Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS01836467Door Frame · crackedINSPECTION TYPE:C1 STA 1620 LT AFT ENTRY DOOR FRAME WEB IS CRACKED BELOW LOWER HINGE. REPAIRED WEB IAW SRM 53-2-0 FIG 1BSDR RRXA11331Frame · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO FRAME AT STA.55 AND L24L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 53-2-0 FIG.2.SDR RRXA11402Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON SEAT TRACK FS STA 600 LBL 48. REMOVED DAMAGED AREA, FABRICATED REPLACEMENT SECTION AND INSTALLED IAW 53-2-3 FIG 14 AND SRM 51-1-20DSDR UPS01836433Floorbeam · corrodedINSPECTION TYPE:C2 STA 1700 FLOORBEAM UPPER FLANGE IS CORRODED BEYOND LIMITS AT LBL 24. REPAIRED FLOORBEAM IAW 8110-3 APPROVED DH SK 807-264SDR DHL2001805015Computer · faultyIN CRUISE WITH AUTOPILOT IN AUX NAV INS NR 1, AIRCRAFT WOULD SUDDENLY ROLL RIGHT AND DIVERT FROM COURSE. OPS OK ON SYSTEM NR 2. PERFORMED SYSTEM TEST. NR 1 INS SHOWED CODE 4 DURING ALIGNMENT. REMOVED AND REPLACED NR 1 INU. PERFORMED ROLL CHANNEL CHECK; FASDR RRXA11400Fitting · crackedDURING A MAINTENANCE VISIT FOUND MAIN CARGO DOOR LATCH FITTING BACK-UP FITTING CRACKED BELOW CUSP ANGLE STA 140 AND CUSP JOINT TO LBL 48. *** CORRECTIVE ACTION *** REMOVED, FABRICATED, AND REPLACED FITTING IAW DWG 3772916 AND DC8 SRM 51-1-20D AND 53-1-0SDR UPS01836318Skin · crackedINSPECTION TYPE:C2 RIGHT WING LOWER SKIN IS CRACKED AT STRINGER 64 AT O/B END. REPAIRED SKIN IAW EO DC8-5730-9004 APPX E.SDR UPS01836264Intercostal · crackedINSPECTION TYPE:X2 FWD CARGO PIT AT FS 500 - 520 INTERCOSTAL AT LONG 33R IS CRACKED. REMOVED OLD INTERCOSTAL, FABBED NEW PART TREATED AND PRIMED NEW PART, DRILLED, INSTALLED NEW PART ALL IAW DC8 SRM 51-1-8 AND DAC DWG 5616 520 & SRM 51-1-20D.SDR RRXA11399Rib · crackedDURING A MAINTENANCE VISIT FOUND R/H O/B L/E UPPER RIB STA XFS 710 CRACKED. *** CORRECTIVE ACTION *** INSTALLED DOUBLER PER SRM 57-2-0SDR UPS01836496Skin · crackedINSPECTION TYPE:C1 STA 1723 LONG 15R FUSELAGE SKIN IS CRACKED. REPAIRED SKIN IAW SRM 53-2-1 FIG. 7SDR UPS01836374Skin · crackedINSPECTION TYPE:C2 RIGHT WING I/B LOWER SKIN IS CRACKED AT XFS 570. REPAIRED SKIN IAW EO DC8-5720-7767-A.SDR UPS01836346Web · corrodedINSPECTION TYPE:C2 MAIN CABIN CUSP MEMBRANE IS CORRODED BEYOND LIMITS AT STA 1580 LBL 48-50. REPAIRED WEB IAW SRM 53-2-0 FIG 23.SDR UPS01836320Fitting · crackedINSPECTION TYPE:C2 STA 1774 LONG 17L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4772397 AND SRM 53-1-0, 51-1-20D.SDR UPS01836317Fitting · crackedINSPECTION TYPE:C2 STA 1774 LONG 10L END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4772397 AND SRM 53-1-0, 51-1-20D.SDR UPS01836316Fitting · crackedINSPECTION TYPE:C2 STA 1772 LONG 10R END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4772397 AND SRM 53-1-0, 51-1-20D.SDR RRXA11398Pan · crackedDURING A MAINTENANCE VISIT FOUND LT HORIZ STAB O/B MOUNT PAN CRACKED AT STA XE195 REMOVED MOUNT PAN, REPAIRED AND INSTALLED IAW SRM 51-1-21, DWG 5652086-D, PS 10-301 AND SRM 51-3-0SDR RRXA11397Seat Track · corrodedDURING A MAINTENANCE VISIT FOUND CORREDED SEAT TRACK STA 1080 L13 - L48. *** CORRECTIVE ATION *** SPLICED SEAT TRACK STA 1060 - STA 1120 L13 - L48. INSTALLED REPLACEMENT PART IAW SRM 53-7-3 FIG 3D AND 53-2-3 FIG 14 AND 51-3-0.SDR RRXA11396Attach Fitting · crackedDURING A MAINTENANCE VISIT FOUND R/H SERVICE DOOR LWR HINGE ATTACH FITTING STA 159 CRACKED. *** CORRECTIVE ACTION *** REMOVED AND REPLACED FITTING IAW SRM 51-1-20DSDR RRXA11395Clip · crackedDURING A MAINTENANCE VISIT FOUND FRAME TO CUSP CLIPBROKEN STA 159 L21L INSIDE TORQUE BOX. *** CORRECTIVE ACTION *** REMOVED AND REPLACED CLIP IAW DC8 SRM 51-1-20D AND 51-1-8SDR RRXA11394Fitting · crackedDURING A MAINTENANCE VISIT FOUND C-PIT FITTING FWD OF STA 1160 AT L33R I/B IS CRACKED. *** CORRECTIVE ACTION *** REMOVED FITTING IAW DC-8 SRM 51-1-20D 751-1-21, FABRICATED REPLACEMENT FITTING IAW DC8 DWG 4758514. INSTALLED REPLACEMENT FITTING IAW DC8 SRM51-SDR RRXA11330Doubler · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LT WING L/E INTERNAL DOUBLER AT STA. XFS572.51, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 51-1-21, 51-1-20D.SDR RRXA11329Angle · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO C-PIT CROSS SLIDE FWD JAMB TRACK GUIDES AT STA. 1160 AND L33L-L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSSDR RRXA11393Frame · crackedDURING A MAINTENANCE VISIT FOUND FUSELAGE FRAME STA 55 CRACKED AT L24R. *** CORRECTIVE ACTION *** REPAIRED FRAME AT STA 55 BETWEEN L21R TO BETWEEN L26R AND L27R IAW SRM 53-3-3 FIG 3SDR RRXA11392Clamp · crackedDURING A MAINTENANCE VISIT FOUND R/H WING O/B L/E STA XRS 761 PNEUMATIC DUCT LOWER BRACKET CRACKED, FOUND 2 NUT PLATE BROKEN. *** CORRECTIVE ACTION *** REMOVED AND REPLACED NUT PLATES, REMOVED AND REPLACED BRACKETS IAW SRM 51-1-21 AND 51-30 AND 51-1-20D.SDR RRXA11391Fitting · misdrilledDURING A MAINTENANCE VISIT FOUND C-PIT FITTING FWD SIDE OF FRAME 1160 L35L IS MISDRILLED IN AFT UPPER RADIUS. REMOVED AND REPLACED FITTING IAW SRM 51-1-20DSDR RRXA11390Fitting · crackedDURING A MAINTENANCE VISIT FOUND C-PIT FITTING AFT SIDE OF STA 1260 L33R IS CRACKED. *** CORRECTIVE ACTION *** REMOVED AND REPLACED FITTING IAW SRM 51-1-20D AND 51-3-0SDR RRXA11328Skin · damagedDURING A MAINTANCE VISIT FOUND DAMAGE TO L/H WING T/E SKIN AT STA. XRS210, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DC-8 SRM 57-2-0 FIG2A.SDR RRXA11327Skin · crackedDURING A MAINTENANCE VISIT FOUND CRACK DAMAGE TO LOWER WING SKIN STRINGER 64L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DMSK606-470.SDR RRXA11326Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO D-PIT LOWER R/H FUSELAGE SKIN AT STA.1400 AND L34R-L33R, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED REPAIR AND INSTALLED IAW DHSK 606-616.SDR UPS01836345Doubler · corrodedINSPECTION TYPE:C2 RIGHT WING L/E LIFT TRANSDUCER DOUBLER IS CORRODED BEYOND LIMITS BETWEEN STA XFS 372.75 TO XFS 379.SDR UPS01836325Splice · crackedINSPECTION TYPE:C2 STA 1040-1060 LONG 31L SPLICE FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 3750257 AND SRM 51-1-20D.SDR UPS01836266Longeron · crackedINSPECTION TYPE:C2 AFT PIT FS 1270 LONGERON 35L CRACKED. REMOVED CRACKED SECTION OF LONGERON IAW DC8 SRM 51-1-20D, RECEIVED NEW SECTION, FAB'D P/N 3758593-1, LOCATED AND DRILLED HOLES IAW DC8 SRM 51-1-24, INSTALLED SECTION OF LONGERON IAW DC8 SRM 51-1-20D.SDR RRXA11401Fitting · crackedDURING A MAINTENANCE VISIT FOUND C-PIT AFT SIDE OF STA 1140 L35L FITTING CRACKED. *** CORRECTIVE ACTION *** REMOVED CRACKED FITTING PER SRM 51-1-20 AND INSTALLED NEW FITTING PER SRM 51-1-20 AT AFT SIDE OF STA 1140 L35LSDR RRXA11389Skin · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION ON LT HORIZ STAB L/E. REPAIRED PER DHSK 873-337 AT XFS 176.SDR RRXA11388Stiffener · crackedDURING A MAINTENANCE VISIT FOUND CRACKED STIFFENER AT IN R/H HORIZ STAB AT XFS 60. *** CORRECTIVE ACTION *** REMOVED, FABRICATED AND REPLACED CRACKED STIFFENER.SDR RRXA11387Doubler · crackedDURING A MAINTENANCE VISIT FOUND FUSELAGE EXT SKIN FWD UPPER CORNER OF R/H FWD SERVICE DOOR JAMB IS CRACKED 4 FASTENERS STA 160 L11R - L12R. *** CORRECTIVE ACTION *** REMOVED DAMAGED AREA, FABRICATED REPLACEMENT PART AND INSTALLED IAW 53-2-0 FIG 14.SDR RRXA11383Fitting · crackedDURING A MAINTENANCE VISIT FOUND R/H LWR CUSP TO FLOOR BEAM SUPPORT FITTING CRACKED AT STA 1220. *** CORRECTIVE ACTION *** REMOVED AND REPLACED FITTING IAW SRM 51-1-21 AND 51-1-21DSDR RRXA11382Doubler · crackedDURING A MAINTENANCE VISIT FOUND R/H WING UPPER CUTOUTS FOR #1 SPOILER MID HINGES ARE DISTORTED/BENT UPWARD. ***CORRECTIVE ACTION *** FABRICATED DOUBLERS INSTALLED DOUBLERS IAW SRM 57-2-0 FIG 2ASDR UPS01836349Fitting · crackedINSPECTION TYPE:C2 STA 1772 LONG 17R END FITTING IS CRACKED. REMOVED AND REPLACED FITTING IAW DWG 4772397 AND SRM 53-1-0, 51-1-20D, 51-1-21.SDR UPS01836339Seat Track · corrodedINSPECTION TYPE:C2 STA 1100 TO 1120 RBL 24 SEAT TRACK IS CORRODED BEYOND LIMITS. REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 8A.SDR UPS01836338Seat Track · corrodedINSPECTION TYPE:C2 STA 1100-1120 LBL 46 SEAT TRACK IS CORRODED BEYOND LIMITS. REPAIRED SEAT TRACK IAW SRM 53-2-3 FIG 8A.SDR UPS01836265Fitting · crackedINSPECTION TYPE:X2 AFT PIT FS 1152 FITTING AT L31R-L33R IS CRACKED. REMOVED BANANA FITTINGS AT STA 1152 & 1160 IAW DC8 SRM 51-1-20D, REC' D LOCATED AND DRILLED NEW FITTING AT STA 1152 IAW DC8 SRM 51-1-24 AND REINSTALLED NEW FITTING IAW DC8 SRM 51-1-20D.SDR UPS01836243Fitting · crackedINSPECTION TYPE:C2 AFT PIT STA 1230 INSIDE TORQUE BOX AT L32R FITTING CRACK. REMOVED AND REPLACED (2) BANANA FITTING (4) EACH LONGERON END FITTINGS AND SUPPORT ANGLE AT RT JAMB AREA IAW DC8 SRM 51-1-20D.SDR UPS01836242Fitting · corrodedINSPECTION TYPE:C2 AFT PIT FS 1220 - 1228 FITTING AT L31R HAS EXFOLIATED CORROSION. REMOVED AND REPLACED NEW FITTING IAW DC8 SRM 51-3-0 & 51-1-20D.SDR DHL2001804012Proximity SwitchDURING TAKEOFF TAKEOFF WARNING HORN WENT OFFREMOVED AND REPLACED LANDING GEAR PROX BOX IAW MM 27-52-1, 27-52*-2 OPS CK GOODSDR RRXA11386Splice · crackedDURING A MAINTENANCE VISIT FOUND D PIT L36 SPLICE FITTING CRACKED STA 1340. *** CORRECTIVE ACTION *** REMOVED AND REPLACED CRACKED FITTING IAW SRM 51-1-20D AND 51-1-11.SDR RRXA11381Fitting · corrodedDURING A MAINTENANCE VISIT FOUND CORRODED BATH TUB FITTING AT STA 1220 L33R - L34R. *** CORRECTIVE ACTION *** REMOVED AND REPLACED CORRODED BATH TUB FITTING AT STA 1220 L33R - L34R IAW SRM 51-1-20SDR RRXA11380Fitting · crackedDURING A MAINTENANCE VISIT FOUND FITTING CRACKED IN CPIT FWD TORQUE BOX STA 1172 L33R. *** CORRECTIVE ACTION *** REMOVED AND REPLACED PER SRM 51-1-20DSDR RRXA11324Longeron · corrodedDURING A MAINTENANCE VISIT FOUND CORROSION DAMAGE TO LONGERON AT STA.320 AND L29L, DAMAGE EXCEEDED LIMITATIONS IAW DC-8 SRM. /////CORRECTIVE ACTION///// REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED PART AND INSTALLED IAW DC-8 SRM 53-2-2 FIG10 ASDR UPS01836337Attach Fitting · corrodedINSPECTION TYPE:C2 STA 35 FRAME ATTACH FITTING IS CORRODED BEYOND LIMITS AT LONG 21R. REMOVED AND REPLACED FITTING IAW DWG 4597643 AND SRM 53-1-0, 51-1-21, 51-3-0.
Back to Douglas DC-8-73F