SDR DALA1129579871Frame · crackedMAIN CABIN RT STA 734 MAIN FRAME CRACKED APPROX 2.5 INCHES. R & R MAIN FRAME, MAIN CABIN RT STA 734 L0R-L18R IAW SRM 51-10-4, 51-30-2, 51-30-5 & 51-30-8. NEW FRAME PN 9923406-502N 26 APR11 P-138 REQUIRED INSP.SDR DALA1135329866Seat Track · damagedMAIN CABIN-AFTER REMOVAL OF SEAT TRACK ON FOUND PREVIOUSLY DOUBLE DRILLED HOLES IN CUSP WEB AT RBL 44 BETWEEN STA 218 AND 237. GAINED ACCESS, REMOVED DAMAGE WEB, MATERIAL PER DWG SG09530019 LOCATED, DRILLED, DEBURRED, ALODINED AND PRIMED ALL REPAIR PARTS PER SDR DALA1132079866Cusp Web · crackedMAIN CABIN BETWEEN STA 1116 AND 1136 RT CUSP WEB CRACKED AT LIGHTING HOLE. REMOVED FLOOR SUPPORT, RCVD MAT.025 7075-T6, FABRICATED, LOCATED, DRILLED, DEBURRED, TREATED AND PRIMED AND INSTALLED NEW DOUBLER AND FLOOR SUPPORT IAW DC9 SRM 51-10-4, 51-10-3, 51-30-SDR DALA1132029866Cusp Web · crackedMAIN CABIN BETWEEN STA 870 AND 889 RT CUSP WEB CRACKED SEVERAL PLACES. REMOVED DAMAGE 1 INCH BY 1 INCH STA 893. RCVD MAT (.025) 7075-T6 LOT NR 1120665. REMOVED DAMAGE 10 INCH BY 5 INCH STA 875-883. FAB, LOC, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLEDSDR DALA1131999866Longeron · crackedMAIN CABIN STA 522 RIGHT LONG 17 CRACKED. REMOVED SECTION OF L17R FROM STA 473-564 IAW DC9 SRM 53-02 FIG 18. RECEIVED NEW LONG AND SPLICE IAW DC9 SRM 53-13-2. NDT VERIFIED NO CRACKS EXIST IAW DC9 NDT SPM 06-10-01.001. INSTALLED SPLICE AND NEW SECTION OF LOSDR DALA1130269866Floorbeam · corrodedMAIN CABIN OVERWING STA 734 BETWEEN RBL-20 AND RBL-44 FLOOR SUPPORT HAS CORROSION. REMOVED, FOUND TO BE CRACKED .3750 INCH LONG, OBTAINED MATERIAL, (.050-2024T3), FORMED, NEW SUPPORT,DRILLED, DEBURRED, TREATED, PRIMED, SEALED, INSTALLED IAW SRMS (51-30-2) (53SDR DALA1129029871Keelbeam · damagedKEEL BEAM AREA BETWEEN GEAR DOORS THRU ACCESS 5501 UPPER LT ANGLE CRACKED APPROX 2 INCHES. CUT AND REMOVED DAMAGED SECTION OF ANGLE. NDT IAW NDT SPM 06-10-01, A2700 CHECKED GOOD. FAB (1) REPAIR SECTION 7075 0 .063. HEAT TREAT TO T6 ACCOMP ON TRAVELER NSDR DALA1129019871Support Angle · crackedAFT ACCESSORY STA 1258, RT FAN INBD VERTICAL SUPPORT ANGLE CRACKED AT BOTTOM FASTENER. FABRICATED REPAIR DOUBLERS RT FAN INBD VERTICAL SUPPORT ANGLE AFT ACCY STA 1258 IAW SRM 51-10-4, 51-10-2 & 53-01, FIG 2. .025 2024-T3 IAW DWG 9911840. TREATED AND PRIMED SDR DALA1129009875Skin · dentedLWR FUSELAGE BS Y1134,BETWEEN LONGS. 24 RT AND 25 RT EXT SKIN WITH DENT. DAMAGE AT STA 1134, BETWEEN L24R TO L25R, L=1.5",D=0.025", & 0.2 FROM L24R, FOUND OUT OF LIMITS IAW SRM 53-04, FIG 38, SHEET 2, TABLE C, CONDITION 1B. REFORMED DENT TO ORIGINAL CONTOUR ISDR DALA1128999875Floor Support · corrodedCABIN FLOOR SUPPORT ANGLE, RBL-44, STA 160 TO 200 HAS CORROSION. REMOVED CORROSION FLOOR SUPPORT ANGLE RBL 44, STA 160-200 IAW SRM 51-10-3 MEASURED MATERIAL ORIGINAL THICKNESS FOUND MATERIAL LOSS. OUT OF LIMITS IAW SRM 53-01, FIG 1 FABED FLOOR SUPPORT ANGLE SDR DALA1128989875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL NR 21-50 HAS CORROSION. REMOVED CORROSION IAW 51-10-3 FOUND TO BE OUT OF LIMITS IAW 57-01. FABED FLOOR PNL 21-50 IAW SRM 53-01. FABRICATED FLOOR PNL 21-50 IAW SRM 53-23-0 TREATED AND PRIMED IAW SRM 51-10-3. REASSEMBLED FLOOR PANSDR DALA1128979875Floorbeam · corrodedCABIN FLOOR SUPPORT ANGLE, STA 200 BETWEEN BL-0 AND RBL-22 HAS CORROSION. REMOVED CORR FLOOR SUPPORT ANGLE STA 200 BETWEEN BL-0 TO RBL-22 IAW SRM 51-10-3 PG46, PARA 26, MATERIAL ORIGINAL THICKNESS .063, MATERIAL LOSS .024 FOUND MATERIAL OUT OF LIMITS IAW SRM SDR DALA1128969875Floor Support · crackedCABIN FLOOR SUPPORT COMPOSITE HAT CHANNEL CRACKED AND NUT PLATES CORRODED, RBL 53, BETWEEN STA 168-200. REMOVED 7 EA NUT PLATES TO FOM COMPOSITE REPAIR IAW SRM 51-30-2, FIG 19. REMOVED DAMAGE IAW ER/A 491541-14 AND SRM 51-70-1, PAR 3A, PG:4. APPLIED REPAIR SSDR DALA1128959875Floor Support · corrodedCABIN FLOOR SUPPORT ANGLE, STA 200 BETWEEN RBL-44 HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3, PG:46, PAR 26. MATERIAL ORIGINAL THICKNESS .06 3 MATERIAL LOSS .024 FOUND OUT OF LIMITS IAW SRM 53-01, FIG 1 FABRICATED SUPPORT ANGLE WITH EXTRUSION PN 00-0SDR DALA1128949875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL NR 20-50 HAS CORROSION. REMOVED CORROSION AREAS ON CABIN FLOOR PANEL IAW SRM 51-10-3. MATERIAL ORIGINAL .025" IAW SRM 53-23-0, ITEM 18. MATERIAL LOSS .010" OUT LIMITS IAW SRM 53-01, PG 8, FIG 1. FABED PANEL .025" 2024T3 BATCH 0SDR DALA1128939871Cusp Web · corrodedMAIN CABIN RT CUSP WEB BETWEEN STA 370 AND 389 HAS CORROSION. CPCP TASK 58-53309 GAINED ACCESS. R & R RT CUSP WEB STA 370-389 FROM .032 7075T6. RESTORED AREA IAW SRM 51-30-1, 51-30-5, 51-30-2, 51-30-3, DWG SG09530019.P-125. REQUIRED INSP COMPLETED.SDR DALA1128929875Floor Panel · corrodedPASSENGER CABIN FLOOR PANEL NR74-50 EDGE IS DAMAGED AND HAS CORROSION. REMOVED 2EA HAT CHANNELS FROM FLOOR WEB PANEL IAW SRM 51-30-2, FIGURE 20, FABED NEW WEB PANEL REF SRM 53-23-0, PAGE 8, FIG 5,TREATED AND PRIMED IAW SRM 51-10-3, PAGE 41, SRM 51-10-3 PAGE 3SDR DALA1128899871Frame · chafedAFT ACCESSORY STA 1209, LT LONG 4 VALVE CHAFING INTO PREVIOUS REPAIR ON WEB. REMOVED EXISTING REPAIR IAW SRM51-30-2. FABRICATED NEW DOUBLER .032 7075-T6 IAW SRM 53-01, FIG 4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED DOUBLER IAW SRM 53-01, FIG 4, 51-30-SDR DALA1128889875Skin · dentedPASSENGER AFT ENTRANCE DOOR STAIRWAY EXTERNAL SKIN WITH DENTAT STA YSD33 X 2.5. MEASURED DENT AND FOUND TO BE OUT OF LIMITS IAW SRM 53-04 CUTOUT DENTED AREA IAW SRM 52-05, FIG 3, PG 8. FABRICATED TREATED PRIMED AND INSTALLED REPAIR DOUBLER FILLER AND TAPERESDR DALA1128819871Fitting · corrodedMAIN CABIN BETWEEN STA 693 AND 712 RT LONG 19 BATH TUB FITTING HAS CORROSION. CORROSION FOUND OUT OF LIMITS IAW SRM 53-01. REMOVED OLD FITTING, LOCATED, DRILLED & INSTALLED NEW FITTING PN 5913055-508 IAW SRM 51-10-5, 51-70-2 & ERA 490847-14 P-205, REQUIRED INSDR DALA1128799871Doubler · dentedDENT IN UPPER WINDOW BELT DOUBLER, STA 712, LT SIDE. DENT MEASURES .017" X 7" DX=41 TOOL H9340. DENT FOUND TO BE OUT OF LIMITS IAW SRM 53-04, FIG 38. R & R WINDOW BELT AT STA 712, PN 9-5300-3-1772, PO 1098W037 IAW SRM 51-30-2 & 51-30-1, 51-30-5.SDR DALA1128779866Floorbeam · corrodedMAIN CABIN, STA 237, LBL 1 TO LBL 20 FLOORBEAM HAS CORROSION. FLOORBEAM FOUND TO BE OUT OF LIMITS DUE TO EXFOLIATION IAW SRM 51-10-3. REMOVED SUPPORT IAW SRM 51-30-2. FABRICATED LOCATED,DRILLED DEBURRED IAW SRM 51-10-4. TREATED & PRIMED IAW SRM 51-10-3. SDR DALA1128759866Floor Support · corrodedMAIN CABIN STA 200 TO 237 BL 0 FLOOR SUPPORT HAS CORROSION. MAIN CABIN FLOOR SUPPORT STA 200-237 BL 0.FOUND OUT OF LIMITS IAW SRM FIG ` SHEET 3.MORE THAN 50% MATERIAL LOSS NOTED. FABRICATED AND REPLACED FLOOR SUPPORT IAW SRM 53-13-3,51-10-1 FIG 22 AND SRM 51-3SDR DALA1128729871Door Frame · corrodedE & E COMPARTMENT AFT LOWER END OF AIRSTAIR DOOR CUTOUT HAS CORROSION. CORR ON CORNER ANGLE FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG.1 75% MAT LOSS.CUT ACCESS HOLE STA 207 IN WEB TO GAIN ACCESS TO ANGLE FASTENERS 5"X 5" AREA IAW SRM 51-70-4 DEBURRED AND ISDR DALA1128709871Frame · chafedFS 1190 AT L16R FRAME HAS HOLE CHAFED THRU BY ORIGINAL AUG VALVE. CUT OUT DAMAGED AREA 1 1/2"X 3/4" IAW SRM 53-03 FIG4. NDT VERIFIED DAMAGE REMOVED. NO CRACKS IAW NDT SPM 06-10-01.001 REC REPAIR ANGLE. LOCATED, DRILLED IAW SRM 51-10-4. FABRICATED DOUBLER PLSDR DALA1128699871Frame · corrodedE & 3 COMP AIRSTAIR DOOR LOWER INTERIOR FRAME HAS 2EA SPOTS OF CORROSION. RECEIVED AND REPLACED WITH SERVICEABLE DOOR PER SRM 51-30-1.SDR DALA1130569866Intercostal · damagedMAIN PAX CABIN-UPON REMOVAL OF FLOOR SUPPORT FOUND INTERCOSTAL BETWEEN STA 237 & 256 HAS EXISTING DOUBLER DRILLED HOLES. REMOVED AND REPLACED INTERCOSTAL P/N 3913576U501 IAW DC9 SRM 51-10-4, 51-30-5 AND 53-13-2.SDR DALA1132799852Power Supply · inoperativeTHE TAIL CONE AND VENTRAL STAIR EMERGENCY LIGHTS WERE INOP. LINE MAINTENANCE REPLACED THE POWER PACK PER THE AMM. OPERATIONAL CHECK WAS SUCCESSFUL. AIRCRAFT IS GOOD FOR SERVICE.SDR DALA1131319866Support Fitting · corrodedFWD CARGO STA 465 LEFT LONGERON 29 ON AFT SIDE OF FRAME SUPPORT CLIP HAS CORROSION REMOVED CLIP IAW DC9 SRM 51-30-5 TO GAIN ACCESS REMOVED CORR L 3" X W 2" IAW DC9 SRM 51-10-3 ORG .063 IAW DAC DWG DL5911412 REV DV. REMOVED .013 REMAINING.050 OUT OF LIMITS IAWSDR DALA1131269866Doubler · crackedFUSELAGE EXTERIOR, UPPER ANTI COLLISION LIGHT, MOUNTING DOUBLER CRACKED AT FWD END AS MARKED. REMOVED CRACKED DOUBLER IAW DC9 SRM 51-30-2 FABRICATED AND INSTALLED REPLACEMENT DOUBLER IAW DC9 SRM 51-10-2, 51-30-2.SDR DALA1128319875Skin · dentedFUSELAGE DENT AT BS 984 AND LONGERON 17R WITHIN 1 FROM THE FRAME. MEASURED DENT AT EXT SKIN BS 984, L17R. OUT OF LIMITS IAW SRM 53-04, FIG 38 COLD FORM SKIN BACK AT SKIN BS 982-985, 1" ABOVE L17R IAW SRM 53-04, FIG 38, PAR AG 4B. FABRICATED DOUBLER IAW SRM 5SDR DALA1128289875Floor Support · corrodedSUPPORT ANGLE HAS AREAS OF CORROSION BL-0 FROM STA 160 TO 313. REMOVED CORR IAW SRM 51-10-3, PG 46. OUT OF LIMITS IAW SRM 53-01 FIG 1, SHEET 3, PG 8, REM FLOOR SUPPORT ANGLE IAW SRM 51-30-5, FLOOR SUPPORT ANGLE IAW SRM 53-13-1, FIG 11, SHEET 1-2, PG25-26, LSDR DALA1128279875Floor Panel · corrodedCABIN FLOOR PNL NR 37 HAS SURFACE CORROSION AT OTBD FASTENER HOLES. REMOVED CORROSION REF SRM 51-10-3. ORIG MATERIAL IS .020 REF SRM 53-23-0. MAX ALLOWABLE MATERIAL LOSS IS .004 MATERIAL LOSS .007, OUT OF LIMITS, REF SRM 53-01, PG8 FIG 1. REMOVED CHANNELS SDR DALA1134939866Seat Track · corrodedMAIN CABIN STA 200 TO 247 RBL 44 SEAT TRACK HAS CORROSION. REMOVED SEAT TRACK STA 200-266 AND SPLICE. BOTH OUT OF LIMITS. LOCATED, DRILLED, DEBURRED, TREATED, PRIMED AND INSTALLED NEW SEAT TRACK AND SPLICE. ACCOMPLISHED IAW SRM'S 51-30-1, 51-30-2, 51-30-5,SDR DALA1134929866Floorbeam · corrodedMAIN CABIN FLOORBEAM STA 200 LBL1 TO LBL20 HAS CORROSION. FLOORBEAM FOUND TO BE OUT OF LIMITS IAW SRM 53-01 FIG 1. REMOVED FLOORBEAM. FABRICATED LOCATED DRILLED DEBURRED IAW SRM 51-10-4. TREATED AND PRIMED AND INSTALLED NEW FLOORBEAM IAW SRM 51-10-3 AND 5SDR DALA1131289866Floor Support · corrodedMAIN CABIN FLOOR SUPPORT STA 200 RBL 1 TO RBL 20 HAS CORROSION. FLOOR SUPPORT FOUND TO BE OUT OF LIMITS ORIG MAT .060 REMOVED.030 REMOVED FLOOR SUPPORT IAW DC9 SRM 51-30-5. RECEIVED, FABRICATED, LOCATED, DRILLED, DEBURRED, TREATED & PRIMED AND INSTALLED IAW SDR DALA1130669866Floor Support · corrodedMAIN CABIN STA 256 TO 275 LBL 20 FLOOR SUPPORT HAS CORROSION SIZE 1" X 1" ORG MAT .094 REMOVED .010 REMANING.084 FLOOR SUPPORT OUT OF LIMITS REMOVED FLOOR SUPPORT IAW DC9 SRM 51-30-2 RECEIVED MAT. FABRICATED, LOCATED DRILLED, DEBURRED, TREATED & PRIMED, INSTSDR DALA1137009866Frame · crackedAFT ACC COMPT STA 1234 CANTED FR CRACKED. REMOVED TAIL ANTI-ICE DUCT REPAIRED FRAME STA 1234 LT IAW DC-9 SRM 51-30-1 AND REINSTALLED TAIL ANTI-ICE DUCT LEAK AND OPS CHECKED GOOD P134 27 MAY 11. REQUIRED INSPECTION COMPLETED.SDR DALA1128399873Acm · overservicedACFT RETURNED TO DEPARTURE DUE TO SMOKE IN THE CABIN. LAV SMOKE DETECTORS SOUNDED AND LT AIR COND SUPPLY TEMP HIGH LIGHT ILLUMINATED. QRH WAS COMPLIED WITH AND THE LT PACK WAS SHUTDOWN. MX RAN BOTH ENGINES AT TAKEOFF POWER AND CRUISE POWER FOR 5 MINUTES EASDR DALA1127659858Intercostal · wornMAIN CABIN AT STA 617 LT SIDE, UPPER SURFACE OF INTERCOSTAL IS WORN IN SEVERAL SPOTS, AT FLOOR SUPPORT. 60-005. REMOVED 2" ANGLE AND INTERCOSTAL AT STA 617 LT SIDE IAW SRM 51-30-2 PG 1 INSTALLED REPLACEMENT INTERCOSTAL "L" ANGLE AND ATTACHED "Z" ANGLE TO FLOORSDR DALA1127639875Web · crackedAFT CABIN LT STA 1100-1110, LBL 44-LBL 56 SUB FLOOR WEB IS CRACKED. FABRICATED 2 EA DOUBLERS AND 1 EA FILLER. INSTALLED 2 EA DOUBLERS AND FILLERS 1 EA AT AFT CABIN LT STA 1100-1110, LBL 44 TO LBL 56 IAW SRM 51-30-2 PG:1-2 AND 51-30-05 PG:1-3 INSTALLED FITSDR DALA1127619858Floorbeam · wornMAIN CABIN AT STA 636 LT SIDE, UPPER SURFACE OF FLOORBEAM IS WORN IN SEVERAL SPOTS, AT FLOOR LEVEL 60-003. BLENDED OUT DAMAGE MAIN CABIN AT STA 636 LT SIDE LBL 14 IAW SRM 51-10-3 MATERIAL THICKNESS FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 (PG8). FABRICATSDR DALA1132789863Power Supply · inoperativeEMERGENCY EXIT LIGHT AT THE FORWARD EMERGENCY ESCAPE DOOR WAS INOP. LINE MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY, LOCATED AT STATION 729, PER THE WIRING DIAGRAM MANUAL. OPERATIONAL CHECK WAS SUCCESSFUL.SDR DALA1128219871Bracket · crackedAFT ACC COMPT FS1258 CTR, VERTICAL BRACKET IS CRACKED. LOWER RT SIDE RADIUS GAINED ACCESS. STOP DRILLED CRACK. NDT VERIFIED CRACK CONTAINMENT. FABRICATED AND INSTALLED 2 EA REPAIR ANGLES FROM.032 7075T6. RESTORED AREA. IAW SRM 51-30-1, 51-30-5, 53-01, FIG 2SDR DALA1127539871Spar · crackedLT ELEVATOR OTBD T/E SPAR CRACKED, OTBD HOLE IN SPAR ELONGATED. CUT OUT DAMAGED SECTION OF CHANNEL 7" LONG IAW SRM 51-70-5. NDT TO VERIFY DAMAGED CONTAINED. ORIG MAT 2024T3 .025 IAW SRM 51-70-5. FABBED 1EA CHANNEL MAT 2024T3, PO 1120031. MAT FOR SPLICE 20SDR DALA1127529858Seat Track · corrodedSEAT TRACK STA 200 TO 280, RBL 22 HAS CORROSION. REMOVED CORROSION IAW SRM 51-10-3 ORIGINAL MATERIAL THICKNESS IS .090" MAT LOSS RANGE FROM .040"-.060" IN SEVERAL AREAS, OUT OF LIMITS. REMOVED SEAT TRACK IAW SRM 51-30-5 FABED SEAT TRACK FROM PN 09-5300-3-151SDR DALA1127499858Skin · damagedLOWER FUSELAGE STA Y390, BETWEEN LONGERON 28RT AND LONGERON 29R SKIN WITH DENT. COLD FORMER SKIN BACK TO ORIGINAL CONTOUR AT LOWER FUSELAGE FABED AND INST INTERNAL REPAIR DOUBLER IAW SRM 53-04, FIG 38 VIEW G NDT CHECK NO CRACKS IAW NDT SPM 06-10-01.001 MEASUSDR DALA1127469858Skin · dentedCABIN FLOOR PANEL 85D HAS SHARP DENTS AND SCREWS PULLED THRU TOP SKIN. REPAIRED PUNCTURE AND CRACKED HAT CHANNELS IAW SRM 53-01, P7, FIG 1. OUT OF LIMITS IAW SRM 51-50-1, PG 1-2, ENDS OF HAT CHANNELS IAW SRM 51-10-2. NDT CHECK FOUND IAW NDT SPM 06-10-01.001SDR DALA1127459858Skin · corrodedCABIN FLOOR PANEL 32D FWD END IS BENT UP, 1EA RIVET IS HAS CORROSION AROUND SCREW HOLES ON TOP SKIN. REMOVED CABIN FLOOR PANEL. REMOVED CRACKED SECTION AND REPAIRED CABIN FLOOR PANEL IAW 53-05, FIG 1, PG10. TREATED AND PRIMED BARE AREAS IAW SRM 51-10-3, ITEMSDR DALA1127449858Skin · damagedCABIN FLOOR PANEL 9D HAS PUNCTURE IN TOP SKIN. R & R PANEL 91D FLOOR CABIN AREA IAW SRM 53-05, FIG 2, PG 9 AND 11. NDT FOUND NO CRACKS AT REPAIR AREA IAW NDT SPM 06-10-01-001. FABRICATED REPAIR FILLER AND DOUBLER IAW SRM 51-10-3, PG 31, 32, 40, 41. INSTALL
Back to Mcdonnell Douglas DC-9-51