SDR DLM90030795Engine · fireRAMP AND FLEET SERVICE REPORT NR 1 ENG TAIL PIPE FIRE ON SHUTDOWN. REF ERA087224-14 NO COKING FOUND IN NR 5 BEARING SCAV TUBE ENG, LEAK AND OPS NORM PER PFHB.SDR DLM90030770Control Unit · failedLT ENG GEN INOPERATIVE REPLACED EPCU AND LT SYS GEN RELAY ELECTRICAL SYS OPS NML.SDR DLM90030743Wire · damagedEMERGENCY CABIN LIGHT L2-746 WOULD NOT ILLUMINATE - FOUND A OPEN WIRE AT L2474A16N ALSO FOUND POWER SUPPLY B5-227 WITH A SUSPECTED BLOWN INTERNAL FUSE - REPAIRED WIRE AND REPLACED POWER SUPPLY / OPERATION NOW NORMAL.SDR UIA9216Bearing · making metalIN FLT, LT ENG OIL STRAINER CLOG MESSAGE SHOW ON EOAP AND OIL PRESSURE DROP TO (0) FAST, FLT CREW SHUTDOWN THE ENG MANUALLY, A/C DIVERTED ON BKI. METAL CHIP WAS FOUND ON MASTER MCD AND NR 1, 2, 3 BEARING COMPARTMENT DAMAGE. THE AIRCRAFT REPLACED THE NR 1 ESDR DLM90030660Seal · leakingNOSE GEAR INDICATION SHOWED IT DID NOT RETRACT AFTER TAKEOFF. THERE WAS THE ASSOCIATED NOISE WITH AN EXTENDED NOSE GEAR. THE HANDLE WAS LOWERED ALL GEAR DOWN/LOCKED. A NORMAL LANDING WAS PERFORMED. FOUND NOSE STRUT SERVICING VALVE SEAL LEAKING,STRUT WAS FSDR DLM90030614Generator · crackedON TAKEOFF ROLL PILOT ABORTED TAKEOFF WHEN HE GOT A RT GEN OVERHEAT MESSAGE AND A RT GEN FILTER MESSAGE. REPLACED VSCF FOR CRACKED HOUSINGSDR DLM90030569Pump · malfunctionedUPON SHUTDOWN AT GATE LEFT ENG HAD SMOKE AND SOME FLAME AROUND CORE ENGINE IN THE REAR. PERFORMED TS PER AMM 71-09 PG 9, RAN ENG NO FURTHER SMOKE OR FLAME OBSERVED. ALL INSP GOOD PER M/M. MTC STILL IN WORK DUE HISTORY R&I OIL SCAVENGE PUMP. REPLACED ENGINESDR DLM90030567Strut · leakingAFTER TAKEOFF NOSE GEAR UNSAFE LIGHT STAYED ILLUMINATED. CYCLED GEAR IAW POM GEAR REMAINED UNSAFE. FOUND NOSE STRUT LEAKING. REPACKING NOSE STRUT.SDR DLM90030511Generator · inoperativeSHORTLY AFTER T/O L GEN OFF MSG AND L AC POWER FAULT MSG APPEARED ON OAP. ISOLATED LT GEN PER CHECKLIST AND RETURNED TO SLC SENCE APU WAS ALSO INOP. STATUS MSG SHOWED L ELEC SYSTEM FAIL. REPLACED LEFT GEN CONVERTER RAN ENG GEN OPS NORMAL OK FOR SVC.SDR DLM90030483Power Supply · inoperativeF/C EMERGENCY LIGHTS INOP. REPLACED POWER SUPPLY.SDR DLM90030441Transmitter · corrodedPYLON FLAP FAULT EOAP MESSAGE ILLUMINATED AT 100KTS ON TAKEOFF ROLL. AIRCRAFT TAKEOFF REJECTED AND RETURNED TO BLOCK AT GATE C-10. FOUND LEFT ELEVATOR POSITION SENSOR OUT OF RIG AND CAUSING INTERMITTENT ILLUMINATION OF PYLON FLAP FAULT. REPLACED SENSOR PER SDR DLM90030389Sensor · intermittentAFTER T/O SLAT DISAGREE LIGHT REMAINED ON AFTER SLATS WERE RETRACTED. FOLLOWED POM PROCEDURE. FOUND LT WING SLAT SENSOR C D1-64 TO BE INTERMITTENT. REMOVED AND REPLACED SAME PER M/M. CYCLED FLAPS SEVERAL TIMES. ALL INDICATIONS NORMAL.SDR DLM90030374Battery Pack · dischargedFWD FLT ATTN STATION EMERGENCY FLASHLIGHT FAILS LED. REPLACED EMERGENCY FLASHLIGHT BATTERY PACK PER M/M CKS GOODSDR DLM90030351Line · leakingLT HYDRAULIC QUANITY FELL TO 6 QUARTS IN FLIGHT AT 33000 FT. TURNED OFF HYD PUMP PER ABNORMAL PROCEDURES CHECKLIST. RETURNED TO NORMAL LEVEL AFTER 10 MIN. FOUND GOUND SPOILER VALVE LINE LEAKING. INSTALLED APPROVED TEMP LINE PER M/M GOOD FOR 350 HRS FRSDR DLM90030294Engine · shutdownNUMBER 2 ENGINE SHUT DOWN ON DESCENT INTO DFW. FOUND NUMEROUS VSV AND ACC FAULTS. REPLACED ENGINE.SDR DLM90030245Relay · failedCREW REPORTS THAT AFTER BLOCK IN THE RAMP REPORTED HEAVY SMOKE/ELECTRIC ODOR EMINATING FROM THE APU. REPLACED STARTER AND START RELAY FOR SLOW SPOOL.SDR DLM90030236Door · openAIRCRAFT HAD AN AIR TURNBACK. UPON GEAR RETRACTION, NOSE GEAR MADE A LOUD NOISE AND CONTINUED TO SPIN. NO GEAR OR GEAR DOOR LIGHTS. GEAR ALSO VIBRATED. ONCE AT GATE MAINTENANCE FOUND THE LEFT NOSE GEAR DOOR OPEN. RESECURED NOSE GEAR DOOR.SDR DLM90030216Line · crackedRT SYS HYD PRESS DROPPED TO 0 PASSING APPROX 18K QTY ON RT SIDE WENT UP TO 27 QTS. RAN CHECKLIST. WHEN RT ENG PUMP WAS OFF WITH AUX PUMPS ON, PRESS ON RT SIDE WENT FROM 0 TO 700 PSI. THE LT PRESS WENT FROM 3000 TO 2800 PSI. AUX PUMPS AND RT ENG PUMPS NOW ISDR DLM90030205Uplock Target · out of adjustAFTER T/O, LT MLG RED WARNING LIGHT REMAINED ILLUMINATED AFTER RETRACTION. FOLLOWED POM PROCEDURES, LIGHT REMAIN ILLUMINATED. ADJUSTED LT GEAR UP AND LOCKED TARGET ON MLG DOOR, SWUNG GEAR. OPS CHECKS GOOD.SDR DLM90030219Tire · failedON LANDING BOTH LT MAIN TIRES BLEW. EMERGENCY VEHICLES CONFIRMED BLOWN TIRES AND SOME DAMAGE TO THE STRUT AND WING OCCURRED. TOUCHDOWN WAS VERY SMOOTH WITH CONTAMINATED RUNWAY AND MAX AUTOBRAKES SELECTED. BRAKES, DACMS, AND CONTROLLER CHANGED.SDR DLM90030174Valve · failedUNSAFT NOSE GEARUP. RECYCLED GEAR AS PER POM PROCEDURE. ON GEAR UP NOSE GEAR UNSAFE (RED) STAYED ON 35 SECONDS LONGER THAN OTHER GEAR LIGHTS AND THE AIRFLOW NOISE DURING THAT TIME WAS LOUD AND UNUSUAL. JACKED NOSE, RAN GEAR, OPS CHECK GOOD. CHECKED DOWN RISDR DLM90030150Transformer · failedWHILE RELOCATING THE A/C FROM THE PAD TO THE GATE, OPS REPORTED SMOKE/ODOR IN CABIN. DL MTC FOUND THE NR 1 T/R HAD FAILED AND SMOKED. INSULATION ABOVE THE T/R WAS BURNED. REPLACED T/R UNIT.SDR UIAFAA9201Scavenge Pump · brokenRT GEN OFF SHOW ON EOAP DURING THE FIGHT FROM MACAU TO SHANGHAI, AFTER LANDING LINE MAINTENANCE PERSONNEL REPORTED RT GEN BEARING FAIL WAS SHOWN ON EPCU AND HE CLAIMED THAT SERIOUS DAMAGE WAS FOUND ON VSCF GEN INCLUDING; EXTRUSION OF 3 ELECTRIC PLUGS BACKSHESDR DLM90050062Tire · failedUPON ARRIVAL INTO SLC TOWER INFORMED CAPTAIN THERE WAS SMOKE FROM NR 1 GEAR. FOUND NR 2 AND NR 3 TIRES BLOWN. LEFT AFT INBOARD FLAP DAMAGED. REPLACED NR 2 AND NR 3 MAIN WHEEL ASSEMBLIES. AFT FLAP REPAIRED. NO DAMAGE FOUND IN NR 1 ENGINE.SDR DLM90030046Sensor · failedAT CRUISE FL330 EOAP MESSAGE ELEVATOR SPLIT & PYLON FLAP FAULT ILLUMINATED. ALSO NO AUTOLAND ILLUMINATED ON FMA. RAN RTS ON DFGC 1 & 2. GO ON BOTH. RAN ACS TEST. NO FAULTS FOUND ELEVATOR POSITION SENSOR NR 2 ON DFGC 2. REPLACED RT ELEVATOR POSITION SENSOR ISDR DLM90030037Piston · failedNOSE GEAR UNSAFE ON TAKE OFF. COMPLIED WITH POM PROCEDURE CYCLED GEAR STILL UNSAFE UP. NOISE LEVEL WAS VERY HIGHT INDICATING DOOR AND OR GEAR WAS EXTENDED. ALSO AUTO SPOILER FAIL MSG. F/D WENT OF VIEW. STALL INDICATOR FAILURE. REPLACED NOSE LANDING GEAR SSDR DLM90021482Windshield · crackedRIGHT WINDSHIELD OUTER PANE CRACKED. REPLACED RT WINDSHIELD HEAT CONTROLLER AND WINDSHIELD.SDR DLM90021448Bottle · dischargedFIRST CLASS GALLEY SLIDE BOTTLE PRESS IS LOW. REPLACED GALLEY DOOR SLIDE PER M/M SYCLED DOOR ARM AND DISARM OK.SDR DLM90021403Attach Angle · crackedDURING HMV-1, THE FUSELAGE TO VERTICAL STABILIZER ATTACH ANGLE WAS FOUND CRACKED AT CANTED STA 1520.225 AND LONGERON L-2L. THE HORIZONTAL LEG WAS TRIMMED SIMILAR TO MD80 SRM 53-05-D, FIGURE 23. FILLER WAS ADDED TO THE TRIMMED OUT AREA AND A REPAIR ANGLE INSTALSDR DLM90021375Strut · wornA THRUST STRUT WAS FOUND TO HAVE EIGHT AREAS OF WEAR DAMAGE BEYOND CMM LIMITS. A DER PROVIDED A BLEND REPAIR. A DTA ASSESSMENT IS REQUIRED FOR CONTINUED SERVICE BEYOND THE TIME LIMITED REPAIR LIMIT.SDR DLM90021317Structure · bird strikeSUBJECT INBOARD LE SLAT WAS FOUND DAMAGED DUE TO BIRD STRIKE, REPAIR PER E/A 417937-14SDR DLM90021316Bearing · crackedHORIZONTAL STAB PIVOT BEARINGS CRACKED. FOUND DURING HORIZONTAL STAB PIVOT BEARING FREE PLAY. REPLACED.SDR DLM90021314Battery Pack · inoperativeFWD OVERHEAD EMERGENCY LIGHT INOPERATIVE. REPLACED BATTERY PACK AND CHARGER. FAILED DURING OPERATION TEST. NOW TESTS GOOD.SDR DLM90021309Skin · crackedDURING HMV-1, FOUND RAM AIR INLET CRACKED INLET ASSY WAS TOO EXTENSIVE. THEREFORE, A WELD REPAIR WAS DONE. REPAIRED PER ERA 378736+14SDR DLM90021159Wire · chafedTHE ORIGINAL WRITE UP HAPPENED IN ONTARIO. A/C NOW LOCATED MCI. DURING POWER TRANSFER FROM GROUND POWER TO SHIPS POWER SPARKS SEEN COMING FROM OVERHEAD BIN AT 12 C. AREA INSPECTED NO TROUBLE FOUND IN ONT. UPON ARRIVAL TO MCI PILOTS NOTICED C/B POPPED FOR PASSSDR DLM90021374Strut · wornA THRUST STRUT WAS FOUND TO HAVE WEAR DAMAGE BEYOND CMM LIMITS. A DER PROVIDED A BLEND REPAIR FOR THE ONE AREA OF DAMAGE. A DTA ASSESSMENT IS REQUIRED FOR CONTINUED SERVICE BEYOND THE TIME LIMITED REPAIR LIMIT.SDR DLM90021373Strut · wornA THRUST STRUT WAS FOUND TO HAVE THREE AREAS OF WEAR DAMAGE BEYOND CMM LIMITS. A DER APPROVED BLEND REPAIR WAS PROVIDED. A DTA ASSESSMENT IS REQUIRED FOR CONTINUED SERVICE BEYOND THE TIME LIMITED REPAIR LIMIT.SDR DLM90021372Strut · wornTHE THRUST STRUT WAS FOUND TO HAVE WEAR DAMAGE IN TWO PLACES ON THE STRUT BODY. A TIME LIMITED BLEND REPAIR WAS APPROVED BY A DER. A DTA ASSESSMENT IS REQUIRED TO AUTHORIZE CONTINUED SERVICE BEYOND THE TIME LIMITED REPAIR.SDR DLM90021076Proximity Sensor · inoperativeGEAR DOOR OPEN ANNUNCIATOR YELLOW WITH LANDING GEAR HANDLE UP AND LANDING GEAR LITES EXTINGUISHED. REPLACED RT GEAR DOOR PROX SENSOR. INDICATIONS CHECK NORMAL.SDR DLM90021067Actuator · failedVSV ACTUATOR HEAD END SEPERATED FROM BODY OF ACTUATOR RESULTING IN LARGE FUEL LEAK. FOUND AT GATE PRIOR TO FLIGHT AFTER ENGINE CHANGE.SDR UIA02007Wheel · departedNR 3 MAIN WHEEL MISSING , NO DAMAGE FOUND ON MLG OR FUSELAGE DURING TRANSIT CHECK. A/C APPROCHED AND LANDED WITH NORMAL CONFIGURATION, MAIN WHEEL FOUND ADJACENT TO TAXI WAY & "ANTI-SKID FAULT" MESSAGE SHOWED IAW PILOT REPORT. CARRIED OUT MAIN WHEEL CHECK IAW SDR DLM90020936Door Seal · dirty2L DOOR LEAK, CABIN ALTITUDE REACHED 10K FT. CHECKED 2L DOOR SEAL AND MATING SURFACE. NO DEFECTS NOTED. CLEANED 2L DOOR SEAL AND MATING SURFACE. PRESSURIZED ACFT TO 7 PSID. NO LEAKS/SQUEALS NOTED AT 2L.SDR DLM90020935Brake Assy · fireNR 2 BRAKE OVERHEAT ON ARRIVAL SOME FLAMES. COOLED BRAKES, NO FLAMES. REPLACED BRAKE ASSY AND NR 2 MAIN WHEEL ASSY. PERFORMED BRAKE TEMP SENSOR TEST, TESTS OK. NO LEAKS FOUND.SDR DLM90020907Screw · looseAIR TURNBACK, 2L DOOR HAD A LARGE AIRLEAK AUTO CONTROLLER DID NOT HAVE OUTFLOW VALVE FULL CLOSED. GOT CABIN ALT WARN LIGHT CABIN WAS AT 10000 FT/BIT AUTO CONTROLLER 1 FAULTED GROUND SWITCH. PRESSURIZED A/C PER M/M, NO DOOR LEAKS NOTED. FOUND LOOSE SCREW HADSDR DLM90020900Generator · lack of lubeRT AC POWER FAULT WITH R GEN OIL PRESS LIGHT DURING CLIMBOUT. FOUND RT GEN OIL LEVEL LOW. SERVICED SAME. RUN ENG PER PFHB AND NO LEAK. GEN OPS OK.SDR DLM90020837Engine · power lossLEFT ENGINE POWER ROLLED BACK AND EGT 625. CREW FOLLOWED POM AND SHUT ENGINE DOWN. REPLACED NR 1 ENG PER M/M.SDR DLM90020823Engine · overtempON CLIMBOUT EGT ROSE PAST RED LINE AFTER THROTTLE RETARDED TO DECREASE EGT. ENG AUTO SHUTDOWN. REPLACED ENG DUE TO EGT EXCEEDANCE.SDR DLM90020672Seal · looseLOUD VIBRATION PASSING THRU 10,000 FT ON CAPTAINS WINDOW SIDE. FOUND AERODYNAMIC SEAL LOOSE ON CAPTAINS WINDOW ON THE UPPERSIDE. REMOVED LOOSE SEAL. APPLIED NEW SEALER PER M/M.SDR DLM90020627Oven · dirtyFWD JUMPSEAT HALON EXTINGUISHER USED IN FWD GALLEY OVEN DUE TO A SMOLERING PIECE OF PAPER. CLEANED OVEN AND REPLACED HALON EXTINGUISHER.SDR DLM90020541Shear Tie · crackedFRAME CLIP FOUND CRACKED DURING HMV-1 AND WAS BEING REPLACED. BHEC INSPECT REVEALED A CRACK INDICATION.
Back to Boeing MD-90-30