Pratt & Whitney JT8D-9
Service difficulty reports · 686
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D9' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE engine_model_key = 'JT8D9' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1100689855Attach Fitting · crackedAFT CARGO COMPT STA 1167 AT L28R FRAME TO INTERCOSTAL ATTACH FITTING CRACKED. REMOVED CRACKED ATTACH FITTING AND REPLACED IAW SRM 51-30-5. LOCATED DRILLED AND DEBURRED IAW SRM 51-10-4.SDR DALA1100699855Skin · crackedFUSELAGE EXTERIOR CANTED FRAME STA 1303 BETWEEN L14R AND 15R SKIN CRACKED AT FASTENER. REMOVED EXISTING DOUBLER IAW SRM 51-30-08. FABRICATED NEW DOUBLER IAW 53-01 FIG 2, SHT 3 AND 51-10-2. STOP DRILLED CRACK IAW 53-01, FIG 2, SHT 3. NDT VERIFIED CRACK CONTSDR DALA1100709864Wedge · crackedLT WING FLAP T/E WEDGE CRACKED ON INBD RIB CAP AT T/E. CUTOUT DAMAGED AREA IAW SRM 51-70-05. FABRICATED 2EA REPAIR ANGLES. FABRICATED FILLER IAW SRM 51-70-05. LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW 51-10-3. INSTALLED ANGLES AND FILLERSDR DALA1100719864Hinge Bracket · crackedLT WING T/E FLAP NR4 HINGE BRACKET CRACKED AT MOUNT HOLE FLAP SIDE. REMOVED L/E PANEL, T/E FLAP LT WING FLAP T/E PANEL 1548A, OTBD HINGE BRACKET, NR 4 FLAP HINGE FITTING AND 2 EA ANGLES IAW SRM 51-30-1,51-30-2. RECEIVED OTBD HINGE BRACKET LOCATED, DRILLED SDR DALA1036839855Frame · crackedDURING M-CHECK, FOUND FWD CARGO BS 560, LT STRUT CRACKED AT LOWER END. REMOVED FASTENERS IAW SRM 51-30-2,FABRICATED REPAIR DOUBLER AND TRIPLER IAW 53-01, FIG 2. TREATED AND PRIMED DOUBLER AND TRIPLER IAW SRM 51-10-3. STOP DRILLED CRACK IAW 53-01, FIG 2. INSSDR DALA1036849855Skin · corrodedDURING M-CHECK FOUND EXISTING CONDITION OF AFT CARGO SKIN AS PER AA 5331-01170-06, STEP 2, SCAN ALSO SHOWS WIDESPREAD CORROSION AT L30. R & R AFT CARGO BELLY SKIN IAW CARD 5331-01182D.SDR DALA1036859855Longeron · corrodedDURING M-CHECK, FOUND FWD CARGO BETWEEN BS 484 AND BS 503 L30 HAS CORROSION. REMOVED SECTION OF LONGERON FS 414-551, LONGERON SPLICE FABRICATED ON TRAVELER 2312N09800. INSTALLED LONGERON AND SPLICE IAW SRM 53-01, FIG 1,51-30-2,51-30-5,53-02 FIG 14,51-10-3.SDR DALA1036869864Floor Panel · damagedDURING M-CHECK, FOUND HOLE IN MAIN CABIN FLOOR PANEL 32. CUTOUT DAMAGE IAW 53-01, FIG 4. NDT VERIFIED DAMAGE WAS CONTAINED IAW NDT SPM 06-10-01.001. FABRICATED DOUBLER AND FILLER IAW SRM 53-01, FIG 4. TREATED AND PRIMED DOUBLER AND FILLER IAW SRM 51-10-3. SDR DALA1036879864Floor Panel · crackedDURING M”-CHECK, FOUND MAIN CABIN FLOOR PANEL NR74 HAS CRACK ON END. CUTOUT DAMAGED AREA IAW SRM 51-70-4. FABRICATED AND INSTALLED FILLER FABRICATED DOUBLER IAW SRM 51-70-4. INSTALLED FILLER AND DOUBLER IAW SRM 51-30-2, 51-70-4.SDR DALA1036889864Floor Panel · corrodedDURING M-CHECK, FOUND MAIN PASSENGER CABIN FLOOR PANEL NR20 CORRODED OUT OF LIMITS. LOCATED AND DRILLED NEW FLOOR PANEL. INSTALLED NUTPLATES. R & R G-1 GALLEY DRAIN PAN IAW SRM 51-10-4,51-30-2.SDR DALA1036899864Bracket · chafedDURING M-CHECK, FOUND LOWER FUSELAGE FWD CARGO COMPARTMENT OVERHEAD BS 389, BRACKET CHAFED. FABRICATED, LOCATED, DRILLED THE HOLES, ALODINED AND PRIMED R & R IAW 53-05, FIG 86, 51-30-5 51-10-3, 51-10-4.SDR DALA1036909864Floor Support · corrodedREMOVED FLOOR SUPPORT IAW SRM 51-30-02. REMOVED CORROSION IAW SRM 53-13-1, FIG 11 OUT OF LIMITS IAW SRM 53-01, FIG 1. FABRICATED AND INSTALLED FLOOR SUPPORT IAW SRM 51-10-4 AND 51-30-05.SDR DALA1036919864Floor Support · corrodedDURING M-CHECK, FOUND MAIN PASSENGER CABIN BETWEEN STA 200-218, RBL 18 FLOOR PANEL SUPPORT HAS CORROSION. REMOVED FLOOR PANEL SUPPORT IAW SRM 51-30-0. REMOVED CORROSION IAW SRM 51-10-3. OUT OF LIMITS IAW SRM 53-01, FIG 1. RECEIVED IEA RAW MATERIAL IAW SRM SDR DALA1036929864Channel · crackedDURING M-CHECK, FOUND NLG STA 37, RBL-6 CHANNEL CRACKED IN 2 PLACES. REMOVED CHANNEL NLG STA 37, RBL 6 IAW SRM 51-30-5. FABRICATED LOCATED, DRILLED NEW CHANNEL IAW SRM 51-10-2, 51-10-4. ALODINED AND PRIMED NEW CHANNEL IAW SRM 51-10-3. INSTALLED NEW CHANNEL SDR DALA1036939864Floor Panel · corrodedDURING M-CHECK, FOUND MAIN CABIN FLOOR PANEL 78 HAS CORROSION AROUND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-10-3, MAT LOSS FOUND TO BE OUT OF LIMITS. FABRICATED DOUBLER IAW SRM 51-70-4, 2 EA HOLES. REMOVED CORROSION ON 8 OF 10 HOLES FOUND TO BE WITHIN SDR DALA1036739855Cusp Web · chafedDURING M-CHECK, FOUND BS 693, RT MAIN FRAME JUST BELOW FLOOR CUSP WEB REPAIR IS CHAFING FRAME. BLENDED CHAFE ON FRAME BY HAND NO MATERIAL LOSS. TREATED AND PRIMED IAW SRM 51-10-3. FOUND AJACENT REPAIR CRACKED. REMOVED IAW SRM 51-30-2. NDT VERIFIED NO CRACKSDR DALA1036749855Cusp Web · crackedDURING M-CHECK FOUND BS 693-712 CUSP WEB IS CRACKED AS VIEWED FROM FWD CARGO KIDNEY AREA, RT SIDE. REMOVED TOP GUSSET AROUND FRAME 693 FOR ACCESS IAW SRM 51-30-2. CUTOUT DAMAGED AREA OF CUSP IAW A53-10-16-801-663A-A. NDT VERIFIED NO CRACKS IAW NDT SPM 06-10SDR DALA1036759855Floorbeam · crackedDURING M-CHECK, FOUND MAIN CABIN FLOOR SUPPORT WEB AT BS 753 RBL 40 IS CRACKED AT UPPER RIVET. HFEC INSP IAW NDT SPM 06-10-01.001 VERIFIED CRACK CONTAINED BY FASTENER HOLE. FABRICATED REPAIR DOUBLER IAW SRM 53-01, FIG 2 AND SRM 53-13-3, FIG 1. INSTALLED DOUBSDR DALA1036799855Longeron · corrodedDURING M-CHECK, FOUND AFT CARGO STA 1114, L26R LONGERON END CAP EXFOLIATED. FOUND ON OPEN UP FOR 52-04, FIG 12C REPAIR. R & R END CAP IAW SRM 51-30-2, 51-30-5.SDR DALA1036829864Intercostal · misinstalledDURING M-CHECK, FOUND AFT CARGO HAS DOUBLE DRILLED HOLE IN INTERCOSTAL AT BS 1116 L28R. R & R INTERCOSTAL IAW SRM 51-30-5,53-13-3, FIG 3.SDR DALA1036499864Skin · tornDURING M-CHECK, FOUND VERTICAL STABILIZER RUDDER TOP END, RT SIDE SKIN TORN AT EDGE. REMOVED DAMAGED AREA ON VERTICAL STAB RUDDER IAW SRM 51-70-06, FIG 2, SHT 1. HFEC INSP NO OTHER DAMAGE NOTED NDT SPM 06-10-01.001. FABRICATED AND DRILLED DOUBLER AND FILLERSDR DALA1036509864Intercostal · crackedDURING M-CHECK, FOUND AFT ACC COMPARTMENT STA 1339, LT LOWER INTERCOSTAL AT TAILCONE CABLES CRACKED AND BENT. REMOVED CRACKED INTERCOSTAL IAW SRM 51-30-5. FABRICATED NEW INTERCOSTAL IAW DWG NR 9917701-3. TREATED AND PRIMED IAW SRM 51-30-5 & 51-30-2.SDR DALA1036519864Pan · corrodedDURING M-CHECK, FOUND AFT CARGO COMPT DOOR CUT OUT LOWER PAN CORRODED. REMOVED CORROSION IAW SRM 51-10-3. MATERIAL LOSS OUT OF LIMITS IAW SRM 53-01, FIG 1. R & R DOOR JAMB PAN IAW SRM 51-30-2, 51-30-5, 51-30-4, 53-05 FIG 44. REINSTALLED ALL PARTS IAW SRM 51-SDR DALA1036539864Floor Support · corrodedDURING M-CHECK FOUND LAVATORY, STA 1139, RBL 22 FLOOR PANEL SUPPORT HAS CORROSION. REMOVED FLOOR PANEL SUPPORT IN LAV AREA STA 1139, RBL 22 IAW SRM 51-30-2. FABRICATED NEW FLOOR PANEL SUPPORT IAW DWG 94FS481223 TREATED, PRIMED AND TOPCOATED IAW SRM 51-10-3, SDR DALA1036559864Floor Panel · corrodedDURING M-CHECK, FOUND MAIN CABIN FLOOR PANEL 103 AROUND FASTENER HOLES CORRODED. RECEIVED NEW MAIN CABIN FLOOR PANEL, TO BE INSTALLED ON JOB CARD 0590-4020-8M. LOCATED IAW SRM 51-10-4A.SDR DALA1036569864Floor Panel · corrodedDURING M-CHECK, FOUND AFT LT PANEL NR 73, CORROSION AROUND FASTENER HOLES. RECEIVED NEW MAIN CABIN FLOOR PANEL 73 TO BE INSTALLED ON JOB CARD 0590-4020-8M. LOCATED IAW SRM 51-10-4.SDR DALA1036579864Floorboard · chafedDURING M-CHECK, FOUND CABIN FLOORBOARD 89 CHAFING MARKS FROM FASTNERS AT EXISTING HOLES. REMOVED DAMAGED AREA HFEC NDT SPM 06-10-01.001. REPAIRED PANEL IAW SRM 51-70-4. INSTALLED IAW SRM 51-30-2 AND SRM 51-70-4, FIG 1.SDR DALA1036589864Cusp Web · crackedDURING M-CHECK, FOUND MAIN PAX CABIN RT SIDE CUSP WEB HAS 1EA CRACK AND SEVERAL ELONGATED HOLES UNDERNEATH OF OTBD SEAT TRACK AT STA 258, RBL 46. CUTOUT DAMAGED SECTION OF CUSP WEB IAW SRM 51-10-4 & SRM 53-10-16-801-663A-A. LOCATED DRILLED DEBURRED & PRIMED TSDR DALA1036599864Cusp Web · dentedDURING M-CHECK, FOUND MAIN PAX CABIN RT SIDE CUSP WEB HAS 1EA DENT AT LIGHTNING HOLE AND SEVERAL ELONGATED HOLES UNDERNEATH OF OTBD SEAT TRACK FROM BS 237 TO BS 254 RBL 46. CUTOUT DAMAGED SECTION OF CUSP WEB IAW SRM 51-10-4 & SRP DC9-A-53-10-16-801-663A-A. LSDR DALA1036609864Floor Panel · gougedDURING M-CHECK, FOUND MAIN CABIN FLOOR PANEL NR32 GOUGED 2 PLACES IN FLOOR PANEL. BLENDED GOUGES IAW SRM 53-01, FIG 1. MATERIAL FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 CUTOUT DAMAGED SECTION OF CHANNEL IAW SRM 53-05, FIG 1. FABBED 2EA CHANNELS IAW SRMSDR DALA1036619864Floor Support · corrodedDURING M-CHECK, FOUND MAIN PASSENGER CABIN STA 310-313, BL 0, FLOOR PANEL SUPPORT HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3 LOSS OUT OF LIMITS IAW SRM 53-01 FIG 1, CUTOUT SECTION BS 310-348, BL 0 FLOOR SUPPORT REPAIR ANGLES TAPERED 4EA ANGLES ON TRAVELSDR DALA1036339855Gusset · corrodedDURING M-CHECK, FOUND FWD CARGO LT FWD GUSSET AT DOOR JAMB WEB HAS CORROSION. FABRICATED NEW GUSSET LOCATED, DRILLED, DEBURRED, TREATED AND PRIMED GUSSET IAW SRM 53-13-2, 51-10-2, 51-10-3, 51-10-4. GUSSET WAS TAPERED IAW DWG 5910142 ON NR 2312N02007.SDR DALA1036419855Floor Panel · damagedDURING M-CHECK FOUND FLOOR PANEL 26, 2 FASTENER HOLES ARE ELONGATED. REPAIRED PANEL IAW SRM 53-05, FIG 1. CUTOUT DAMAGE 4.5"X2". HFEC NDT SRM 06-10-01, NO CRACK FOUND.SDR DALA1036439855Floor Panel · corrodedDURING M-CHECK, FOUND FLOOR PANEL 26, CORROSION AT CORNER BOTTOM SECTION. CORRODED OUT OF LIMITS IAW SRM 53-01, FIG 1. REPAIRED IAW 51-70-4, FIG 1. R & R DOUBLER IAW SRM 51-30-2 AND 51-70-4.SDR DALA1036369864Cusp Web · crackedDURING M-CHECK, FOUND MAIN PAX CABIN RT SIDE CUSP WEB HAS 1EA CRACK UNDERNEATH OF OTBD SEAT TRACK AT FS280, RBL 46. CUTOUT DAMAGED SECTION OF CUSP WEB, FS 280 RBL 46 IAW SRM 51-10-4 AND SRP DC-9-A-53-10-16-801-663A-A. FABRICATED REPAIR DOUBLER AND INSTALLED ISDR DALA1036379864Cusp Web · crackedDURING M-CHECK, FOUND MAIN CABIN RT CUSP WEB IS CRACKED OVER FLOOR SUPPORT STA 579, ABOVE OTBD RIVET EXTENDING 1" FWD AND .2500" AFT OF SUPPORT. REMOVED FLOOR PANEL IAW SRM 51-30-1. REMOVED FLOOR SUPPORT IAW SRM 51-30-2. CUT OUT CRACKED SECTION OF WEB IAW SSDR DALA1036389864Bulkhead · crackedDURING M-CHECK, FOUND NOSE WHEEL WELL THROUGH ACCESS HOLE STA 69, LBL 12 BULKHEAD WEB IS CRACKED APPROX .5". STOP DRILLED CRACK IAW SRM 53-01, FIG 2. HFEC INSP IAW NDT SPM 06-10-01 VERIFIED CRACK CONTAINED. FABRICATED AND INSTALLED DOUBLER IAW SRM 53-01, FSDR DALA1036399864Intercostal · corrodedDURING M-CHECK FOUND AFT CARGO STA 1116 BETWEEN L27R AND L28R INTERCOSTAL HAS CORROSION. REMOVED CORROSION ON INTERCOSTAL OUT OF LIMITS. REMOVED INTERCOSTAL, INSTALLED GUSSET AND STRAP IAW SRM 53-01, FIG 1,51-30-2 51-30-5.SDR DALA1036409864Gusset · corrodedDURING M-CHECK, FOUND AFT CARGO STA 1108 GUSSET HAS CORROSION FRONT AND BACK SIDE. LOWER AFT CARGO JAMB CORNER. REMOVED CORROSION IAW SRM 51-10-3 FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1. R & R GUSSET IAW SRM 51-30-2, 51-30-5.SDR DALA1036479855Floor Support · crackedDURING M-CHECK, FOUND MAIN PASSENGER CABIN FLOORBOARD NR89 HAT CHANNEL IS CRACKED. REMOVED DAMAGED HAT CHANNEL 2EA HFEC NDT SPM 06-10-01. REPAIRED HAT CHANNEL IAW SRM DC-9 53-05 FIG 1 PG10. INSTALLED HAT CHANNEL IAW DC-9 51-30-2 AND 53-05 FIG 1, PG 10.SDR DALA1036529864Pan · corrodedDURING M-CHECK, FOUND AFT CARGO STA 1068 TO 1106 LOWER PAN AT DOOR CUTOUT HAS CORROSION SEVERAL PLACES. REMOVED CORROSION IAW SRM 51-10-3. MATERIAL LOSS OUT OF LIMITS IAW SRM 53-01, FIG 1. R & R WEB IAW SRM 51-30-2, 51-30-5, 51-30-4, 53-13-3.SDR DALA1036119855Attach Bracket · crackedDURING M-CHECK, FOUND FWD CARGO COMPARTMENT DOOR CUTOUT STA 408 FLOORBEAM RBL56, ATTACH BRACKET CRACKED. LOCATED, DRILLED AND INSTALLED NEW BRACKET IAW SRM 51-30-2,51-30-5,51-10-4.SDR DALA1036129855Doubler · corrodedDURING M-CHECK FOUND FWD CARGO-FS 325-330 ANTENNA DOUBLER HAS ELONGATED HOLES AND CORROSION. FABRICATED NEW DOUBLER IAW SRM 51-10-4, 51-10-2 AND MATERIAL ID IAW SRM 53-33-0, ITEM 7 TREATED PRIMED AND TOPCOATED IAW SRM 51-10-3.SDR DALA1036179855Stop Fitting · crackedDURING M-CHECK FOUND MAIN CABIN AFT ENTRY DOOR JAMB LT UPPER STOP FITTING CRACKED AT FASTENERS. REMOVED 2EA STRAPS, 1EA STOP FITTING PLATE AND 1EA STOP FITTING. INSTALLED 1EA STOP FITTING, 1EA STOP FITTING PLATE AND 2EA STRAPS IAW SRM 51-30-2, 51-30-5.SDR DALA1036189855Frame · damagedDURING M-CHECK, FOUND AFT CARGO COMPARTMENT STA 1136 AT L24L FRAME HAS DAMAGE ON TOP SIDE. FABRICATED AND INSTALLED REPAIR STRAP ON AFT CARGO COMPARTMENT FRAME AT STA 1136 IAW NWA SRP DC-9 A-53-10-05-801-663A-A.SDR DALA1036209864Support Angle · crackedDURING M-CHECK FOUND MAIN PASSENGER CABIN STA 160-200 LBL 55 Z ANGLE SUPPORT IS CRACKED. REMOVED Z-ANGLE FABRICATED AND INSTALLED NEW ANGLE IAW SRM 51-30-1.SDR DALA1036229864Bulkhead · crackedDURING M-CHECK, FOUND NOSE WHEEL WELL LT TUNNEL STA 105, LBL 35 PRESSURE DECK WEB IS CRACKED. FABRICATED AND INSTALLED FILLER AND DOUBLER IAW SRM 51-30-05, 51-20-0 AND DELTA DC-9-A-53-10-02-801-663A-A.SDR DALA1036239864Fitting · brokenDURING M-CHECK, FOUND RT WING OTBD FLIGHT SPOILER TORSION BAR INBD FITTING IS BROKEN AT WING AFT SPAR. R & R OTBD SPOILER INBD FITTING IAW SRM 51-30-2 51-30-5.SDR DALA1035929864Floor Panel · damagedDURING M-CHECK, FOUND MAIN CABIN FLOOR PANEL 77, SKIN AND RIB CRACKED. CUTOUT DAMAGED SECTION OF HAT CHANNEL IAW SRM 53-05, FIG 1 FABRICATED DOUBLER AND 2EA HAT CHANNELS, TREATED AND PRIMED IAW SRM 51-10-3.SDR DALA1035939864Floor Support · mismanufacturedDURING M-CHECK FOUND MAIN PASSENGER CABIN STA 160, LBL 55 FLOOR PANEL SUPPORT HAS A DOUBLE DRILLED HOLE. REMOVED CLOSEOUT PANEL AND FLOOR SUPPORT IAW SRM 51-30-02 AND 51-30-05. FABRICATED NEW SUPPORT IAW SRM 51-10-2 AND 51-10-4. INSTALLED NEW FLOOR SUPPORT A
Back to Pratt & Whitney JT8D-9