JASC 5321

Service difficulty reports · 49,402

Reports filed under 5321 · Fuselage Floor Panel, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '5321'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR F3LA200800111Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED DELAMINATION WAS FOUND ON THE TOP SURFACE OF FLOOR PANEL 252NF. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 212. FOLLOWING COMPLETION OF THE REPAIR, THE FLOORMar 2, 2008 · N813FR · Airbus A319111SDR F3LA200800110Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED DELAMINATION WAS FOUND ON FLOOR PANEL 251NF. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 212. FOLLOWING COMPLETION OF THE REPAIR, THE FLOOR PANEL WAS INSPECTEMar 2, 2008 · N913FR · Airbus A319112SDR F3LA200800109Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED DELAMINATION WAS FOUND ON THE UPPER SURFACE OF FLOOR PANEL 252GG. MAINTENANCE REPAIRED THE PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 212. FOLLOWING COMPLETION OF THE REPAIR, THE PANEL WASMar 2, 2008 · N913FR · Airbus A319112SDR F3LA200800107Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED POTTED INSERTS WERE FOUND MISSING ON THE AFT GALLEY 261PF FLOOR PANEL. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-12 PB 401. FOLLOWING THE INSTALLATION OF THE NEMar 2, 2008 · N913FR · Airbus A319112SDR F3LA200800093Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED FLOOR PANEL 231MF WAS PUNCTURED ON ITS TOP SURFACE. MAINTENANCE REPAIRED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF A319 SRM 53-02-00, FIGURE 201, ZONE A. UPON COMPLETION OF THE REPAIR, THE FLOOR PANEL WAMar 2, 2008 · N913FR · Airbus A319112SDR F3LA200800085Floor Panel · damagedDURING C4/S1 C CHECK, INSPECTION REPORTED SEVERAL POTTED INSERTS WERE MISSING FROM AFT GALLEY FLOOR PANEL 261PF. MAINTENANCE REMOVED AND REPLACED THE DAMAGED PANEL IN ACCORDANCE WITH AMM 53-42-12 PB 401. FOLLOWING THE REPLACEMENT OF THE DAMAGED PANEL, THE NEMar 2, 2008 · N913FR · Airbus A319112SDR AMTA200800186Floor Panel · corrodedPANEL 140CF FOUND WITH LIGHT CORROSION. REMOVED CORROSION IAW SRM 51-10-02, ORG MAT .071, MAT LOSS .003, REM MAT .068, FOUND TO BE WITHIN LIMITS IAW SRM 53-00-53, ALODINED AND PRIMED IAW SRM 51-20-01. (K)Feb 28, 2008 · N314TZ · Boeing 73783NSDR AMTA200800185Floor Panel · corroded120AF FLOOR PANEL HAS CORROSION AROUND EDGES. REMOVED CORROSION, ORG MAT .080, MAT LOSS .001, REM MAT .079, FOUND TO BE WITHIN LIMITS 53-0053-1A, ALODINED AND PRIMED IAW SRM 51-20-01-0G. (K)Feb 28, 2008 · N314TZ · Boeing 73783NSDR F3LA200800084Cover · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED CORROSION WAS FOUND ON THE COVER SHEET OF AFT CARGO PIT FLOOR PANEL 151VG. MAINTENANCE REMOVED THE CORRODED COVER SHEET FROM THE FLOOR PANEL. A REPLACEMENT COVER SHEET WAS FABRICATED IN ACCORDANCE WITH THE REQUIREMENFeb 28, 2008 · N913FR · Airbus A319112SDR F3LA200800076Floor Panel · corrodedDURING C4/S1 C CHECK, INSPECTION REPORTED DAMAGE AND CORROSION WAS FOUND ON AFT CARGO PIT, REINFORCED FLOOR PANEL 151ZG. MAINTENANCE REPAIRED THE FLOOR PANEL BY FABRICATING A NEW COVER SHEET FROM 2024-T3 AL IN ACCORDANCE WITH THE REQUIREMENTS OF E0 53-42-319-Feb 28, 2008 · N913FR · Airbus A319112SDR 08FDEA00650Floor Panel · tornCENTER PIT PANEL "183 BG" IS PUNCTURED. FABBED NEW FLOOR PANEL 183 BG IAW DWG SRZ 25-005 REV E. MAJOR REPAIR.Feb 28, 2008 · N315FE · Doug DC1030SDR TRAX200800332Floor Panel · brokenAFT LAND OF CENTER COCKPIT FLOOR BADLY CORRODED. REMOVED AND REPLACED AFT FLOOR LAND OF CENTER COCKPIT PER SRM 51-42-21.Feb 26, 2008 · N354CA · Cndair CL6002C10SDR USAA920080604Floorboard · corrodedSAL - MAJOR REPAIR - C7 CHECK - CORROSION ON CABIN FLOORBOARD 262FF. REPLACED CABIN FLOORBOARD 262 FF IAW A319 AMM 53-42-12.Feb 25, 2008 · N801AW · Airbus A319132SDR F3LA200800074Floor Panel · damagedDURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151ZG WAS DAMAGED BEYOND REPAIRABLE LIMITS. MAINTENANCE REMOVED AND REPLACED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14-400-001. FOLLOWING THE REPLACEMENT OF THE FLOOR Feb 23, 2008 · N949FR · Airbus A319111SDR F3LA200800075Floor Panel · damagedDURING C1 C CHECK, INSPECTION REPORTED AFT CARGO PIT FLOOR PANEL 151VG WAS DAMAGED BEYOND REPARABLE LIMITS. MAINTENANCE REMOVED THE FLOOR PANEL IN ACCORDANCE WITH THE REQUIREMENTS OF AMM 53-42-14-000-001 AND REPLACED IT WITH A NEW FLOOR PANEL IN ACCORDANCE WIFeb 23, 2008 · N949FR · Airbus A319111SDR 2008UALA00992Floorboard · damagedCARGO FLBRD RPL S GLS PNL. MAJOR REPAIR ACCOMPLISHED AT LCQ VIA COA PROJECT.Feb 22, 2008 · N438UA · Airbus A320232SDR UPS08851747Floorboard · elongatedINSPECTION TYPE:C2 RT STA 785-1000 FLOORBOARD F94A/F94B HAS SEVERAL ELONGATED FASTENER HOLES. REPAIRED RT F94A/F94B FLOORBOARD FASTENER HOLES IAW DWG 5758265 AND SRM 53-02-03-0 FIG 010.Feb 21, 2008 · N852UP · Doug DC873FSDR 2008UALA00989Floorboard · damagedCARGO FLOORBOARD RPL S GLS PNL. ACCOMPLISHED FLOORBOARD REPLACEMENT. **MAJOR REPAIR**.Feb 21, 2008 · N488UA · Airbus A320232SDR 2008UALA00988Floorboard · damagedCARGO FLOORBOARD RPL S GLS PNL. MAJOR REPAIR ACCOMPLISHED AT LCQ (COA ACCOMPLISHED).Feb 21, 2008 · N801UA · Airbus A319131SDR 08FDEA00555Floor Panel · delaminatedMAIN CABIN FLOORBOARD AT APPROX LBL-60, BETWEEN STA 1239 TO 1321 IS DELAMINATED. MAT ID A402H35039-003 PO 590899.1. FABRICATED NEW BOARD, MAT ID POTTING COMPOUND 1619 A/B PO 666417.3. INSERT SLS 5094A3-400-2 PO 595255, INSERT SLP 5094A3-2 PO 595242. ADHEFeb 21, 2008 · N315FE · Doug DC1030FSDR 08FDEA00554Floor Panel · delaminatedMAIN CABIN FLOOR PNL FROM STA 1341, LBL-20 FWD EDGE IS DELAMINATED. MAT ID A402H PO590899.1 IAW FEDEX DWG SRZ 25-005 REV F. FABBED FLOOR PNL IAW FEDEX DWG SRZ 25-005 REV F. MAT ID POTING COMP 1619 A/B PO 606417.3. INSERT SLS 5094A3-400-2 PO 595225, INSERFeb 21, 2008 · N315FE · Doug DC1030FSDR 08FDEA00553Floor Panel · delaminatedMAIN CABIN FLOORBOARD AT APPROX LBL-90, BETWEEN STA 1481 TO 1561 IS DELAMINATED. MAT ID A402H35039-003 PO 5990899.1. POTTING COMPOUND 1619 A/B PO 606417.3, INSERT SLS 5094A3-400-2 PO 595225, INSERT SLP 5094A3-2 PO 595242. ADHESIVE EPIBOND 420 A/B PO 594846.Feb 21, 2008 · N315FE · Doug DC1030FSDR 08FDEA00552Floor Panel · delaminatedMAIN CABIN CABIN FLOORBOARD AT APPROX LBL-20, BETWEEN STA 495 TO 615 IS DELAMINATED. MAT ID A420H PO 590899.1 IAW FEDEX DWG SRZ 25-005 REV F. FABBED FLOORBOARD PNL IAW FEDEX DWG SRZ 25-005 REV F. MAT ID POTTING COMP 1619 A/B PO 6064173. INSERT SLS 5094A3Feb 21, 2008 · N315FE · Doug DC1030FSDR UPS08851765Floorboard · crackedINSPECTION TYPE:C2 FLT DECK PANEL 682A HAS DOUBLE DRILLED HOLES WITH NO ED AND ALL HAT CHANNELS CHAFED. FABRICATED AND INSTALLED 1 WEB AND 6 HAT CHANNELS IAW DWG 56935 7 AND S275589.Feb 20, 2008 · N852UP · Doug DC873FSDR UPS08851758Floor Panel · corrodedINSPECTION TYPE:C2 FLT, DECK FLOOR PNL 678 HAS MANY BADLY BUCKED RIVETS WITH SOME HAT CHANNEL RADIUS, ALSO CORROSION AROUND FASTENER HOLES. FABRICATED FLT DECK FLOOR PANEL NR 678 IAW SRM 57-07-00 FIG 049B.Feb 20, 2008 · N852UP · Doug DC873FSDR CA080219006Floor Panel · corroded(CAN) AFT CARGO PIT FLOOR CHANNEL CORRODED AT BS 767+6, LBL 3 AND REPAIRED IAW CUSTOMER EA. (TC NR 20080219006)Feb 19, 2008 · Boeing 7374S3SDR UPS08851751Floorboard · damagedINSPECTION TYPE:C2 COCKPIT FLOORPANEL 680 HAS LARGE FIELD REPAIR, DAMAGE CHANNELS AND SKIN. FABRICATED COCKPIT FLOORPANEL 680 IAW DWG 3619352 AND S2755898, SRM 51 -1-8 AND SRM 51-01-21.Feb 19, 2008 · N852UP · Doug DC873FSDR UPS08851737Panel · corrodedINSPECTION TYPE:C2 COCKPIT FLOOR PNL 676E HAS CORROSSION. REPAIRED COCKPIT FLOOR PNL, BY FABRICATION IAW SRM 53-07-03 FIG 001.Feb 19, 2008 · N852UP · Doug DC873FSDR USAA920080510Floorboard · crackedSAL - MAJOR REPAIR - C7 CHECK - CORROSION ON CABIN FLOORBOARD 262FF, BS 3158/FR 66 - BS 3257/FR 68, -Y1292 TO -Y1732. REPLACED CABIN FLOORBOARD 262FF, BS 3158/FR 66 - BS 3257/FR 68, -Y1292 TO -Y1732 IAW A320 SRM 51-72-11.Feb 19, 2008 · N653AW · Airbus A320232SDR UPS08551727Floor Panel · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOOR PANEL DENTED BS 1488 RBL 55 WL 208. REMOVED DAMAGED FLOOR PANEL, FABRICATED REPLACEMENT PANEL. INSTALLED REPLACEMENT PANEL PER B757-5320-9692-F M/M 25-55-04-4.Feb 18, 2008 · N456UP · Boeing 75724APFSDR UPS08551726Floor Panel · dentedINSPECTION TYPE:C2 MAIN CARGO COMPARTMENT FLOOR PANEL DENTED AT BS 1488 RBL 42 WL 208. REMOVED DAMAGED FLOOR PANEL, FABRICATED REPLACEMENT PANEL. INSTALLED REPLACEMENT PANEL PER B757-5320-9692F M/M 25-55-04-4.Feb 18, 2008 · N456UP · Boeing 75724APFSDR 08FDEA00505Floorboard · crackedMAIN CABIN FLOOR PANEL NR 242EK IS CRACKED. FABRICATED NEW FLOOR PNL NR 242EK IAW FEDEX DWG SRZ 25-005 REV F FOR INSTALLATION, SEE W/C 62C0702. MAJOR REPAIR.Feb 18, 2008 · N684FE · Airbus A300F4605RSDR 08FDEA00504Floorboard · crackedMAIN CABIN FLOOR PANEL NR 242 RG IS CRACKED. FABRICATED NEW FLOORBOARD PNL NR 242RG IAW FEDEX DWG SRZ 25-005 REV F FOR INSTALLATION SEE W/C 62C0702.Feb 18, 2008 · N684FE · Airbus A300F4605RSDR 08FDEA00503Floorboard · crackedMAIN CABIN FLOOR PANEL 242 ZJ IS CRACKED. FABRICATED NEW FLOOR BOARD PNL NR 242ZJ IAW FEDEX DWG SRZ 25-005 REV F FOR INSTALLATION SEE W/C 62C0702.Feb 18, 2008 · N684FE · Airbus A300F4605RSDR 08FDEA00506Floorboard · damagedMAIN CABIN FLOOR PNL 232 YG IS CRUSHED. FABRICATED NEW FLOOR BOARD PNL NR 232 YG IAW FEDEX DWG SRZ 25-005 REV F. FOR INSTALLATION SEE W/C 62C0701.Feb 18, 2008 · N684FE · Airbus A300F4605RSDR 08FDEA00502Floorboard · crackedMAIN CABIN FLOOR BOARD 242UJ IS CRACKED. FABRICATED NEW FLOOR BOARD PNL NR 242UJ IAW FEDEX DWG SRZ 25-005 REV F. FOR INSTALLATION SEE W/C 62C0702.Feb 18, 2008 · N684FE · Airbus A300F4605RSDR 08FDEA00500Floorboard · delaminatedCABIN FLOORBOARD BS 675 LBL 27.50 DELAMINATED AND CRACKED. FABBED FLOORBOARD IAW DWG SRZ 25-005 REV F. LOCATED AND POTTED INSERTS IAW DWG SRZ 25-005 REV F. INSTALLED NON-SKID, POTTED AND SANDED EDGES IAW DWG SRZ 25-005 REV F. INSTALLED NEW FLOORBOARD IAW SFeb 18, 2008 · N315FE · Doug DC1030SDR 08FDEA00499Floorboard · delaminatedMAIN CABIN FLOORBOARD AT APPROX BL-0 BETWEEN STA 495 TO 615 IN DELAMINATED. FABRICATED NEW FLOOR BOARD PANEL STA 495 TO 615, POTTED EDGES, COMPLETED CURE AND SANDED EDGE POTTING. INSTALLED INSERTS, APPLIED NON-SKID AND PART MARKED IAW SRZ 25-005 REV F. INSTFeb 18, 2008 · N315FE · Doug DC1030FSDR 08FDEA00498Floorboard · delaminatedMAIN CABIN FLOORBOARD AT APPROX LBL - 90, BETWEEN STA 595 TO 675 IS DELAMINATED. FABRICATED NEW FLOORBOARD STA NR 595 - 675. POTTED EDGES, COMPLETED CURE AND SANDED, INSTALLED INSERTS, APPLIED NON-SKID MARKED MANUAL IAW SRZ 25-005 REV F. INSTALLED IAW SRM 5Feb 18, 2008 · N315FE · Doug DC1030FSDR USAA920080455Floorboard · corrodedSAL - MAJOR REPAIR - C7 CHECK - CORROSION ON CABIN FLOORBOARD 261FF, BS 3158 / FR 66 - BS 3257 / FR 68, +Y1292. REPLACED CABIN FLOORBOARD 261FF, BS 3158 / FR 66 - BS 3257 / FR 68, +Y1292 IAW A320 SRM 51-72-11.Feb 17, 2008 · N653AW · Airbus A320232SDR 2008UALA00871Pressure Panel · crackedPRESSURE DECK AT BS 664 IS CRACKED ON FWD EDGE OF CORRIGATION LBL32. INSTALLED EXTERNAL DOUBLER & FILLER REPAIR COMMON TO PRESSURE DECK IAW MM 53-21-98. AC OK FOR SERVICE.Feb 17, 2008 · N376UA · Boeing 737322SDR 08FDEA00459Floorboard · damagedMAIN CABIN FLOORBOARD AT APPROX RBL-20, BETWEEN STA 1821 TO 1761 IS SPONGY. FABBED FLOORBOARD, LOCATED AND POTTED INSERTS, POTTED AND SANDED THE EDGES AND APPLIED THE ANTI-SKID IAW DWG SRZ-005 REV F. INSTALLED FLOORBOARD IAW SRM 51-31-01 VOL II.Feb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00458Floor Panel · delaminatedUPPER CARGO COMPARTMENT, AFT SECTION, LT SIDE AT STA 1741, THE O/B PANEL NR 281 FE (ORANGE) (MARKED AS "14L") IS DELAMINATED AND HAS TWO SMALL PUNCTURES. FABRICATED NEW FLOOR PANEL 281FE, POTTED EDGE, COMPLETED CURE AND SANDED EDGE POTTING. INSTALLED INSERTSFeb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00457Floor Panel · delaminatedMAIN CABIN FLOOR PNL AT STA 1481 TO 1561, LBL 40 FWD CORNER DELAMINATED. FABRICATED NEW FLOOR PANEL STA 1481 TO 1561, POTTED EDGES, COMPLETED CURE AND SANDED EDGE POTTING. INSTALLED INSERTS, APPLIED NON-SKID AND PART MARKED IAW FEDEX SRZ 25-005 REV F.Feb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00456Floorboard · damagedMAIN CABIN FLOORBOARD AT LBL - 20, BETWEEN STA 1821 TO 1881 IS SPONGY. FABBED FLOORBOARD IAW SRZ-25-005 REF F. INSTALLED FLOORBOARD IAW SRM 51-31-01 VOL II. LOCATED, DIRLLED HOLES. INSTALLED INSERTS, INSTALLED ANTISKID IAW DWG SRZ 25-005 REV F. INSTALFeb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00455Floorboard · delaminatedMAIN CABIN FLOORBOARD AT APPROX RBL-90, BETWEEN STA 800 TO 850 IS DELAMINATED. REMOVED FLOORBOARD IAW AMM 53-21-01-2. FABBED FLOORBOARD IAW SRZ-25-005 REV F. LOCATED HOLES FOR INSERTS IAW DWG SRZ 25-005 REV F. POTTED EDGES AND STARTED CURE IAW DWG SRZ 25-0Feb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00454Floorboard · damagedMAIN CABIN FLOORBOARD AT APPROX LBL 38, BETWEEN STA 595 TO 675 IS WARPED. FABBED FLOORBOARD PANEL AT STA 595-675 IAW DWG SRZ 25-005 REV F. LOCATED HOLES, COUNTERBORED HOLES, POTTED INSERTS, POTTED EDGES, CURED EDGES, SANDED EDGES, APPLIED ANTI-SKID IAW Feb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00453Floor Panel · damagedCABIN FLOOR PANEL AT STA 555 RBL 8.5 TO 27.5 HAS EDGE DAMAGE AND HOLES. FABRICATED NEW FLOOR PANEL STA 555, POTTED EDGES, COMPETED CURE AND SANDED EDGE POTTING, INSTALLED INSERTS AND APPLIED ANTI-SKID IAW FEDEX DWG SRZ 25-005 REV F. THIS IS A MINOR RFeb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00452Floorboard · delaminatedMAIN CABIN FLOORBOARD AT APPROX RBL-20, AT APPROX BETWEEN STA 899 TO 979 IS DELAMINATED. FABBED NEW FLOORBOARD STA 899 TO 979, POTTED EDGES, COMPLETED CURE AND SANDED. INSTALLED INSERT , APPLIED ANTI-SKID, MARKED PNL IAW FEDEX DWG SRZ 25-005 REV F. THIS IFeb 15, 2008 · N315FE · Doug DC1030FSDR 08FDEA00441Floor Panel · tornMAIN DECK CARGO COMPARTMENT FLOORBOARD (SR30B5327071400200252) VF IS TORN. FABRICATED NEW FLOORBOARD PANEL NR 252 VF IAW SRZ 25-005 REV F.Feb 14, 2008 · N684FE · Airbus A300F4605R
Back to JASC 5321