JASC 5321
Service difficulty reports · 49,402
Reports filed under 5321 · Fuselage Floor Panel, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5321' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DHL9780147DFloor · corrodedAT C-CHECK, SUB FLOOR IS CORRODED AT FS 160 TO 200 BETWEEN NR 1 AND NR 2 SEAT TRACK. CUT OUT DAMAGED SECTION AND FABRICATED REPAIR DOUBLER AND INSTALLED PER SRM 53-2-0SDR SCNA97121Floor Panel · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON LAVATORY FLOOR STRUCTURE AT STATIONS 1130 TO 1165, LBL 18 TO 34. REMOVED, FABRICATED AND INSTALLED NEW PANEL IAW B727 SRM 51-40-02.SDR DHL9780134CFloor Panel · crackedAT C-CHECK, CRACK IN FLOOR PANEL IN MAIN ENTRY AREA AT FS 55.0 AT BL 121 HAS 3.5 CRACK. STOP DRILLED CRACK AND INSTALLED REPAIR PER SRM 53-2-0.SDR DHL9780132CFloor · corrosionAT C-CHECK, FOUND CORROSIOIN AT CABIN SUBFLOOR ATA 200 LEFT SIDE. CUT OUT DAMAGED SECTION OF SUBFLOOR MEMBRANE AND FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-2-0.SDR DHL9780131CFloor · corrodedAT C-CHECK, FWD CARGO COMPT CABIN FLOOR AT STA 240 LT SIDE COMPLETELY BROKEN OUT. CUT OUT DAMAGED SECTION OF FLOOR AND INSTALLED REPAIR DOUBLER PER SRM 53-2-0.SDR SCNA97122Floor Web · corrodedDURING HEAVY MAINTENANCE VISIT, CORROSION WAS FOUND ON FLOOR WEB NEAR AFT ENTRY STATION 1183, WL 208, LBL 20 TO RBL 20. REMOVED, FABRICATED, AND INSTALLED NEW WEB IAW B727 SRM 51-40-01.SDR CALA9700678Floor · corrodedINSPECTION FOUND AFT LAV FLOOR WEB CORRODED AT STA 994 TO 1016, LBL 37 TO LBL 46. THE CORRODED AREA WAS REMOVED, A REPAIR WAS FABRICATED AND INSTALLED IAW SRM 53-30-01 AND 51-30-2.SDR ABXA9700907Subfloor · crackedDURING C-CHECK, FOUND THE FORWARD SUBFLOOR MEMBRANE CRACKED AT FS 207 AND LBL 26. REPAIRED FORWARD SUBFLOOR MEMBRANE IAW DC9 SRM 53-01, FIGURE 1.SDR CALA9700690Floor · crackedINSPECTION FOUND A 1.5 INCH CRACK IN FLOOR WEB AT STA 986 TO 995, RBL 43. THE CRACKED AREA WAS REMOVED IAW SRM 51-40-2, A REPAIR DOUBLER WAS FABRICATED AND INSTALLED IAW SRM 51-40-3, 51-30-3, AND 51-10-3.SDR HALA9763Floor Panel · corrodedAFT CARGO PIT FLOOR PANEL STATION 1047 HAS LEVEL 2 CORROSION ON ATTACH DOUBLERS AND 'U' CHANNELS HAVE DOUBLER HOLES, WORN/PULLED FASTENERS. 'U' CHANNELS AND ATTACH DOUBLERS HAVE LEVEL 1 CORROSION ON SKIN. FABRICATED AND INSTALLED NEW SUPPORT RIBS. U-CHANNELSDR CALA9700419Floor Pan · corrodedINSPECTION FOUND LEFT AFT LAV FLOOR PAN CORRODED. A FILLER AND DOUBLER REPAIR WAS FABRICATED AND INSTALLED IAW SRM 51-40-2 AND 51-10-6.SDR HALA97104Floor Panel · crackedFLIGHT DECK FLOOR PANEL FS 110-160, LBL 15 TO RBL 15, HAS CORROSION LEVEL 2 AND CRACKED. REMOVED AND REPLACED FLOOR PANEL SRM 51-10-2, 51-10-03 REINSTALLED HAS CHANNELS, SRM 51-30-02. (M)SDR CALA9700463Floor Web · corrodedINSPECTION FOUND LEFT AFT LAV FLOOR WEB AND STRAP CORRODED FROM BS 1016 TO AFT PRESSURE BULKHEAD AT LBL ZERO. THE RIGHT AFT LAV FLOOR WEB AND STRAP WAS CORRODED FROM BS 1016 TO AFT PRESSURE BULKHEAD AT RBL ZERO. BOTH AREAS WERE REPAIRED IAW SRM 51-70-13 AND SDR CALA9700337Floor Panel · corrodedINSPECTION FOUND CABIN FLOOR PANEL CORRODED AT B.S. 1144, RBL 40. A REPAIR WAS PERFORMED IAW SRM 51-40-2 AND 51-10-2.SDR AU970246Floor · cracked(AUS) FLOOR CRACKED IN AREA OF SEAT RAIL ATTACHMENT AT REAR - SEAT RAIL HAS A RIGHT ANGLE END WHICH CUTS INTO FLOORSDR B4MR97002Floor Web · corrodedKOSC - DURING ACCOMPLISHMENT OF CORROSION TASK CARD NBR C53-224-03 PART 01 OF 02 FOUND BELOW RIGHT HAND AFT LAVATORY FLOOR WEB HAS WHAT APPEARS TO BE LEVEL 2 CORROSION, RBL 37 STA 1177 JUST FORWARD OF DITCHING PAN H5. REPAIRED IAW BOEING SRM 51-40-2. 7075-T6SDR HALA9794Floor Panel · crackedAFT CARGO PIT FLOOR PANEL AT FS 971-1047 UNDERSIDE OF FLOOR PANEL SUPPORT BRACKETS CRACKED AND BROKEN AT RIVETS AND NOT ATTACHED TO FLOOR PANEL. REMOVED SUPPORT BRACES, FABRICATED AND INSTALLED REPLACEMENT BRACES PER SRM 51-30-2, 51-10-2, 51-10-3. (M)SDR AALA970397Floor · corrodedTUL - CORROSION ON FLOOR WEB STA 1175 BL 6L (JUST FORWARD END OF VAULT DOOR THRESHOLD JOINT). REPLACED FLOOR SHEET METAL SECTION IN FRONT OF VAULT DOOR (REPAIRED PER 51-40-2) SRM. TST: 46,546 HOURS. CYCLES, 23,428. (X)SDR HALA97119Floor Panel · crackedCRACKS IN FLOOR PANEL CABIN FLOOR LINE STATION 237 TO 294, FROM CLT TO LBL 16. REMOVED, FABRICATED, INSTALLED HAT CHANNELS PER SRM 53-23-0 AND 51-30-2. (M)SDR TWAA9726007Floor · corrodedMCI - DURING OP-16, FOND CORROSION ON FLOOR MEMBRANE INBOARD OF AFT SERVICE DOOR THRESHOLD. REMOVED CORROSION PER SRM 51-10-3, PARAGRAPH 31.42. INSTALLED WEB REPAIR PER SRM 53-01, PAGE 18, FIGURE 4. (M)SDR DLM88970348Floor Membrane · crackedSUB-FLOOR MEMBRANE CRACKED LT AND RT SIDE AT STA 1290. REPLACED LT AND RT MEMBRANE PER SRM 53-05 FIG 100.SDR EIAA970018Floor Panel · corrodedSAT - DURING C-6 INSPECTION, IN MAIN CARGO COMPARTMENT FLOOR PANEL HAS HEAVY INTERGRANULAR CORROSION AND FASTENER HEADS PULLING THROUGH AT STATION 174, RBL 23, DOT NR SRT 016. REMOVED DAMAGED SECTION AND INSTALLED DOUBLER PER SRM 53-01 FIGURE NR 2. ALODINED SDR TWAA9720014Floor · corrodedMCI - DURING OP-16, FOUND CORROSION OF CABIN FLOOR MEMBRANE AT FORWARD INBOARD CORNER OF FORWARD SERVICE DOOR THRESHOLD, FS 168-207, RBL 60. REMOVED CORROSION PER SRM 51-10-3, AND REPAIRED PER SRM 53-01, FIGURE 2. (M)SDR HALA97118Floor Board · corrosionLEVEL 11 CORROSION ON FLOOR BOARD FS 200-229, X-40 - X-50. FABRICATED NEW FLOOR BOARD PER SRM 51-10-2, TREATED PER SRM 51-10-3. (M)SDR AALA970269Floor Pan · corrodedTUL - FOUND CORROSION BEYOND LIMITS 6 INCHES INBOARD OF LAV SINK DRAIN TUBE. REMOVED CORROSION AND INSTALLED DOUBLER REPAIR PER SRM 51-40-2 PAGE 1-6. (M)SDR 97ZZZX1576Structure · corrodedCOCKPIT FLOOR STRUCTURE CORRODED STA 109 CENTER AREA.SDR AWXA9700081Floor Pan · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR PAN BS 1377 TO 1439 RBL 20 WL 147. ORIGINAL THICKNESS .069 REMOVED .019 OUT OF LIMITS. REMOVED AND REPLACED WITH NEW FLOOR PAN PER SRM 53-00-53, 53-60-53, 51-40-02, 51-40-05 AND 51-40-08.SDR CKSA97008Floor Panel · damagedBASE VISIT, BS 1183 LEFT CENTER FLOOR PANEL DAMAGED. REMOVED AND REPLACED FLOOR PANEL IAW 727 BSRM 53-20-2. INSTALLED PANEL IAW AIA/EA/2499 AND EA 97-021. CORROSION CARD NR C53-224-04 PART 1 OF 1, NON-ROUTINE TASK NR 94279.SDR CKSA97007Floor Panel · damagedBASE VISIT, BS 1183 RIGHT CENTER FLOOR PANEL DAMAGED. REMOVED AND REPLACED FLOOR PANEL IAW 727 BSRM 53-20-2. INSTALLED PANEL IAW AIA/EA/2499 AND EA 97-021. CORROSION CARD NR C53-224-04 PART 1 OF 1, NON-ROUTINE TASK CARD NR 94278.SDR GTIA9700115Floor · corrodedMHV - COCKPIT FLOOR RIGHT SIDE, SMALL PAN AREA UNDER GALLEY NR 1 HAS EXFOLIATION CORROSION AT STATION 160. REMOVED DAMAGED AREA, FABRICATED NEW WEB AND INSTALLED PER SRM 53-10-1. (M)SDR AWXA9700027Floor Web · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND LT AND RT AFT LAVATORY FLOOR WEB AT THE PRESSURE BULKHEAD CORRODED. REMOVED LT AND RT FLOOR WEBS, FABRICATED NEW WEBS IAW BOEING DRAWING 65-52457, INSTALLED IAW SRM 51-40-02.SDR AWXA9700012Floor Web · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND LT AND RT AFT LAVATORY FLOOR WEB AT THE PRESSURE BULKHEAD IS CORRODED. REMOVED LT AND RT FLOOR WEBS, FABRICATED NEW WEBS IAW BOEING DRAWING NR 65-52457, INSTALLED IAW SRM 51-40-02.SDR GTIA9700103Floor · crackedMHV - FLOOR STRUCTURE, 3 INCH CRACK ON FLOOR WEB AT STATION 200 RBL 43 ZF-1. FABRICATED WEB IAW 51-10-1. REMOVED AND REPLACED WEB IAW 51-10-3, 51-30-2. (M)SDR GTIA9700102Floor · crackedMHV - TWO INCH CRACK ON FLOOR WEB STATION 218 RBL 43 ZF 1. REMOVED CRACKED FLOOR WEB, FABRICATED NEW FLOOR WEB IAW 53-10-1, INSTALLED IAW 51-10-3, 51-30-2. (M)SDR GTIA9700091Floor · corrodedMHV - FLOOR STRUCTURE HAS POPPED RIVET AT STATION 237 RBL 54 ZF1. C/T WEB HAS TWO BOLTS MISSING/CORRODED AT STATION 200 RBL 43 AND 45 ZF1. WHILE REPAIRING FASTENERS THE WEB AND GUSSET WERE FOUND TO BE CORRODED BEYOND LIMITS. REMOVED DAMAGED AREAS, FABRICATESDR CA970109007Track · broken(CAN) #3 FLOOR TRACK BROKEN OUT AT STATION 365, #1 PALLET POSITION. FORWARD LOCK DAMAGED WITHIN 40 INS OF SPLICE. TRACK REPLACED.SDR DLM88970044Floor Panel · crackedMEMBRANE CRACKED STA 1295 OUTBOARD CABIN SUBFLOOR, LT SIDE VIEWED FROM BELOW. STARTED REMOVAL OF SUBFLOOR, REMOVED MEMBRANE, INSTALLED NEW MEMBRANE. REPAIRED PER SRM 53-05 FIG 100.SDR GTIA9700083Floor Panel · peelingMHV - FLOOR PANEL NR 5 MYLAR PEEING, DOUBLER MISSING ON BOTH SIDES AND HAS SOME AREA DELAMINATING. FABRICATED AND INSTALLED (3) NEW DOUBLERS. REBOND DOUBLERS PER MM 20-20-0. (M)SDR GTIA9700078Floor Panel · delaminatedMHV - AFT FLOOR PANEL S/N 2686 AND END DELAMINATED ALONG EDGE AND CRACKED IN LOWER ANGLE ALONG DELAMINATION. REPAIRED DELAMINATION PER SRM 53-05. STOP DRILLED CRACK PER SRM 53-01 AND REPAIRED PER SRM 53-05. FABRICATED REPAIR DOUBLERS PER SRM 53-05. ALODINESDR GTIA9700077Floor Panel · crackedMHV - FLOOR PANEL NR 21 HAS 6 CRACKS IN HAT CHANNELS. REMOVED DAMAGED AREAS, FABRICATED DOUBLERS AND INSTALLED IAW SRM 53-05, 51-10-3, 51-10-4, 53-30-2. (M)SDR GTIA9700076Floorboard · crackedMHV - FLOORBOARD NR 21 HAT SECTIONS CHAFED, CRACKED AND BROKEN OUT. REPAIRED FLOORBOARD IAW 53-05, INSTALLED IAW 51-30-2. (M)SDR GTIA9700074Floor Panel · crackedMHV - FLOOR PANEL HAS BREAK OUT FROM ONE FASTENER HOLE ALONG EDGE AND TWO EACH EDGE STRIPS MISSING. FABRICATED PATCH IAW SRM 55-01. TREATED AND PRIMED PATCH IAW SRM 51-10-03. INSTALLED PATCH WITH RIVETS IAW SRM 51-30-2. FABRICATED EDGE STRIPS IAW MM 53-20-SDR GTIA9700072Floor Panel · crackedMHV - FLOOR PANEL AFT CABIN 15A IS CRACKED ON TOP SURFACE AND ONE HAT CHANNEL IS CRACKED ALONG SAME EDGE. ALSO, AT OPPOSITE END OF WHERE CRACKS ARE INSULATION BATTING UNBONDING AND PROTRUDING BEYOND EDGE. FABRICATED AND INSTALLED HAT CHANNEL REPAIRS (2) PER SDR GTIA9700071Floor Panel · delaminatedMHV - FLOOR PANEL NR 1 HAS DOUBLER DELAMINATION ON SOME AREAS, MYLAR CRACK ON 3 AREAS, DELAMINATED HAT SECTION, NUMEROUS CRACKS IN HAT SECTIONS AND CORROSION. REBONDED PER 53-20-21. DRILLED TACK RIVETS PER 51-10-4. INSTALLED RIVETS PER 51-30-3. TREATED CORSDR GTIA9700070Floor Panel · tornMHV - FLOOR PANEL AFT CABIN FASTENER HOLE IS TORN OUT AT CORNER. REPAIRED BY FABRICATING RD DOUBLER. ALODINE AND PRIMED PER SRM 51-10-3 AND DRILLED AND COUNTERSUNK PER SRM 51-10-4 AND INSTALLED RIVETS PER SRM 51-30-2. REPAIRED PER SRM 53-05. (M)SDR GTIA9700069Floor Panel · crackedMHV - FLOOR PANEL NR 17 HAS CRACK AT FORWARD SIDE CENTER BESIDES SCREW HOLES. INSTALLED SKIN DOUBLER IAW 55-01 FIG 2. (M)SDR GTIA9700067Floor Panel · crackedMHV - LAVATORY FLOOR PANEL NR 8 HAS A CRACK ON RIGHT AFT CORNER, FORWARD SIDE HAS 4 FASTENER HEAD BROKEN. STOP DRILLED CRACK, FABRICATED DOUBLER, INSTALLED DOUBLER IAW 53-01, 53-05, 51-10-3, 51-30-3. (M)SDR GTIA9700066Floor Panel · crackedMHV - FLOOR PANEL NR 13, LEFT FORWARD CORNER HAS CRACK. STOP DRILLED CRACK AND BONDED DOUBLER IAW 53-20-1. (M)SDR GTIA9700065Floor Panel · delaminatedMHV - RIGHT FORWARD OUTBOARD WING BOX FLOOR PANEL HAS DELAMINATING DOUBLERS, TWO SECTION DOUBLERS MISSING (TWO EACH) SPACERS MISSING AT END OF U-CHANNEL. REPLACE MISSING SPACERS AT END OF U-CHANNEL. REBOND DOUBLER PER MM 53-20-1. FABRICATED AND INSTALLED NESDR GTIA9700063Floor Panel · corrodedMHV - FLOOR PANEL NR 16 FORWARD HAS LIGHT CORROSION BETWEEN DOUBLER AND FORWARD END OF PANEL, ALSO, CRACK FROM FASTENER TO OUTSIDE OF PANEL. INSIDE IS MISSING INSULATION AND HAS LOOSE TAPE. BLENDED CORROSION (.002 REMOVED PER 51-10-3, WITHIN LIMITS PER 51-10
Back to JASC 5321