Mcdonnell Douglas DC-9-51
Service difficulty reports · 4,581
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC951' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA1115519877Structure · crackedOVERSIZED RIVNUT HOLE ON AFT SIDE OF FWD CARGO DOOR IS MISSING RIVNUT AND HOLE IS CRACKED. FABRICATED REPAIR DOUBLER IAW SRM 52-03, FIG 1. ALODINED REPAIR DOUBLER IAW SRM 51-10-3, PARA 21. PRIMED REPAIR DOUBLER IAW SRM 51-10-3B, PARA 2 F . INSTALLED REPAIR SDR DALA1123009870Keelbeam · crackedKEEL AREA BETWEEN DOORS, THRU ACCESS 5501NW LBL 6 ANGLE CRACKED APPROX 2 INCHES. CUT OUT DAMAGED ANGLE IAW ENGINEERING SERVICE REQUEST 2496N01328 AND DC9 SRM 53-01. FABRICATED NEW ANGLE FROM 7075-0 .063 AND REPAIR ANGLES FROM7075-T6 .032 IAW DWG 9923459. HESDR DALA1116379870Attach Fitting · crackedE & E COMPT STA 180 LBL-1 INTERCOSTAL CLIP CRACKED. REMOVED CRACKED INTERCOSTAL CLIP FS 180, LBL-1, E & E CEILING. FABRICATED, TREATED, PRIMED, AND INSTALLED REPLACEMENT CLIP IAW SRM 51-30-02, 51-10-02,51-10-04, 51-10-03, AND 51-30-05. REQUIRED INSPECTION COSDR DALA1115869873Vane · delaminatedLEFT WING CENTER FIXED FLAP VANE DELAMINATED 0N IB END. REMOVED L/WING FLAP CENTER FIXED VANE IAW DC-9 MM 27-51-03. REPLACED FLAP FIXED VANE DUE TO DELAMINATION OUT OF LIMITS PER TRAVELER 2477NO1195. INSTALLED NEW SERVICEABLE VANE IAW DC9 MM 27-51-03. OPSSDR DALA1115839870Panel · damagedRT WING STA XRS-353 FIXED PANEL GOUGED ON LOWER SURFACE T/E. REMOVED DAMAGED SKIN MEASURING .3750" RADIUS. FAB FILLER & DOUBLER FROM .040. REMOVED AL CAD AND PREPARED ALL MATING SURFACES FOR BOND. BONDED FILLER & DOUBLER FOR 90 MINUTES AT 230 DEGREES IAW SSDR DALA1115799877Skin · corrodedFUSELAGE SKIN CORROSION AT STA 1116, STR 28L, FOUND DURING MAUS SCAN INSP. AREA FOUND TO BE OUT OF LIMITS IAW SRM 53-04, PG 218, FIG 38. CUT OUT DAMAGE AREA IAW SRM 53-04 PG. FABRICATED REPAIR PARTS IAW SRM 53-04 TREATED AND PRIMED REPAIR PARTS IAW SRM 51-SDR DALA1115789878Cargo Track · crackedAFT CARGO STA 1088 LT TIE DOWN TRACK ATTACH FITTING TO FRAME CRACKED. CUSTOMER FURNISHED PART. LOCATED, DRILLED, DEBURRED IAW SRM 51-10-4. INSTALLED IAW SRM 51-30-5. P106.SDR DALA1115779878Cargo Track · crackedAFT CARGO STA 1167 LT TIE DOWN TRACK ATTACH FITTING TO FRAME CRACKED. REMOVED AFT CARGOSTA 1167 LT TIEDOWN TRACK FITTING RECIEVED CUSTOMER FURN PART, LOCATED, DRILLED, DEBURRED IAW SRM 51-10-4, INSTALLED IAW SRM 51-30-5. P106.SDR DALA1115699878Floorbeam · crackedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CRACKED AND HAS CORROSION. REMOVED CRACKED FLOOR SUPPORT AND FABRICATED NEW FROM IAW SRM 53-13-2, FIG 4 LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3 INSTALLED IAW SRM 51-30-5SDR DALA1115689878Cusp Web · crackedMAIN PASSENGER CABIN STA 754, RBL 52, CUSP WEB IS CRACKED. R & R CUSP WEB, STA 754 TO 794 IAW SRM 51-30-2 AND 51-30-5 AND DWG 9910151 & SG09530019. P106 REQUIRED INSPECTION COMPLETED.SDR DALA1115679878Floor Support · damagedUPON REMOVAL OF FLOOR SUPPORT FOUND A DOUBLE DRILLED HOLE IN FLOOR BEAM AT STA 636, LBL-7, CORRECTED. REMOVED DOUBLER, DRILLED HOLE BY CUTOUT STA 636, LBL-7. FABRICATED ANGLE FROM AND FILLER FROM IAW SRM 53-05, FIG 79A LOCATED AND DRILLED IAW SRM 51-10-4. SDR DALA1115659878Floorbeam · chafedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 TOP FLOORBEAM CHAFED. CORRECTED, REMOVED PREVIOUS REPAIR, STAINLESS STEEL STRIP AND FABRICATED NEW IAW SRM 53-05 FIG 20. LOCATED AND DRILLED IAW SRM 51-10-4. TREATED AND PRIMED IAW SRM 51-10-3. INSTALLED IAW SRM 53-SDR DALA1115589878Web · crackedAFT ACCESSORY LT SIDE WEB ABOVE RAIN BOX AFT END CRACKED. CORRECTED, STOP DRILLED CRACK IAW SRM 53-01, FIG 2, SHT 3 FABRICATED AND DRILLED REPAIR DOUBLER IAW SRM 51-10-2 AND 51-10-4 AND 53-01 FIG 2, SHT.3. INSTALLED REPAIR DOUBLER IAW SRM 53-01 FIG 2, SHT.3 SDR DALA1115579878Longeron · crackedMAIN CABIN STA 313, L17L CRACKED AT FASTENERS R & R L16L IN MAIN CABIN AREA AT STA 229 TO STA 313 IAW SRM 51-30-2 51-30-5 51-20-0 53-02 FIG 18, SHT 1. LONGERON PN S2777922-3-25000, SPLICE CAP PN 7637813-3. REQUIRED INSP COMPLETED.SDR DALA1115569878Longeron · crackedMAIN CABIN, STA 332, L16R, LONGERON CRACKED. R & R L16R IN MAIN CABIN AREA AT STA 229 TO STA 370 IAW SRM 51-30-2 51-30-5 51-20-0 53-02 FIG 18 SHT 1, LONGERON PN S2777922-3-25000, SPLICE CAP PN 7637813-3. REQUIRED INSP COMPLETED.SDR DALA1115559878Longeron · crackedMAIN CABIN STA 313, RT LONG 17 CRACKED. R & R L17R IN MAIN CABIN AREA AT STA 307 TO STA 340 IAW SRM 51-30-2 51-30-5 51-20-0 53-02 FIG 18 SHT, 1 LONGERON PN S2777922-3-25000, SPLICE CAP PN 7637813-3. REQUIRED INSP COMPLETED.SDR DALA1122779870Cap · corrodedAFT CARGO STA 1167 RIGHT LONG 21 LONG END CAP HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 51-10-3. ORIGINAL THICKNESS WAS .094 IAW DRAWING 4914957. UT THICKNESS IAW NDT SPM 04-00-07 FOUND REMAINING THICKNESS IS .072 OUT OF LIMITS IAW DC9 SRM 53-01. REMOVSDR DALA1118489870Support · crackedAFT ACCESSORY STA 1258 LEFT LONG. 5 O/B FAN VERTICAL SUPPORT CRACKED. REMOVED CRACKED SUPPORT IAW DC-9 SRM 51-30-2 & 51-30-5. LOCATED DRILLED & DEBURRED NEW SUPPORT BRACKET IAW DC-9 SRM 51-10-4. INSTALLED NEW BRACKET IAW DC-9 SRM 51-30-2 & 51-30-5.SDR DALA1116799877Longeron · crackedLONGERON 3L CRACKED AT FRAME INTERSECTION STATION BS 160. REPAIRED LONGERON SECTION 3L, STA BS 160 IAW DC9 SRM 53-02, FIG 18, PAGES 50-52.SDR DALA1116049870Intercostal · damagedMAIN PAX CABIN/GALLEYS; INTERCOSTAL BETWEEN STA 294 AND 313 AND BL-0, HAS ELONGATED AND OVER SIZED HOLES. REMOVED INTERCOSTAL IAW SRM 51-30-5. FABRICATED NEW INTERCOSTAL FROM 2024-T3 .025, IAW SRM 53-13-2 FIG 4 AND 51-60 FIG 4 AND 51-60 FIG 1 INSTALLED NEW ISDR DALA1115809878Web · crackedAFT ACCESSORY T/H SIDE STA 1209 WEB CRACKED AT LIGHTNING HOLE. STOP DRILLED END OF CRACK IAW SRM 53-01, FIG 2. FABRICATED DOUBLER IAW SRM 53-01, FIG 2. TREATED & PRIMED REP DOUBLER IAW SRM 51-10-3 AND INSTALLED REPAIR DOUBLER AT AFT ACCESSORY T/H SIDE STA 1SDR DALA1115749877Door Frame · crackedAFT CARGO COMPT LOWER JAMB AT STA 1068 AND STR 28R STRINGER CLIP CRACKED. REMOVED 2 EA SPLICE REPAIR AND 1 EA TEE BRACKET AT STA 1068 AND 28R AFT5 CARGO IAW SRM 51-30-15, PG 29. REMOVED 1 EA CRACKED CLIP IAW SRM 51-30-15, PG 29, LOCATED AND DRILLED NEW STR CSDR DALA1115729877Floor Support · corrodedCORROSION ON BEAM FROM STA 160 TO 200 AT PANELS 18 AND 19, ENTIRE LENGTH. REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS IAW FIG 1, REMOVED CORRODED BEAM, FABRICATED, TREATED AND PRIMED IAW SRM 51-10-4 AND 53-13-1, FIG 11 INSTALLED BEAM FLOOR SUPPORT ON STA SDR DALA1115639878Floor Panel · puncturedMAIN CABIN METAL SKIN FLOOR PANEL NR 73 HAS 1EA PUNCTURED HOLE. CUTOUT PUNCTURED AREA (2.0625" X 1.0625") IAW SRM 53-01, FIG 4 HFEC VERIFIED DAMAGE. REMOVED IAW NDT SPM 06-10-01.001 ORIG MAT .020, 7075T6 IAW SRM 53-23- FIG 5 FABRICATED & LOCATED & DRILLED IASDR DALA1115599877Floor Panel · corrodedFLOOR PANEL 73, HAS NUMEROUS SCREW HOLES CORRODED, BLENDED. FLOOR PANEL FOUND TO BE OUT OF LIMITS IAW SRM 53-01, FIG 1 AND SRM 53-25-0, FIG 4. RECEIVED MATL FOR FLOOR PANEL IAW SRM 53-23-0, FIG 5, FABRICATED FLOOR PANEL IAW SRM 53-23-0, FIG 5. TREATED AND SDR DALA1115549877Longeron · damagedRT STATIC PORT PLATE UPPER LONGERON HAS HOLES DRILLED IN UPPER CAP TRIMMED OUT DAMAGE AT LONGERON 24R, BETWEEN STA 522 TO 541 IAW AMM DC9-A-53-10-04-801-663-A-A, PERFORMED HFEC SURFACE INSP AT TRIMMED OUT AREA. NO CRACKS NOTED IAW NDT SPM 06-10-01.001. FABRISDR DALA1115529873Floor Panel · corrodedMAIN CABIN METAL FLOOR PANEL NR 21 HAS CORROSION FASTENER HOLES. REMOVED CORROSION FROM FLOOR PANEL IAW SRM 51-10-3. FOUND TO BE OUT OF LIMITS. FABBED FLOOR PANEL & 2 EA HAT CHANNELS IAW SRM 51-10-2. DRILLED, COUNTERSUNK FASTENER HOLES IAW SRM 51-10-4. SDR DALA1121209870Intercostal · corrodedFWD CARGO STA 440 LBL 10 CORROSION ON INTERCOSTAL REMOVED CORROSION IAW DC9 SRM 51-10-3, UPON REMOVAL FOUND INTERCOSTAL TO BE CRACKED. REMOVED INTERCOSTAL IAW SRM 51-30-5. FABRICATED NEW INTERCOSTAL FROM 7075-0 .050 AND HEAT TREATED ON PEMCO TRAVELER 2496N01SDR DALA1120579870Floor Panel · corrodedCORROSION ON CABIN FLOOR PNL 26 CORROSION FOUND TO BE OUT OF LIMITS, REMOVED DOUBLER, CHANNELS RECEIVED MAT .032 7075-T6 & HAT CHANNEL P/N 5290282, FABED, LOCATED, DRILLED, DEBURRED NEW PANEL, TREATED AND AND INSTALLED HAT CHANNELS AND DOUBLER IAW DC9 SRM 51-1SDR DALA1120529870Angle · gougedMAIN CABIN STA 1136 RBL 54 RIGHT PYLON BULKHEAD ANGLE AT FLOORBEAM GOUGED. BLENDED GOUGE. ORIGINAL .076 REMOVED OVER 50 PERCENT MAT. OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1 DWG 9912243. REMOVED AND REPLACED ANGLE AND END FITTING IAW DC-9 SRM 51-30-5.SDR DALA1119269870Cusp Web · crackedMAIN CABIN STA 712 RIGHT SIDE CUSP WEB CRACKED UNDER HORSE SHOE COLLAR APPROX 2 INCHES. CPCP TASK 53-53300. REMOVED, FABRICATED, AND INSTALLED DOUBLER IAW DRAWING SG09530019. APPLIED REPAIR TAG IAW PROCESS STANDARDS 900-5-1 NR 4.SDR DALA1118739870Floor Panel · crackedMAIN CABIN FLOOR PNL 69 IS CRACKED ON END AT FASTENER HOLE REMOVED CRACKED EXPANSION JOINT IAW DC9 SRM 51-30-2. LOCATED AND DRILLED NEW EXPANSION JOINT, P/N 9957925-109 IAW SRM 51-10-4. INSTALLED NEW EXPANSION JOINT TO FLOOR PANEL IAW SRM 51-30-2 P102.SDR DALA1118539870Floor Panel · damagedMAIN CABIN FLOOR PNL 78 IS CRACKED ON END AT FASTENER. REMOVED DAMAGE AT FWD END OF PANEL & HAT CHANNEL IAW DC9 SRM 53-05 FIG 1. HFEC INSPEC IAW DC9 NDT SPM 06-10-01. FOUND DAMAGE REMOVED. REPAIRED PANEL IAW DC9 SRM 53-05 FIG 1. INSTALLED ID TAG PER DPS 9SDR DALA1118479870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C10 HAS CORROSION. REMOVED CORROSION IAW DC-9 SRM 51-10-3. FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1. FABRICATED NEW PANEL FROM 2024-T3 .063 ALUMINIUM IAW DRAWING 9C25-90981 AND DC-9 SRM 51-10-2. DRILLED NEWSDR DALA1118469870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C11 HAS CORROSION. REMOVED CORROSION IAW DC-9 SRM 51-10-3. FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1. FABRICATED NEW PANEL FROM 2024-T3 .063 ALUMINUM IAW DRAWING 9C25-90981 AND DC-9 SRM 51-10-2. DRILLED AND CSDR DALA1118459870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C8 HAS CORROSION. REMOVED CORROSION IAW DC9 SRM 51-10-3. ORIGINAL THICKNESS WAS .063 IAW DRAWING 9C25-90981, AFTER BLEND THICKNESS IS .044 OUT OF LIMITS IAW DC9 SRM 53-01. FABRICATED NEW SUPPORT FROM 2024-T3.063 LOT 11SDR DALA1118449870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C9 HAS CORROSION CORR BY FILLINGIM 316479. REMOVED CORROSION IAW DC9 SRM 51-10-3. ORIGINAL THICKNESS WA.063 IAW DRAWING 9C25-90981, AFTER BLEND THICKNESS IS .041 OUT OF LIMITS IAW DC9 SRM 53-01. FABRICATED NEW SUPPORT SDR DALA1118439870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C15 HAS CORROSION. REMOVED CORROSION IAW DC-9 SRM 51-10-3. FOUND TO BE OUT OF LIMITS IAW DC-9 SRM 53-01 FIG 1. FABRICATED NEW PANEL 2024-T3 .063 ALUMINUM IAW DRAWING 9C25-90981 AND DC-9 SRM 51-10-2. DRILLED AND COUNTESDR DALA1118429870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C5 HAS CORROSION. CORR BY FILLINGIM 316479 STA DHN 03MAR11 ATA REMOVED CORROSION IAW DC9 SRM 51-10-3. ORIGINAL THICKNESS WAS.063 IAW DRAWING 9C25-90981, AFTER BLEND THICKNESS IS OUT OF LIMITS IAW DC9 SRM 53-01. FABRICATSDR DALA1118419870Floor Support · corrodedPARTS RACK 92B FWD CARGO FLOOR SUPPORT C14 HAS CORROSION. REMOVED CORROSION IAW DC-9 SRM 51-10-3. FOUND TO BE LIMITS IAW DC-9 SRM 53-01 FIG 1. FABRICATED NEW PANEL FROM 2024-T3 .063 ALUMINUM IAW DRAWING 9C25-90981 AND DC9 SRM 51-10-2. DRILLED AND COUNTERSUSDR DALA1117179870Floor Panel · brokenMAIN CABIN FLOOR PNL 74 CORNER OF PNL IS BROKEN OFF CUT OUT DAMAGE (2 X .75 INCH) IAW DC/9 SRM 51-10-2. FABRICATED, LOCATED, DRILLED AND INSTALLED REPAIR DOUBLER AND FILLER USING.020 IAW DC/9 SRM 53-23-00 FIG 5 AND 51-30-2. REQUIRED INSPECTION COMPLETED 10 MSDR DALA1116839870Floor Panel · crackedMAIN CABIN FLOOR PANEL 65 HAS 4 EA FASTENER HOLES CRACKED. REMOVED DAMAGE BY CUTOUT 2.25" X 21"-ORIGINAL MAT. 7075T-6.025 IAW DC-9 SRM 53-01 FIG 4-NDT VERIFIED DAMAGE. REMOVED IAW NDT SPM 06-10-01 RECEIVED MAT 7075-T6-.025. FABBED LOCATED, TRIMMED, DRILLED,SDR DALA1116829870Floor Support · corrodedMAIN CABIN STA 775 BETWEEN BL 0 AND LBL 22 FLOOR SUPPORT HAS CORROSION AND CRACKED. REMOVED DAMAGED FLOOR SUPPORT, OBTAINED MATERIAL .0502024T3 FORMED, DRILLED, DEBURRED, TREATED, PRIMED, SEALED, INSTALLED, IAW DC-9 SRM'S 51-30-2 53-13-3 FIG 11 51-10-2, 51-10SDR DALA1116809870Floor Support · chafedMAIN CABIN STA 617 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CHAFED. BLENDED AREA IAW DC9 SRM 53-13-2 FIG 4 AND 51-10-3. ORIG THICKNESS WAS .050 IAW DC9 SRM 53-13-2 FIG4, AFTER BLEND THICKNESS IS .027, OUT OF LIMITS IAW DC9 SRM 53-01. REMOVED AND FABRICATED NEWSDR DALA1116569870Floor Support · crackedMAIN CABIN STA 655 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CRACKED. REMOVED FLOOR SUPPORT, FABBED NEW FLOOR SUPPORT, LOCATED, DRILLED, TREATED, PRIMED AND INSTALLED NEW FLOOR SUPPORT IAW DC9 SRM 51-30-2, 53-13-2 FIG 1, 51-10-2, 51-10-4, 51-10-3. REQUIRED INSPESDR DALA1116559870Vertical Support · crackedMAIN CABIN JUST UNDER FLOOR STA 775 RBL-44 VERTICAL SUPPORT CRACKED APPROX 2 INCHES. REMOVED CRACKED SUPPORT, RECEIVED NEW SUPPORT. LOCATED, DRILL, DEBURRED, TREAT, PRIME & INSTALL IAW DC-9 SRM 51-30-2, 51-30-5, 51-10-4, 51-10-3. REQUIRED INSPECTION COMPLETSDR DALA1116369870Cusp Web · damagedMAIN CABIN STA 770, LBL-50 CUSP WEB PREVIOUS REPAIR NOT MEETING FASTENER REQUIREMENT. REMOVED EXISTING DOUBLER IAW SRM 51-30-8. FABRICATED NEW DOUBLER FROM 7075-T6 .050 IAW SRM 53-13-3, FIG 11 AND SRP DC9-53-10-16-801-663A-A. INSTALLED NEW DOUBLER IAW SRM 5SDR DALA1116359870Floor Panel · chafedMAIN CABIN FLOOR PANEL 81 CHAFED THROUGH AT FASTENER HOLE, FWD END. INSTALLED REPAIR DOUBLER AQUIRING MAT IAW DC9 53-23-0 .025 7075T6 PO 1120200 FABED. REPAIR IAW SRM 53-01, TREATED & PRIMED IAW SRM 51-10-3S. REQUIRED INSP COMPLETED.SDR DALA1116349870Floorbeam · chafedMAIN CABIN STA 655 BETWEEN BL-0 AND LBL-22 FLOORBEAM CHAFED ON TOP SIDE. BLENDED AREA IAW SRM 53-01. ORIGINALTHICKNESS WAS .125 IAW SRM 53-13-2, AFTER BLEND THICKNESS IS .073 OUT OF LIMITS IAW SRM 53-01. FABRICATED 5 EA REPAIR PLATES IAW SRM 53-05, FIG 20. SDR DALA1116339870Floorbeam · chafedMAIN CABIN STA 636 BETWEEN BL-0 AND LBL-22 FLOOR SUPPORT CHAFED. CORR BY FILLING IM 316479 BLENDED SUPPORT IAW SRM 51-10-3. ORIGINAL THICKNESS WAS .050 IAW SRM 53-13-2, AFTER BLEND THICKNESS IS .027 OUT OF LIMITS IAW SRM 53-01, FIG 1 FABBED NEW SUPPORT IAW S
Back to Mcdonnell Douglas DC-9-51