Boeing 757-2S7
Service difficulty reports · 1,282
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572S7' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '7572S7' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AWXA9700126Frame · crackedDURING ROUTINE MAINTENANCE CHECK, FOUND E/E BAY DOOR FRAME CRACKED THROUGH FASTENER HOLE AT BUMPER PAD ON RT FWD CORNER, PANEL NR 119BL. FABRICATED AND DRILLED REPAIR DOUBLER AND INSTALLED PER ER 5-52-41-01.SDR AWXA9700143Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON CARGO BAY FLOOR STRINGER BS 1564 TO 1570 RBL 2 WL 152. REMOVED, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 51-70-12.SDR AWXA9700134Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR SUPPORT STRINGER BS 1470, RBL 2. REMOVED DAMAGED FLOOR SUPPORT SECTION. FABRICATED AND INSTALLED NEW SUPPORT PER IAW, SRM 51-70-12.SDR AWXA9700125Seat Track · gougedDURING ROUTINE MAINTENANCE CHECK, FOUND SEAT TRACK GOUGED AT BS 1480, LBL 45, WL 208. BLENDED SEAT TRACK, FOUND TO BE OUT OF LIMITS. REMOVED DAMAGED SEAT TRACK. FABRICATED AND INSTALLED NEW SEAT TRACK IAW, SRM 53-00-52.SDR AWXA9700114Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR SUPPORT BS 1470, LBL 16. REMOVED CORRODED SECTION. FABRICATED AND INSTALLED REPAIR PARTS ON FLOOR SUPPORT STRINGER AT BS 1470, LBL 16 AS PER SRM 51-70-11.SDR AWXA9700122Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT STRINGER BS 1510, RBL 2. REPAIRED FLOOR SUPPORT STRINGER BS 1510, RBL 2 PER SRM 51-7-012.SDR AWXA9700115Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT SIDE PANEL BS 1410 - 1530, LBL 20. REMOVED DAMAGED AREA OF FLOOR. FABRICATED AND INSTALLED SIDEWALL SUPPORT IAW, SRM 51-40-2.SDR AWXA9700137Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT STRINGER BS 1510, LBL 7, WL 146. REMOVED DAMAGE 2 BY 1 TO MAXIMUM DEPTH OF .017 FROM ORIGINAL THICKNESS OF .063. OUT OF LIMITS PER SRM 53-00-03. REPAIRED FLOOR SUPPORT STRINGERSDR AWXA9700136Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LWR SURFACE (AFT CARGO) FLOOR SUPPORT STRINGER BS 1328 - 1331, LBL 11. REPAIRED CORRODED FLOOR SUPPORT STRINGER BS 1290 TO 1343, LBL 11 AS PER SRM 51-70-12.SDR AWXA9700135Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1343 - 1369.5, RBL 7 CORRODED. REMOVED, FABRICATED AND INSTALLED FLOOR SUPPORT STRINGER FROM BS 1343 TO BS 1369.5, RBL 7.SDR AWXA9700133Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE (AFT CARGO) FLOOR SUPPORT STRINGER BS 1510, RBL 11. REPAIRED FLOOR SUPPORT STRINGER BS 1510, RBL 11 PER SRM 51-70-12.SDR AWXA9700132Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1347, RBL 10. REMOVED DAMAGED FLOOR SUPPORT STRINGER AND INSTALLED FABRICATED FLOOR SUPPORT STRINGER BS 1343 - 1460, RBL 10.45 PER SRM 51-10-00, SRM 51-30-02 AND SSDR AWXA9700131Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1328 - 1337, RBL 10. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 51-70-12.SDR AWXA9700130Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT STRINGER BS 1328 - 1334, RBL 15. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 51-70-12.SDR AWXA9700129Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1343 - 1445, RBL 15 CORRODED. REPAIRED DAMAGED FLOOR SUPPORT STRINGER AT BS 1343 - 1445, RBL 15, IAW, SRM 51-70-11, 51-40-02.SDR AWXA9700128Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1328 - 1331, RBL 2 HAS CORROSION ON LOWER SURFACE, AFT CARGO. REMOVED STRINGER FROM BS 1200 - BS 1343. FABRICATED AND INSTALLED REPAIR PARTS IAW, SRM 51-70-12.SDR AWXA9700127Floor Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT SIDE PANEL BS 1260 - 1310, RBL 20 HAS CORROSION LOWER SURFACE. REPAIRED DAMAGED FLOOR SUPPORT AT BS 1260 - 1310, RBL 20, IAW 53-00-53, 51-70-11, 51-40-02.SDR AWXA9700124Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT BS 1470, RBL 10. REMOVED DAMAGED AREA. FABRICATED REPAIR PARTS AND INSTALLED PER SRM 51-40-02.SDR AWXA9700123Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE (AFT CARGO) FLOOR SUPPORT STRINGER BS 1328 - 1334, LBL 16. REMOVED DAMAGED AREA IAW, SRM 51-40-02. FABRICATED AND INSTALLED REPAIR PARTS.SDR AWXA9700120Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1470, RBL 15 CORRODED. REMOVED CORRODED SECTION. FABRICATED AND INSTALLED REPAIR PART IAW, SRM 51-70-11.SDR AWXA9700119Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1495 - 1548, RBL 6 CORRODED. REPAIRED FLOOR SUPPORT STRINGER AT BS 1495 - BS 1548, RBL 6 PER SRM 51-70-12.SDR AWXA9700118Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT STRINGER BS 1495 - 1549, LBL 3, WL 146. REMOVED DAMAGE IN AREA 2 BY 1. FOUND CORROSION TO EXTEND COMPLETELY THROUGH MATERIAL. OUT OF LIMITS PER SRM 53-00-03. REPAIRED FLOOR SUSDR AWXA9700117Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT STRINGER BS 1328 - 1334, LBL 7 HAS CORROSION ON LOWER SURFACE (AFT CARGO). REMOVED CORRODED FLOOR SUPPORT STRINGER AND FABRICATED REPAIR PARTS BS 1242 - 1343, LBL 7 PER SRM 51-70-12.SDR AWXA9700116Side Panel · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SUPPORT AT AFT CARGO DOOR BS 1380 - 1440, RBL 20 HAS CORROSION, UPPER AND LOWER SURFACES F AND R AFT CARGO FLOOR SUPPORT BS 1380 - 1440, RBL 20, IAW, SRM 51-40-02 AND OHM 20-50-01.SDR AWXA9700113Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1510, LBL 12, WL 146. REMOVED DAMAGE IN AREA OF 2 BY 1 TO A MAXIMUM DEPTH OF .021 FROM ORIGINAL OF .063. OUT OF LIMITS PER SRM 53-00-03. REPAIRED FLOOR SUPPORT SSDR AWXA9700112Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1328 - 1331, LBL 3, WL 146. REMOVED CORROSION FROM AREA 7 BY 1 TO A MAXIMUM DEPTH OF .025 FROM ORIGINAL THICKNESS OF .063. OUT OF LIMITS IAW SRM 53-00-03. REPAIRSDR AWXA9700138Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR SIDEWALL SUPPORT PANEL CORRODED BS 1310 - BS 1380, RBL 20. CUT OUT DAMAGED SECTION, FABRICATED AND INSTALLED NEW PART PER AWER 5-53-10-01.SDR AWXA9700121Stringer · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE FLOOR SUPPORT STRINGER BS 1470, RBL 7. REMOVED DAMAGED SECTION. FABRICATED AND INSTALLED REPAIR PARTS IAW, SRM 51-70-11.SDR AWXA9700073Door Slide · blownDURING MAINTENANCE PROCEDURE, R-1 DOOR SLIDE INADVERTENTLY BLOWN. REMOVED AND REPLACED EVACUATION DOOR SLIDE PER BMM 25-66-01. REMOVED AND REPLACED EMERGENCY POWER RESERVOIR PER BMM 52-11-30. PART TOTAL CYCLES, 9,299.SDR AWXA9700081Floor Pan · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR PAN BS 1377 TO 1439 RBL 20 WL 147. ORIGINAL THICKNESS .069 REMOVED .019 OUT OF LIMITS. REMOVED AND REPLACED WITH NEW FLOOR PAN PER SRM 53-00-53, 53-60-53, 51-40-02, 51-40-05 AND 51-40-08.SDR AWXA9700086Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND AFT CARGO BAY SIDEWALL TO FLOOR SUPPORT PLATE IS CORRODED AT RBL 30, BS 1530. REPLACED SIDE WALL TO FLOOR SUPPORT IAW SRM 51-70-11.SDR AWXA9700085Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED FROM BS 1543 TO 1640 RBL 20 WL 147. REMOVED, FABRICATED AND REPLACED FLOOR TO SIDEWALL SUPPORT FROM BS 1543 TO 1640 RBL 20 WL 147.SDR AWXA9700084Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED FROM BS 1309 TO 1410 LBL 20 WL 147. REMOVED, FABRICATED AND REPLACED FLOOR TO SIDEWALLL SUPPORT IN AFT CARGO BAY FROM BS 1309 TO BS 1410 LBL 20 WL 147.SDR AWXA9700083Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT IS CORRODED FROM BS 1439 TO 1513 RBL 20 WL 147. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 51-70-11, 53-00-53.SDR AWXA9700082Support · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT CORRODED FROM BS 1410 TO 1540 LBL 20 WL 147. REMOVED, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 53-00-53, 51-40-02, ER 5-53-10-01.SDR AWXA9700080Mopsill · corrodedDURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON MOPSILL AT R-3 DOOR STA 1320 TO 1350 WL 208 RBL 62. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 51-70-12.SDR AWXA9700005Downlock Pin · not removedAIR TURNBACK, AFTER DEPARTURE RECEIVED GEAR DISAGREE AND GEAR DOORS EICAS MESSAGE. BURNED FUEL DOWN TO 46,000 LBS. LANDED OVERWEIGHT AT 220000 LBS. FOUND DOWNLOCK PIN INSTALLED IN NOSE GEAR. REMOVED DOWNLOCK PIN, PERFORMED OVERWEIGHT INSPECTION PER CARD I8SDR AWXA9600729Switch · inoperativeDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY TEST BUTTON ON FORWARD CSR SEAT INOPERATIVE. REMOVED AND REPLACED THE FORWARD ATTENDENT'S PANEL EMERGENCY LIGHT SWITCH, SYSTEM OPERATIONS CHECKED NORMAL.SDR AWXA9600727Switch · inoperativeDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY TEST BUTTON ON FWD CSR SEAT INOPERATIVE. REMOVED AND REPLACED THE FWD ATTENDANT'S PANEL EMERGENCY LIGHT SWITCH, SYSTEM OPERATIONS CHECK NORMAL.SDR AWXA9600725Wire · brokenDURING ROUTINE MAINTENANCE CHECK, FOUND SEAT 31 A, B, C EMERGENCY LIGHT INOPERATIVE. RECONNECTED WIRING, OPERATIONS CHECK GOOD.SDR AWXA9600718Connector · dirtyCREW REPORT ON FINAL, FIRST OFFICER REQUESTED CAPTAIN TO RETURN RUDDER TRIM TO ZERO. CAPTAIN REPORTED WITH TRIM AT 1.5 UNITS TO RIGHT, THE RUDDER TRIM WOULD NOT RESET. CAPTAIN SELECTED TO LEFT, NO MOVEMENT, RESELECTED TO RIGHT, NO MOVEMENT. AIRCRAFT LANDED SDR AWXA960644Pin · unseatedPHX - FLT 25 - DURING ROUTINE MAINTENANCE CHECK, FOUND ROW 32 R SEAT MOUNTED EMERGENCY LIGHT INOP. FOUND PIN NOT SEATED AT SEAT 32C. RESEATED PIN. OPERATIONS CHECK GOOD. (M)SDR AWXA960612Circuit Card · failedORD - FLT 2011 - PIREP REPORTED WHEEL WELL FIRE WARNING LIGHT, IN CURISE AT 350 FL (EICAS BELLS AND ASSOCIATED WARNINGS) AIR SPEED OK, GEAR DROPPED AND ALL WARNINGS EXTINGUISHED. AIRCRAFT DIVERTED INTO ORD. LANDED OVERWEIGHT WITH NO OTHER FIRE WARNING INDICASDR AWXA960582Cable · brokenPHX - FLT 10 - DURING ROUTINE MAINTENANCE CHECK, FOUND R2 DOOR GIRT BAR RELEASE CABLE BROKEN. REMOVED AND REPLACED CABLE. (M)SDR AWXA960541Oven · dirtyPHX - FLT 25 - INBOARD OVEN IN FORWARD GALLEY PRODUCED SMOKE WHEN TURNED ON TO HEAT MEALS. CLEANED FOIL FROM OVEN. OPERATES GOOD. (M)SDR AWXA960619Seat Track · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON SEAT TRACK BS 397, RBL 45, WL 208. REMOVED AND REPLACED SEAT TRACK PER IAW SRM 51-40-02 AND SRM 51-40-00. (M)SDR AWXA960618Floor Beam · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM BS 377, RBL 2, WL 208. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 53-00-51 AND 51-20-01. (M)SDR AWXA960617Seat Track · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CEHCK, FOUND CORROSION ON SEAT TRACK BS 397, RBL 24, WL 208. REMOVED AND INSTALLED REPAIR PARTS PER SRM 51-40-02. (M)SDR AWXA960616Floor Beam · corrodedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR BEAM AT STATION 324 HAS CORROSION AT RBL 51 TO RBL 65, WL 208. FABRICATED, ALODINED, PRIMED AND INSTALLED PARTS PER ER 5-23-12-06 AND TCO PAN 96-1358RR-8110-3. (M)SDR AWXA960615Skin · dentedPAE - FLT 7825 - DURING ROUTINE MAINTENANCE CHECK, FOUND TWO DENTS IN SKIN ON LEFT AFT FUSELAGE BETWEEN BS 1500 AND 1520, BETWEEN STRINGER 26L AND STRINGER 27L. CUT OUT DAMAGE, FABRICATED PARTS AND INSTALLED PER SRM 53-00-01 AND ER 5-53-35-02. (M)
Back to Boeing 757-2S7