SDR WRLA200207Gps · failedAIRCRAFT RETURNED TO FRANKFORT DUE TO GPS NAVIGATIONAL ERROR. RESET GPS (ALL THREE UNITS) BY SWAPPING NAVIGATIONAL DATA, TO EXPIRED DATA BASE AND BACK TO ACTUAL NAVIGATIONAL DATA BASE. ALL FUNCTIONS BACK TO NORMAL. DATA BASE RELOADED. (M)SDR 0200911211Stringer · crackedDuring "H" check found cracks on LH horizontal stabilizer outboard aft skin panel integral stringers, #1-7.5 inch crack at stations XE 77.100 and stringer #4-6.25 inch crack at station EX 77.100. Repaired per EA 12-162218.SDR CNMA200200002Power Supply · dischargedEMERGENCY EXIT LIGHT AT R4 DOOR CAME ON AFTER LANDING REMOVED AND REPLACED EMENGENCY LIGHT POWER SUPPLY OPS CHECKED PER DC-10 MM 33-51SDR 02FDEA00135Anti-Ice Valve · faultyNR 1 ENGINE ANTI-ICE DISAGREE LIGHT ILLUM AFTER ANTI-ICE WAS ON. REMOVED AND REPLACED NOSE COWL A/I VALVE PER MM 30-20-00.SDR 0200471235Thrust Reverser · malfunctionedDURING CLIMB, THE NR 1 THRUST REVERSER INTRANSIT LIGHT ILLUMINATED FOLLOWED BY A SEVERE AIRCRAFT YAW. THE CREW FOLLOWED COM PROCEDURE AND SHUT DOWN THE NR 1 ENGINE. FUEL WAS DUMPED AND THE AIRCRAFT RETURNED TO IAD LANDING WITHOUT INCIDENT. MAINTENANCE PLACESDR WRLA200204Duct · rupturedEMERGENCY LANDING DUE TO MODERATE CABIN SMOKE/CARGO DECK. REMOVED AND REPLACED AFT LEFT SIDE DUCT ASSEMBLY, P/N AAM7241-1, DUCT ASSY AFT WELDED. REMOVED AND REPLACED AFT LEFT SIDE DUCT ASSY AFT WELDED. LEFT SIDE AFT FUSELAGE PNEUMATIC DUCT ASSY. (M)SDR 02FDEA00144Drive Shaft · shearedCTR CARGO DOOR LIFT ACTUATOR OUTPUT DRIVE SHAFT SHEARED, CAUSING DOOR TO FREE FALL AND IMPACT MAINTENANCE STAND. REMOVED AND REPLACED ACTUATOR CTR CARGO COMPARTMENT PER MM 52-32-01 & 52-32-07.SDR 02FDEA00094Drive Shaft · shearedCENTER CARGO DOOR LIFT ACT OUTPUT DRIVE SHAFT SHEARED, CAUSING DOOR TO FREE FALL AND IMPACT MAINTENANCE STAND.SDR WRLA200201Blade · vibrationNR 1 ENGINE VIBRATION 80-95, ALL OTHER INDICATIONS NORMAL. EVENT OCCURRED AT THE TOP OF THE CLIMB SEGMENT WHEN THE FLIGHT AS THE CREW WAS LEVELING THE AIRCRAFT. THE CAPTAIN ELECTED TO RETURN TO MIA. LUBED FAN BLADES, PERFORMED MAX POWER RUN AT 80-95 PERCENTSDR CNMA200200001Regulator Valve · inoperative#3 PNEUMATIC SUPPLY PRESSURE READS ZERO WITH SUPPLY SELECTOR IN ANY MODE. COM PROCEDURES ACCOMPLISHED ON CLIMBOUT. #2 PNEUMATIC SUPPLY HI TEMP ILLUMINATED. TEMP GUAGE INDICATED RE LINE.SDR CNMA200100037Battery PackEMERG. LITES WILL NOT GIVE GREE LITE DURING TEST-ALL LIGHTS OPERATEFOUND MID CABIN EMERG LITES POWER SUPPLY INOP R/R MIDCABIN PWR SUPPLY OPS CKD NORMALLY PER M/M 33-51SDR CNMA200100038Skin · corrodedFOUND CORROSION ON UPPER LEFT WING SURFACE (LEVEL 2) IN EXCESS OF SRM ALLOWABLE LIMITS IN FOUR (4) LOCATIONS. BOEING CONTACTED AND BLEND OUT ACCOMPLISHED IAW BOEING INSTRUCTION, 8110-3 ISSUED AS PERMANENT REPAIR.SDR 0104671225GeneratorDURING CRUISE ENROUTE TO HNL, THE NBR 1 GENERATOR DROPPED OFF LINE. FLIGHT CREW FOLLOWED COM PROCEDURE AND DISCONNECTED CSD AND GENERATOR. FLIGHT CONTINUED TO HNL AND LANDED WITHOUT INCIDENT. MAINTENANCE FOUND NBR 1 GENERATOR FAILURE RESULTED IN STRUCTURAL SDR CNMA200100036Indicator · malfunctionedENGINE FIRE INDICATION ON T/O CLIMBOUT AT APPROX 400 FT AGL ON NR 3 ENGINE. ENGINE FIRE SEVER DAMAGE CHECKLIST PERFORMED. FIRE INDICATION WENT OUT. DUMPED APPROX 29,000 LBS FUEL AND RETURNED TO LICZ. ON ENGINE FIRE SEVER DAMAGE PROCEDURES, WHEN AGENT NR 1 SDR 0104661227Actuator · malfunctionedAFTER TAKEOFF, GEAR HANDLE COULD NOT BE MOVED TO RETRACT POSITION. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE BLED TRIM ACTUATOR AND TRIM POSITION CYLINDER. OPERATIONAL CHECK OK.SDR CNMA200100035Duct · blownENGINE FIRE INDICATION ON TAKEOFF CLIMBOUT 2 APPROX 400 FT AGL ON NR 3 ENGINE. COMMENCE ENG FIRE SEVERE DAMAGE CHECKLIST PERFORMED. FIRE INDICATION WENT OUT. DUMPED APPROX 29,000 LBS FUEL AND RETURNED TO LICZ. FOUND 14TH STAGE BLEED DUCT BLOWN.SDR 01FDEA00895Guide · corrodedN 56 LEVEL CORROSION IN FWD CARGO PIT ON LEFT HAND CARGO GUIDE RAIL.SDR 01FDEA01114Proximity Switch · faultyAFTER LANDING GEAR HANDLE LOWERED HAD NORM GEAR EXT NOISES. REMOVED AND REPLACED PROX SWITCH ELECTRONIC UNIT PER MM 32-61-01-2.SDR HALA0100248Rccb · failedLAX - FLT 32 - AIR DIVERSION AT 3 HOURS INTO FLIGHT, LT EMERGENCY AC BUS OFF LIGHT ILLUMINATED, RESTORED SYSTEM. FOLLOWED CHECKLIST, 5 MINUTES LATER PROBLEM REOCCURRED. NR 1 GALLEY POWER OFF LIGHT ILLUMINATED. COULD NOT RESTORE POWER BY RESETTING, REMAINED SDR CALA0100926Warning System · malfunctionedA FORWARD CARGO FIRE WARNING WAS INDICATED AT 10,000 FEET ON APPROACH TO HNL. BOTH FIRE BOTTLES WERE DISCHARGED AND THE AIRCRAFT LANDED AT HNL WITHOUT INCIDENT. MAINTENANCE FOUND NO EVIDENCE OF FIRE. THE FIRE WARNING SYSTEM WAS TROUBLESHOT AND NO FAULTS WERE FSDR WRLA200117Adc · faultyABORTED TAKEOFF AT 80 KNOTS CALLED BY FIRST OFFICER DUE TO 25 KNOTS AIRSPEED DISCREPANCY BETWEEN FIRST OFFICER AND CAPTAINS AIRSPEED INDICATORS. TAXI BACK TO GATE FIRST OFFICER AIRSPEED INDICATOR READS 70 KNOTS. REMOVED AND REPLACED NR 2 AIR DATA COMPUTER (CSDR CALA0100826Restrictor Valve · failedTHE LT MLG WOULD NOT RETRACT AFTER TAKEOFF FROM NRT. A VISUAL CHECK CONFIRMED THE GEAR WAS DOWN. THE AIRCRAFT WAS RETURNED TO NRT WHERE IT LANDED WITHOUT INCIDENT. THE LT MLG RETRACT CYLINDER WAS REMOVED AND REPLACED, BUT THE PROBLEM REMAINED. MAINTENANCE SDR 0103151225Torque Link · disconnectedABORTED TAKEOFF AT 100 KNOTS DUE TO VIBRATION AND LOSS OF NOSE GEAR STEERING. FOUND NOSE LANDING GEAR TORQUE LINKS DISCONNECTED. AIRCRAFT WAS TOWED TO THE GATE. FOUND CEILING PANELS DOWN, CENTER OVERHEAD BIN DAMAGED, AND E/E SHELVING DAMAGED. AFTER INSPECTSDR CNMA200100032Connector · looseEMERGENCY AISLE LIGHTS ILLUMINATED FROM ROW 35 AFT. RESET BATTERY CONNECTORS, OPS CHECKED OK.SDR CALA0100815Skin · crackedINSPECTION FOUND A 1" CRACK IN FORWARD CARGO DOOR SKIN(DOUBLER) ON LATCH ACCESSORY DOOR CUTOUT AREA. THE CRACKED AREA WAS CUT OUT AND A REPAIR DOUBLER WAS INSTALLED IAW SRM 52-00-01, FIGURE 9.SDR CALA0100814Seat Track · corrodedINSPECTION FOUND MAIN DECK SEAT TRACK CORRODED AT Y = 1860, X = -60.00, JUST AFT OF R-4 ATTENDANT SEAT. THE CORRODED SECTION OF SEAT TRACK WAS CUT OUT AND A NEW SECTION OF SEAT TRACK WAS INSTALLED USING SPLICE HAT AND SPLICE PLATE IAW SRM 53-70-00, FIGURE 1.SDR CALA0100808Seat Track · corrodedINSPECTION FOUND MAIN DECK SEAT TRACK CORRODED AT X = 107.25 AND Y = 800-824. THE CORRODED SECTION OF SEAT TRACK WAS REMOVED AND A NEW SEAT TRACK SECTION WAS SPLICED IN IAW SRM 53-70-00, FIGURE 1.SDR CALA0100806Fuse · blownINSPECTION FOUND L-4 AND R-4 DOOR LOWER EXIT LIGHT INOPERATIVE. THE FUSE IN EMERGENCY LIGHT BATTERY PACK U1-165 WAS REMOVED AND REPLACED IAW WDM 33-52-04 AND OPERATION CHECKED GOOD.SDR 0102941228Bolt · backed outON WALKAROUND, FOUND LEFT MAIN LANDING GEAR DOOR EXTENDED. SUBSEQUENT INSPECTION FOUND SUPPORT BOLT IN MAIN LANDING GEAR SIDE BRACE ATTACH FITTING BACKING OUT. REMOVED, INSPECTED, AND REINSTALLED SIDE BRACE ATTACH FITTING WITH NEW BOLTS AND BARREL NUTS. OPESDR CALA0100762Spar · crackedINSPECTION FOUND A 2 INCH CRACK IN NR 3 PYLON LOWER SPAR WEB AT FAN DUCT CUTOUT. A REPAIR ANGLE AND STIFFENER WERE INSTALLED IAW SRM 54-20-00, FIGURE 19A.SDR CNMA200100031Battery Pack · malfunctionedB-ZONE FLOOR TRACK LIGHTING CAME ON AFTER T/O, WOULD NOT RESET. RESET FLOOR TRACK BATTERY PACK, SYS OPS CHECK NORMAL ON GROUND.SDR CNMA200100030Battery Pack · malfunctionedTHE 4L TRACK LIGHTING CAME ON LANDING. RESET BATTERY PACK, OPS CHECKED GOOD.SDR 01FDEA00662Radar · faultyREPEAT WRITE UP NR 1 RADAR SYS UNSATISFACTORY WITH HEAVY SIDE RETURNS.SDR 01FDEA00661Antenna · malfunctionedREPEAT WRITE UP WX RADAR RETURNS BOTH SYS SHOW BLANK AREA IN A SPOKE PATTERN. REMOVED AND REPLACED ANTENNA PER IAW MD DC10-30 AMM 34-41-01-2.SDR 01FDEA00663Radar · malfunctionedAFT 38 MIN RADAR STARTED SPOKING. REMOVED AND REPLACED RADOME MM 53-51-00-2. REMOVED AND REPLACED WX RADAR ANTENNA PEDESTAL MM 34-41-01-2.SDR CNMA200100028Wire · brokenNR 2 ENG OIL TEMP HIGH AFTER TAKEOFF, ENG SHUTDOWN. REPAIRED BROKEN WIRE AT ADEL CLAMP ON ENG IAW 20-30-01. ENGINE GROUND RUN, OPS CHECKED OK.SDR 01FDEA00629Radar · malfunctionedRADAR SPOKING BOTH SYSTEMS ALL RANGES ALL GAINS SETTINGS REPEAT WRITEUP.SDR 01FDEA00628Antenna · malfunctionedBOTH CAPT AND F/O RADAR DISPLAY BEGAN TO SPOKE. REMOVED AND REPLACED WEATHER RADAR ANTENNA AND PLATE AS PER MM 34-41-01-2. GROUND CHECK OK.SDR CNMA200100027Light · malfunctionedFLOOR EMERGENCY ESCAPE LIGHTING ILLUMINATED IN MID SERVICE ON LT FWD SIDE OF ZONE B. RESET POWER TRANSFER, OPS CHECKED SEVERAL TIMES SATISFACTORY.SDR 0102611230Control Panel · failedDURING CRUISE, FLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR AT SEAT 3A. TURNED OFF RECIRCULATION FAN AND READING LIGHT AND CONTINUED TO DTW. LANDED WITHOUT INCIDENT. REPLACED THE OVERHEAD DECODER. OPERATIONAL CHECK GOOD.SDR HALA0100150Fitting · leakingLAX - FLT 32 - NR 1 SYSTEM HYDRAULIC FAILURE. DIVERTED TO LAX, WHERE AN UNEVENTFUL LANDING WAS MADE. FOUND NR 1 SYSTEM HYDRAULIC LINE AT THE UNION TO THE STAB TRIM BRAKE LEAKING. ALSO, PRECAUTIONARY CHECKED ENGINE DRIVEN HYDRAULIC MODULE AND SYSTEM RETURN FSDR 01FDEA00450Hydraulic Line · damagedNR 3 HYD QTY LEAK TO A QTY OF .2 GAL CAUSING LVL ALERT OF HYD 3 FAIL. ACCOMPLISH RED TABS INCLUDING ALT GEAR EXT. REMOVED AND REPLACED DAMAGED SECTION OF HYD LINE AND INSTALL NEW PIECE OF TUBING AND SWAGGED PER MM 20-10-01-2. LEAK CK GOOD. REINSTALLED PANESDR 01FDEA00417Floor Support · corrodedBS 1984 X=2R, Z=-19 LWR SIDE OF FLOOR SUPPORT HAS LEVEL (2) CORROSION APPROX 3.0 LONG X 2.0 WIDE AROUND MISSING NUT PLATE.SDR 01FDEA00400Stanchion · corrodedAFT FUS WASTE COMP, FS 1967, AT X=23, X=0, X=23 3 EA STANCHIONS THAT RUN VERTICALLY FROM FLOORBOARD LEVEL TO COMP FLOOR HAVE LEVEL 2 EXFOLIATION CORROSION AROUND NUT PLATES.SDR CNMA200100024Battery Pack · dischargedL4 DOOR EMERGENCY TRACK LIGHTING ILLUMINATES INTERMITTENTLY. REPLACED BATTERY PACK. SYSTEM OPERATION CHECKS GOOD IAW MM 33-50.SDR 0102401230Flap · corrodedIn L check, found corrosion inside LH OB flap leading edge at hinge attachment area. Repaired per EA12-162200.SDR CALA0100470Floor Support · crackedINSPECTION FOUND A 6 INCH CRACK IN CENTER CARGO FLOOR SUPPORT FLANGE AT STA 1601, X = 18R. THE FLOOR SUPPORT WAS REMOVED AND A NEW SUPPORT WAS INSTALLED IAW SRM 53-30-1 AND GMM 10-900-01.SDR CALA0100469Seat Track · corrodedINSPECTION FOUND SEAT TRACK CORRODED AT STA Y = 2000-2007, X = 90L. THE SEAT TRACK WAS REPAIRED IAW SRM 53-70-00, FIGURE 5 AND ECRA 5100-01844.SDR CALA0100466Skin · crackedINSPECTION FOUND A CRACK IN RT WING LEADING EDGE SKIN AT SLAT NR 7 I/B TRACK, XORS 79.9. REPAIRED IAW SRM 57-10-00.SDR CALA0100465Shear Tie · corrodedINSPECTION FOUND SHEAR CLEAT IN CENTER CARGO BILGE CORRODED AT STA 1801 BETWEEN LONGERON 49L AND 49R. THE SHEAR CLEAT WAS REMOVED AND A NEW SHEAR CLEAT WAS INSTALLED IAW SRM 51-30-01 AND GMM 10-900-01.
Back to Mcdonnell-Douglas DC-10-30