SDR SWAA2023070355718Web · corrodedCORROSION ON PASSENGER CABIN FLOOR SHEAR WEB AT BS 1016+9; LBL 20 - LBL 29; WL 208.<[01] NO ALLOWABLE LIMITS FOUND;REMOVED DAMAGE ON PASSENGER CABIN FLOOR SHEAR WEB AT BS 1016+9; LBL 20 - LBL 29; WL 208 9.5'X2' AREA I.A.W SRM 51-10-02-0G-0;[02] REQUEST HFEC TOSDR SWAA2023062955743Floor Support · crackedPASSENGER CABIN FLOOR SUPPORT BS 927-947; BL 0; WL 208 IS CRACKED.<[01] NO ALLOWABLE LIMITS FOUND ON SRM ;REPLACEMENT OF THE PART IS APPLICABLE I.A.W SRM 51-10-02-0G-0 PAR 9.C;[02] REMOVED PASSENGER CABIN FLOOR SUPPORT BS 927-947; BL 0; WL 208 IAW SRM 51-40-02SDR SWAA2023062955749Seat Track · elongatedPASSENGER CABIN SEAT TRACK BS 923; RBL 25 TRACK OUTBOARD FLANGE; WL 208 HAS ELONGATED HOLE.<[01] NO SRM ENTRIES FOUND REPLACEMENT OF THE PART IS APPLICABLE PER SRM 51-10-02-0G-0 PAR 9.C;[02] REMOVED PASSENGER CABIN SEAT TRACK SECTION BS887-BS927; RBL 25; WL 20SDR SWAA2023062955755Seat Track · elongatedPASSENGER CABIN SEAT TRACK BS 923; RBL 45 TRACK INBOARD FLANGE; WL 208 HAS ELONGATED HOLE.<[01] NO SRM ENTRIES FOUND REPLACEMENT OF THE PART IS APPLICABLE PER SRM 51-10-02-0G-0 PAR 9.C;[02] REMOVED PASSENGER CABIN SEAT TRACK SECTION BS887-BS927; RBL 25; WL 208SDR SWAA2023061255073Battery Pack · inoperativeSEVERAL EMERGENCY LIGHTS INOPERATIVE AT MAIN PASSENGER CABIN AND EXTERNAL FUSELAGE<[01] REMOVED AND REPLACED BATTERY PACK M1673 PER AMM 33-51-06-960-805. TEST NORMAL;[02] TROUBLE SHOOT PER FIM 33-50 TASK 801 AND FOUND M1673 AND M1675 DEFECTIVES. REMOVED AND RESDR SWAA2023060556065Slide · out of adjustAFT ENTRY DOOR SLIDE FLAP CONTACTING FRAME WHEN CLOSING.<[01] ADJUSTED AFT ENTRY DOOR SLIDE IN CASE. OPS NORMAL. REF AMM25-66-01.SDR SWAA2023071754659Bulkhead · crackedBS663 COMPOSITE VAPOR BARRIER BULKHEAD IS CRACKED AT WL 152; RBL 32.<[01] IDENTIFIED 663 BULKHEAD R/H VAPOR BARRIER MATERIAL IAW SRM 57-10-10-0I-2 TABLE 2 FIGURE 2 ITEM 4. DAMAGE AT DISCREPANT LOCATION EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 57-10-10-1A-2 PARASDR SWAA2023070555010Stringer · corrodedCORROSION ON STRINGER AT AREA AFT OF FWD CARGO BAY BS535 S-23R WL164.<[01] CUT OUT DAMAGE SECTION FROM BS 500D + 3 TO 540 PER REF SRM 51-10-02;[02] REMOVED SHEAR TIE BETWEEN STR 23-22 ABD BS 520 PER REF SRM 51-40-02;[03] REQUIRE NDI TO VERIFY CRACK FREE CONDITSDR SWAA2023070555116Fitting · corrodedCORROSION ON STRINGER END FITTING AT AREA AFT OF ACB BS1015 RBL4 WL189.<[01] EVALUATED EXFOLIATION CORROSION AT STRINGER END FITTING FOUND TO BE OUT OF LIMITS NO FOUND LIMITS ON SRM REPAIR BY REPLACEMENT OF THE PART PER SRM 51-10-02-0G-0 STEP 9;[02] REMOVED STSDR SWAA2023070554705Floor Panel · pulledAFT FLOOR PANEL 242RF UPPER SKIN HAS PULLED STRANDS.<[01] AFT FLOOR PANEL 242RF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023070554709Floor Panel · pulledAFT FLOOR PANEL 241AAF UPPER SKIN HAS PULLED STRANDS.<[01] DUE TO AMOUNT OF DAMAGE FLOOR PANEL 241AAF WILL BE REPLACED WITH NEWLY FABRICATED FLOOR PANEL IAW SRM 53-00-50-2R-0 PARA 1A NOTE. <BR><BR>FABRICATED PANEL USING BMS 4-17 TY6 LOT#1526676-1; APPLIED ALL SDR SWAA2023070554719Floor Panel · pulledFWD FLOOR PANEL 221BF UPPER SKIN HAS PULLED STRANDS.<[01] FWD FLOOR PANEL 221BF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023070554721Floor Panel · pulledFWD FLOOR PANEL 221FF UPPER SKIN HAS PULLED STRANDS.<[01] FWD FLOOR PANEL 221FF UPPER SKIN WITH PULLED STRANDS WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023070554722Floor Panel · brokenFWD FLOOR PANEL 221GF FWD O/B TANG IS BROKEN.<[01] FWD FLOOR PANEL 221GF WITH BROKEN FWD O/B TANG WAS REPLACED WITH A SERVICEABLE FLOOR PANEL PER SRM 51-10-02-0G-0 PARA 9.A.1 DUE TO AMOUNT OF ALL DAMAGE.;[02] VERIFIED CORRECTIVE ACTION #1SDR SWAA2023070555112Angle · crackedCABLE INTERCOSTAL ATTACH ANGLE IS CRACKED IN RADIUS BS 692; RBL 1; WL 206<[01] REMOVED DAMAGED CABLE INTERCOSTAL ATTACH ANGLE BS 692; RBL 1; WL 206 IAW SRM 51-40-02;[02] FORMED NEW INTERCOSTAL ATTACH ANGLE BS 692 ; RBL 1 WL 206 MATERIAL USED 7075T0 ; 0.050' CLSDR SWAA2023070565053Floor Panel · pulledAFT FLOOR PANEL 241XF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED 241XF PANEL IAW SRM 53-00-50-0I-1 PARA FIGURE 6; TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>WILL PERFORM WORK IAW SRM 53-00-50-2R-1<BR>REMOVED 2SDR SWAA2023070554702Floor Panel · pulledAFT FLOOR PANEL 241ACF UPPER SKIN HAS PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL FABRICATION IAW EA 23-153-01769;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070554703Floor Panel · pulledAFT FLOOR PANEL 241ADF UPPER SKIN HAS PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL FABRICATION IAW EA 23-153-01770;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070554704Floor Panel · pulledAFT FLOOR PANEL 241AEF UPPER SKIN HAS PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL FABRICATION IAW EA 23-153-01781;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070554713Floor Panel · pulledAFT FLOOR PANEL 242TF UPPER SKIN HAS PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL FABRICATION IAW EA 23-153-01777;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070565056Floor Panel · crackedAFT FLOOR PANEL 241ABF LOWER SKIN IS CRACKED AT THE FWD O/B CORNER.<[01] IDENTIFIED PANEL 241ABF IAW SRM 53-00-50-0I-1 FIGURE 6; TABLE 6.<BR><BR>DAMAGE ON PANEL IS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4 F.<BR><BR>DAMAGE TO BE REPAIRED PER SRM 53-SDR SWAA2023070565057Floor Panel · pulledAFT FLOOR PANEL 242SF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED 242SF PANEL IAW SRM 53-00-50-0I-1 PARA FIGURE 6; TABLE 6.<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4.F.<BR>WILL PERFORM WORK IAW SRM 53-00-50-2R-1<BR>REMOVED 1SDR SWAA2023070565058Floor Panel · pulledAFT FLOOR PANEL 242UF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 242UF IAW SRM 53-00-50-0I-1 FIG 6 TABLE 6 AND BOEING DWG 147A5810-95.<BR><BR>FOUND DAMAGE TO UPPER SURFACE SKIN PLIES TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PASDR SWAA2023070554706Floor Panel · pulledAFT FLOOR PANEL 242VF UPPER SKIN HAS PULLED STRANDS.<[01] VERIFIED COMPLETION OF PANEL FABRICATION IAW EA 23-153-01779;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070565052Floor Panel · pulledAFT FLOOR PANEL 242WF UPPER AND LOWER SKINS HAVE PULLED STRANDS.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 SHEET 1; FIGURE 6; <BR>TABLE 6; AND BOEING DWG DOC: 147A5810 ID: 0010.<BR><BR>PANEL DAMAGE TO UPPER SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMISDR SWAA2023070565062Floor Panel · pulledFWD FLOOR PANEL 221AF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 SHEET 1; FIGURE 2; TABLE 2; <BR>AND BOEING DWG DOC: 141A5810 ID: 0728.<BR><BR>PANEL DAMAGE TO UPPER SKIN PLIES IS OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM <SDR SWAA2023070565059Floor Panel · pulledFWD FLOOR PANEL 221DF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 221DF MATERIAL IAW SRM 53-00-50-0I-1 FIG 2; TABLE 2.<BR><BR>CLEANED PANEL REPAIR AREA IAW SRM 53-00-50-2R-0 PARA 5. A. (1).<BR><BR>FOUND DAMAGE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-SDR SWAA2023070565060Floor Panel · pulledFWD FLOOR PANEL 222AF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED PANEL 222AF IAW SRM 53-00-50-0I-1.<BR>FOUND DAMAGE ON UPPER SURFACE TO BE BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1.PARA 4.F.<BR>DAMAGE SHOULD BE REPAIRED PER SRM 53-00-50-2R-1.<BR><BR>RESDR SWAA2023070565061Floor Panel · pulledFWD FLOOR PANEL 222BF UPPER SKIN HAS PULLED STRANDS.<[01] IDENTIFIED FLOOR PANEL 222BF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1 <BR><BSDR SWAA2023070355252Attach Angle · corrodedCORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS767 TO BS787 RBL21 WL156<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070354817Stringer · corrodedCORROSION ON STRINGER S-26R FROM STA 520+18 TO STA 540.<[01] CORROSION FOUND OUT OF LIMITS ON STRINGER S-26R BS 535 SKIN ATTACHMENT FLANGE 100% OF MATERIAL THICKNESS LOSS L=1' X W=0.75' IAW SRM 53-00-03-1A-1.;[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1 RESDR SWAA2023070355251Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767+3 TO BS794 RBL22 WL156<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] UPDATE TO CORRECTSDR SWAA2023070355253Angle · corrodedCORROSION AFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS MULTIPLE AREAS UNDER NUT PLATES BS767 TO BS787 RBL21 WL156<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1;[03] UPDATE TO CORRESDR SWAA2023070355299Door · corrodedCORROSION ON FWD ENTRY DOOR MOPSILL BS 300-312; LBL 65; WL 208.<[01] VERIFIED APPLICABILITY OF SRM 53-10-15-1A-1; REMOVED CORROSION OF FWD ENTRY DOOR MOPSILL BS 300-312; LBL 65; WL 208 AND FOUND OUT OF LIMITS; MATERIAL THICKNESS 0.090' REMOVED MATERIAL 0.020' SDR SWAA2023070355250Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767+3 TO BS794 RBL22 WL156<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION 1SDR SWAA2023070355025Skin · crackedRH HORIZONTAL STABILIZER LOWER SKIN (INSPECTION OF SKIN PANEL OUTBOARD OF SB 737-55-1096) .5' CRACK FOUND 26.8' FROM FWD SIDE AT STA 187.70<[01] REMOVED PANEL 341BZ IAW SOPM 20-50-01 TO ACCESS REPAIR.;[02] REQUEST HFEC INSPECTION TO MARK END OF CRACK.;[03] ACCSDR SWAA2023062955205Floor Panel · pulledAFT CABIN FLOOR PANEL 241VF HAS A PULLED THROUGH INSERT HOLE<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW FLOOR PANEL USING BMS4-23 TYPE II LOT 1525675-1 AND BMS5-107 LOT AK2KP8383K-1 RESIN; CURED RESIN WITH A HEAT LAMP USING THERMOMSDR SWAA2023062955231Floor Panel · brokenFWD CABIN FLOOR PANEL 221BF AFT O/B CORNER IS BROKEN (TANG)<[01] IDENTIFIED PANEL 221BF IAW SRM 53-00-50-0I-1 FIGURE 2. DAMAGE IS BEYOND ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARAGRAPH 4.E.(2).(B) AND WILL BE REPAIRED IAW SRM 53-00-50-2R-6. REMOVED NUMEROUS ISDR SWAA2023062955233Floor Panel · brokenFWD CABIN FLOOR PANEL 221GF FWD O/B CORNER IS BROKEN (TANG)<[01] IDENTIFIED FLOOR PANEL 221GF IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR><BR>DAMAGE EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B<BR><BR>DAMAGE TO BE REPAIRED IAW SRM 53-00-50-2R-1SDR SWAA2023062955204Floor Panel · pulledAFT CABIN FLOOR PANEL 241VF HAS A PULLED THROUGH INSERT HOLE<[01] DUE TO THE EXTENT OF ALL OF THE DAMAGE; DECIDED TO FABRICATE A NEW FLOOR PANEL USING BMS4-23 TYPE II LOT 1525675-1 AND BMS5-107 LOT AK2KP8383K-1 RESIN; CURED RESIN WITH A HEAT LAMP USING THERMOMSDR SWAA2023062954606Floor Panel · pulledFLOOR PANEL 232RF UPPER SKIN HAS PULLED STRANDS.<[01] DUE TO THE EXTENT OF DAMAGE; FABRICATED NEW FLOOR PANEL 232RF USING BMS 4-23TY2 LOT#1525675-1. INSTALLED INSERTS USING BMS 5-107 LOT#AK2KP8383K-1; CURED WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023; APPLIED SDR SWAA2023062954982Angle · crackedCRACKED INTERCOSTAL AT PASSENGER CABIN BS500D+6 BL0 WL208.<[01] REMOVED PASSENGER CABIN UPPER ANGLE INTERCOSTAL FROM BS500D - BS420; BL 0; PER SRM 51-40-02-0G-0.<BR>RECEIVED FROM TOOL ROOM NEW INTERCOSTAL UPPER ANGLE P/N 143A5410-170; LOCATED AND DRILL PER SRMSDR SWAA2023062954980Intercostal · crackedCRACKED INTERCOSTAL AT PASSENGER CABIN BS380+14 LBL13 WL208.<[01] DRILLED FASTENERS AND REMOVED INTERCOSTAL IAW SRM 51-40-02;[02] CERTIFY;[03] UPDATED MEASUREMENT TABLE;[04] RECEIVED NEW ANGLE PER CUSTOMER RO: N923207-SWA;[05] VERIFIED CORRECTIVE ACTION 4;[06]SDR SWAA2023062954983Intercostal · crackedCRACKED INTERCOSTAL AT PASSENGER CABIN BS380+14 BL0 WL208.<[01] REMOVED PASSENGER CABIN UPPER ANGLE INTERCOSTAL FROM BS380 - BS400; BL 0; PER SRM 51-40-02-0G-0<BR>RECEIVED FROM TOOL ROOM NEW INTERCOSTAL UPPER ANGLE P/N 143A5410-170; LOCATED AND DRILL PER SRM 5SDR SWAA2023062954825Stringer · crackedSTRINGER S-24L IS CRACKED AT STA 540.<[01] CRACK FOUND OUT OF LIMITS ON STRINGER S-24L BS 535 SKIN ATTACHMENT FLANGE 100% OF MATERIAL THICKNESS L=0.5' IAW SRM 53-00-03-1A-1;[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1 REP.1. FOR STRINGER S-24L BS 535 SKIN SDR SWAA2023062954821Stringer · crackedSTRINGER S-25R IS CRACKED AT STA 540.<[01] REMOVED DAMAGED SECTION OF STRINGER S-25R BS 500D+10' - BS 535 IAW SRM 53-00-03-2R-1 REP.1 PAR 4 A-B AND EA 23-153-01768;[02] PERFORMED A GVI ON REPAIR AREA OF STRINGER S-25R BS 500D+10' - BS 535 AND NOT FOUND ADDITIOSDR SWAA2023062954823Stringer · crackedSTRINGER S-26L IS CRACKED AT STA 540.<[01] CRACK FOUND OUT OF LIMITS ON STRINGER S-26L BS 535 SKIN ATTACHMENT FLANGE 100% OF MATERIAL THICKNESS L=0.5' IAW SRM 53-00-03-1A-1;[02] VERIFIED APPLICABILITY OF SRM 53-00-03-2R-1 REP.1. FOR STRINGER S-26L BS 535 SKIN SDR SWAA2023062954819Stringer · corrodedCORROSION ON STRINGER S-23R FROM STA 520+18 TO STA 540.<[01] CORROSION FOUND OUT OF LIMITS ON STRINGER S-23R BS 535 SKIN ATTACHMENT FLANGE 100% OF MATERIAL THICKNESS LOSS L=1' X W=0.5' IAW SRM 53-00-03-1A-1;[09] RECEIVED PARTS NEW STRINGER SECTION OF STR-23R RSDR SWAA2023062955285Floor Support · crackedPASSENGER CABIN FLOOR SUPPORT BS 380-400; RBL 10; WL 208 IS CRACKED.<[01] NO ENTRIES FOUND ON SRM FOR PASSENGER CABIN FLOOR SUPPORT BS 380-400; RBL 10; WL 208 PART TO BE REMOVED AND REPLACED PER SRM 51-10-02-0G-0 PAR 9.C;[02] REMOVED PASSENGER CABIN FLOOR SUPPSDR SWAA2023062955287Floor Support · crackedPASSENGER CABIN FLOOR SUPPORT BS 380-400; LBL 15; WL 208 IS CRACKED.<[01] NO ENTRIES FOUND ON SRM FOR CRACKED INTERCOSTAL UPPER ATTACH ANGLE STA 380-400; LBL 15; WL 208 PART TO BE REMOVED AND REPLACED PER SRM 51-10-02-0G-0 PAR 9.C;[02] REMOVED CRACKED INTERCOS
Back to Boeing 737-7H4