROSDR CA121119004Oil System · low pressure(CAN) DURING CLIMB, A LOW OIL PRESSURE WARNING OCCURRED. THE PILOT ELECTED TO SHUT THE ENGINE DOWN AND RETURN TO THE DEPARTURE AIRPORT WHERE AN UNEVENTFUL SINGLE ENGINE LANDING WAS ACCOMPLISHED. POST FLIGHT INSPECTION FOUND AN OIL FILTER BYPASS. THE ENGINE SDR CA121106001Bearing · failed(CAN) DURING ROLLOUT FOLLOWING A NORMAL LANDING, THE NR 3 WHEEL SEPARATED FROM MLG. THE WHEEL OVERTOOK THE ACFT AND FINALLY CAME TO A REST IN THE GRASS AREA. THE ACFT WAS STOPPED BEYOND THE STOP BARS CLEAR OF THE RUNWAY. GROUND WAS ADVISED. ACCORDING TO MAISDR CA121108002Pump · failed(CAN) AN OPERATOR REPORTED THAT DURING FLIGHT THEY EXPERIENCED A RAPID HYDRAULIC LOSS FROM SYSTEM NR 2 AND AFTER LANDING THERE WAS AROUND 25 PERCENT REMAINING LEVEL. DURING INSPECTION DISCOVERED THAT HYDRAULIC LEAKAGE FROM EDP NR 2. THE ENGINE SUFFERED HYDRAUSDR QXEA2012103001366Unknown · malfunctionedON CLIMBOUT THROUGH 12,000 FT. POWER PLANT MESSAGE APPEARED ON ENGINE DISPLAY. RETURNED TO FIELD AND ACCOMPLISHED A UNEVENTFUL LANDING. REPLACED NR 1 FADEC AS A PRECAUTION, REPLACED NR 1 P3 TRANSDUCER, REPLACED NR 2 FADEC HARNESS, REPLACED NR 1 CHARACTERIZASDR QXEA2012102601349Computer · malfunctionedAUTOFEATHER SHOWS FAIL NR 1 ENGINE AND ABORT NR 2 ENGINE DURING SYS TEST. CONFIRMED AUTOFEATHER TEST FAILED. INTEREGATED CDS FOR PROP FAULT CODES-FOUND P-PLANT FAULTS ON NR 2 PROP: CH A-402, 494, AND CH B-294, 400, 402, 408, 494. C/W FIM TASK 61-20-09-810-81SDR CA121026003Wire · broken(CAN) THE CREW RECEIVED A RT REAR SERVICE DOOR WARNING MESSAGE. THE DOOR WAS CYCLED AND THE MESSAGE CLEARED BUT RETURNED LATER. THE DEFECT WAS DEFERRED IAW THE MEL. UPON MAINTENANCE INVESTIGATION A BROKEN WIRE WAS FOUND AT THE RT AFT SERVICE DOOR HINGE ARM SDR CA121025001Shaft · sheared(CAN) ACFT REQUIRED AN ATB DUE TO EDP FAILURE. MAINTENANCE FOUND METAL IN THE CASE DRAIN FILTER AND THE SHAFT OF EDP WAS SHEARED. EDP REPLACED. HYD SYSTEM FLUSHED. A/C RTS.SDR CA121026001Adapter · failed(CAN) TAXIING INTO GATE, A BURNING ODOR WAS NOTICED IN THE CABIN. SMOKE WAS ALSO OBSERVED AT THE RT NACELLE. UPON ARRIVAL, THE ENGINES WERE SHUTDOWN AND PASSENGER DEPLANED NORMALLY. ACFT WAS REMOVED FROM SERVICE AND MAINTENANCE CREW TRAVELED TO THE ACFT LOCATSDR CA121022016Wheel · seized(CAN) OPERATOR REPORTED THAT AFTER LANDING THE ACFT WAS FOUND TO HAVE THE NR 2 NLG TIRE SEIZED. NR 2 NLG BEARINGS SEIZED IAW OPERATORS COMMENTS, DAMAGE ALSO TO AXLE. THE ACFT WAS RTS WITH A SWAPPED AXLE AND NEW NOSE TIRES FROM ANOTHER ACFT.SDR CA121018004Actuator · failed(CAN) ON TAXI OUT FROM GATE FOR A SCHEDULED FLIGHT, THE YAW DAMP DISENGAGED AND Y/D OFF CENTER MESSAGES DISPLAYED ON BOTH PRIMARY FLIGHT DISPLAYS. ACFT TAXIED BACK TO GATE AND THE FLIGHT CREW CONTACTED MAINTENANCE CONTROL. THE CREW RESET THE ASSOCIATED CIRCUSDR CA121016001Bleed Valve · malfunctioned(CAN) NR 2 ENGINE FADEC CAUTION LIGHT ILLUMINATED DURING CRUISE AND THE CREW DECIDED TO RETURN TO THE BASE. FADEC F/C SHOWS MALFUNCTIONING P2.2 HBOV, THE ACFT RTS AFTER REPLACEMENT OF THE SUBJECT VALVE.SDR CA121015006Tire · failed(CAN) DURING T/O, PILOT NOTED NLG SOUND AND BANGING AND THEN PERFORMED ATB. UPON LANDING NOTICED NR 2 NLG TIRE SHREDDED, DAMAGE ON BELLY AND NLG AFT DOOR. TIRE REPLACED AND DAMAGE IS BEING REPAIRED.SDR CA121219008Bearing · failed(CAN) RAMP REPORTED NR 4 TIRE FLAT. MAINTENANCE FOUND NR 4 WHEEL BEARING FAILED. WHEEL, AXLE, AND BRAKE REPLACED.SDR CA121015005Module · faulted(CAN) CREW REJECTED T/O DUE TO WARNING SOUND DURING T/O ROLL AROUND 80KT. THE CREW PERFORMED T/O WARNING SYS CHECK AND CONFIRMED NO SNAG THEN SECOND T/O ATTEMPT WAS MADE HOWEVER THE WARNING SOUND OCCURRED DURING THE T/O AGAIN AROUND 100KT. MAINTENANCE PERFOSDR CA121010005Governor · malfunctioned(CAN) DURING CLIMB, THE NR 1 ENGINE WAS SHUTDOWN DUE LOSS OF OIL. DURING ENGINE RUN LEAK IDENTIFIED FROM BASE OF OVERSPEED GOVERNOR, OSG. OVER SPEED GOVERNOR WAS REPLACED WITH NO FURTHER LEAKS. REVIEWED EMU DATA AND REQUIRE NO ADDITIONAL INSPECTION. SINCE TSDR CA121023002Actuator · failed(CAN) DURING SCHEDULED MAINTENANCE, TECH DISCOVERED NR 2 INTAKE DOOR AND ACTUATOR MISSING FROM ACFT. THE LOWER HINGE HARDWARE WAS MISSING WITH THE COWL SIDE HINGE INTACT, NO DAMAGE. THE ACTUATOR BODY HAD BEEN PULLED APART. ROOT CAUSE UNKNOWN, POSSIBLE MAINTESDR QXEA201209290115Control Switch · malfunctionedAUTOFEATHER WOULD NOT ARM ON TAKEOFF ROLL. SELECT LIGHT WAS ILLUMINATED. ABORTED T/O AT APPROX 50 KNOTS. INTEROGATED CDS AND FOUND FAULT CODE 70A ON NR 1 PROPELLER, FOUND AUTOFEATHER SWITCH STICKING AND NOT LATCHING PROPERLY. REMOVED FUEL/ ENGINE/ PROPELLER CSDR CA121015004Switch · failed(CAN) AUTOFEATHER WOULD NOT ARM ON TAKEOFF. SELECT WAS ILLUMINATED. ABORTED AT 50 KTS. MAINTENANCE FOUND FAULT CODE 70A ON NR 1 PEC DUE TO AUTOFEATHER SWITCH STICKING AND NOT LATCHING CORRECTLY. AUTOFEATHER SWITCH.SDR CA120928003Radome · debonded(CAN) IN THE FLARE FOR LANDING, THE ACFT SUSTAINED A BIRD STRIKE TO THE RT SIDE OF THE RADOME. THERE WAS MINOR DAMAGE TO THE RADOME WHICH REQUIRED ITS REPLACEMENT ON RETURN TO BASE. RADOME, PN 4426X-2-12, SN 1034. ACFT TSN 888, CSN 628.SDR CA121015001Wire Harness · faulty(CAN) NLG UNSAFE LIGHT FLASHING IN FLIGHT. MAINTENANCE FOUND NGLK1 PROXIMATELY SENSOR OPEN FAULT IN PSEU. HARNESS REPLACED.SDR QXEA2012092601101Governor · malfunctionedNR 2 ENGINE SLOW TO COME OUT OF FEATHER DURING START. CHECKED CDS NO FAULTS FOUND. R & R NR 2 OVERSPEED GOVERNOR IAW AMM TASK 61-20-26-00-801/400/801. OPS CHECK GOOD AND NO LEAKS NOTED. OVERSPEED GOVERNOR WAS CHANGED AS PRECAUTIONARY MEASURE. RETURNED TO SSDR CA120927002Fadec · malfunctioned(CAN) PILOT REPORTED NR 2 FADEC FAIL WARNING AT 4000 FT ON DECENT. PILOT FOLLOWED PROCEDURES AND SHUT ENGINE DOWN. PILOT ALSO REPORTED A PROP DE-ICE CAUTION PRIOR TO FADEC FAIL. EMU & FDR DOWNLOADS REQUESTED. FADEC REPLACED.SDR CA121003009Fadec · malfunctioned(CAN) DURING APPROACH, AT FL40, THE NR 2 ENGINE, FADEC FAIL WARNING WAS HEARD FOLLOWED BY A REDUCTION OF POWER TO IDLE AND ENGINE SHUTDOWN. AN UNEVENTFUL SINGLE ENGINE LANDING AT DESTINATION FOLLOWED. TROUBLESHOOTING IS FOCUSING ON A POSSIBLE LOSS OF COMMUNISDR QXEA2012092401100Pitch Control · malfunctionedNR 1 ENGINE PROPELLER DOES NOT APPEAR TO BE COMPLETELY FEATHERED. NOTICED ON PREFLIGHT WALK AROUND. REPLACED NR 1 ENGINE PCU IAW AMM 61-20-11-000-801 AND 61-20-11-400-801. OPS AND LEAK CHECK GOOD. RETURNED TO SERVICE.SDR CA121003001Bracket · cracked(CAN) DURING FINAL APPROACH, THE PILOT HEARD A ENGINE SOUND ACCOMPANIED BY A GENTLE A/C YAW TO RT AND A STRONG ODOR ON THE FLIGHTDECK. BLEEDS WERE SELECTED OFF AND ENG NR 2 ENGINE OIL TEMPERATURE WAS NOTED RISING, FOLLOWED BY A LOW OIL PRESSURE WARNING AND ESDR QXEA2012092101093Frame · chafedCHAFE DAMAGE FROM FIRE EXTINGUISHING LINE CONTACTING NACELLE FRAME LOCATED RT NACELLE BELOW AND AFT OF FWD EXHAUST INBD TRUSS MOUNT BRACKET. BLENDED OUT CHAFE DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BSDR QXEA2012092001089Channel · corrodedFWD GALLEY MOUNT HAT CHANNEL HAS CORROSION IN MULTIPLE AREAS. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREA CRACK FREE, MIN REMAINING THICKNESS .034" REF NDTM 51-00-06-910-801, PT 1 AND 51-00-04-910-801, PT 1. MATERIAL LOSS FOUND TO BE IN SDR QXEA2012092001090Flap Track · crackedLEFT WING, NR 3 LOWER FLAP TRACK HAS MISSING COATING ON ROLLER CONTACT MATING SURFACE AFT END OF TRACK. REMOVED DAMAGE AND FOUND DAMAGE BEYOND LIMITS IAW RD 8/4-57-1511. CONFIRMED BLENDED AREA CRACK FREE REF NDTM 51-00-06-910-801 PT 1. MIN REMAINING THICKNSDR QXEA2012092001092Roller · erodedRT WING NR 2 LOWER FLAP TRACK ROLLER CONTACT SURFACE HAS ERODED, FLAKED COATING. FOUND TRACK TO BE IN LIMITS IAW RD 8/4-57-1907. INSPECTED BLENDED AREA USING HFEC REF NDTM 51-00-06-910-801 PT 1, NO CRACKS NOTED. COMPLIED WITH TASK CARD RD 8/4-57-1907.SDR QXEA2012091901084Skin · corrodedEXTERIOR SKIN UNDER SERVICE DOOR LOWER SCUFF PLATE IS CORRODED. BLENDED AND REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREA CRACK FREE REF NDTM 51-00-01-250-801, PT 6. PERFORMED THICKNESS GRID OF BLENDED AREA, MIN REMAINING THICKNESS .208 RSDR QXEA2012091901085Skin · corrodedLOWER SKIN UNDER TCAS ANTENNA DOUBLER CORRODED. REMOVED CORROSION IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREA CRACK FREE REF NDTM 51-00-01-250-801 PT 6. MATERIAL LOSS FOUND IN LIMITS IAW RD 8/4-53-4795. ALODINED BARE METAL ON EXTERIOR SKIN IAW RD 8/4-53-SDR QXEA2012091901086Hinge · damagedAFT PAX DOOR MAIN HINGE HAS WEAR ON LOWER SURFACE AND BOTH ATTACH POINTS TO FUSELAGE. BLENDED OUT DAMAGE IAW SRM 51-14-00-02-04. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLEND IS WITHIN LIMITS IAW RD 8/4-52-824. APPLIED ALODINE PRISDR QXEA2012091901087Web · corrodedAFT CARGO FLOOR WEB HAS CORROSION BETWEEN FR 701-714 STR 31-24P. REMOVED CORROSION REF SRM 51-21-00-00-02. PERFORMED HFEC OF BLENDS FOR CRACKS IAW NTM 51-00-06-910-801 PT 1, NO CRACKS NOTED. PERFORMED THICKNESS OF BLENDS IAW NTM 51-00-04-910-801 PT 1. MIN SDR QXEA2012091801077Skin · corrodedINTERNAL FUSELAGE SKIN HAS CORROSION BETWEEN FR-39-18.25 STR 32-31S. REMOVED RIVETS AS NECESSARY AND BLENDED CORROSION LIMITED TO SKIN STRAP REF SRM 51-42-05-02-01, AND 51-21-00-00-02. MIN REMAINING THICKNESS NOTED .037", CONFIRMED AFFECTED AREA CRACK FREE RSDR QXEA2012091801088Skin · damagedRT INBD FLAP LOWER SURFACE HAS 9 SMOKING RIVETS. R & R RIVETS IAW SRM 51-42-05-02-01.SDR QXEA2012091801083Skin · damagedRT INBD FLAP LOWER SURFACE HAS 9 SMOKING RIVETS. R & R RIVETS IAW SRM 51-42-05-02-01.SDR QXEA2012091801078Frame · corrodedDURING REMOVAL OF EXISTING REPAIR AT FR ST 301 STR30-31P FOUND CORROSION ON FRAME UNDER REPAIR DOUBLER. REMOVED CROSS BRACE AT STR 30P FOM. REMOVED CORROSION FROM FRAME IAW SRM 51-21-00-00-02. CONFIRMED BLENDED AREAS ARE CRACK FREE REF NDTM 51-00-06-910-801SDR QXEA2012091801079Frame · corrodedFRAME BS 281 AT STRINGER 31P IS CORRODED. REMOVED CORROSION ON FWD AND AFT SIDE OF FRAME IAW SRM 51-41-05-00-01, 51-42-05-02-01 AND 51-21-00-00-02. VERIFIED BLENDS CRACK FREE IAW NTM 51-00-06-910-801 PT 1. MEASURED REMAINING THICKNESS OF BLENDS IAW NTM 51-00SDR QXEA2012091801080Seat Track · damagedSEAT TRACK NR 2, MULTIPLE AREAS OF CORROSION OR OTHER DAMAGE. REMOVED CORROSION ON SEAT TRACK IAW RD 8/4-53-884. SEAT TRACK NR 2 FOUND TO BE OUT OF LIMITS IAW RD 8/4-53-884. CONFIRMED AFFECTED AREA CRACK FREE REF NTM 51-00-06-910-801 PT 1. BLENDED AREA WITSDR QXEA2012091801081Connector · corrodedCONNECTOR AT CROSSOVER PANEL AT FRAME -18.25 CL HAS CORROSION, WITH POSSIBLE CORROSION ON NUMEROUS BACKSHELLS AND PLUGS. REMOVED CORROSION FROM CROSSOVER PANEL REF SRM 51-21-00-00-02. CLEANED ELECTRICAL CONNECTORS REF AMM 20-30-03-910-801. ALUMA PREP AND ALSDR QXEA2012091701064Skin · damagedFUSELAGE SKIN HAS FRETTING DAMAGE AROUND PERIMETER OF RT ICE SHIELD. REMOVED 7 RIVETS FROM AFT PERIMETER OF RT ICE SHIELD IAW SRM 51-42-05-02-01. REMOVED FRETTING DAMAGE ON SKIN IAW SRM 51-14-00-02-03. MIN REMAINING THICKNESS .035" REF NDTM 51-00-02-250-801SDR QXEA2012091701066Threshold · corrodedSERVICE DOOR THRESHOLD FWD CORNER HAS CORROSION. REMOVED THRESHOLD CHANNEL AND ASSOCIATED PARTS FOM IAW SRM 51-42-05-02-01, 51-40-15-02-01 AND 51-41-00-00-01. FOUND TO BE OUT OF LIMITS IAW SRM 53-40-21-00-01. MATCH DRILLED NEW THRESHOLD CHANNEL IAW SRM 51-4SDR QXEA2012091701070Nut Plate · corrodedCO PILOTS LOWER WINDOW SILL NUT PLATES CORRODED AND LOOSE. REMOVED 7 NUTPLATE CLIPS FROM LOWER WINDOW SILL IAW SRM 51-42-05-02-01. R & R 21 NUTPLATES IAW SRM 51-42-35-02-01. INSTALLED NUT PLATE CLIPS IAW SRM 51-42-05-02-01. ALODINED AND PRIMED FASTENERS AN
Back to Pratt & Whitney Canada PW150A