Pratt & Whitney PW4060

Service difficulty reports · 7,186

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE engine_model_key = 'PW4060'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR HALA0700286Fitting · leakingETOPS SIGNIFICANT SYSTEM, R GEN DRIVE LIGHT CAME ON APPROACH, TURNED ON APU. PERFOMED BPCU BITE PER FIM 24-20-00. ALL ELECTRICAL SYSTEMS CHECK GOOD. NO FAULTS. FOUND IDG OVERFLOW SERVICE FITTING LEAKING. REPLACED SERVICE AND OVERFLOW SERVICE ADAPTERS PER Jul 14, 2007 · N582HA · Boeing 76733A · AC Generation SystemSDR 2007UALA02626Engine · overtempNR 2 ENGINE EXPERIENCED OVERTEMP DURING CLIMB. [07-27-07] OIL TEMPERATURE IN YELLOW BAND DURING CLIMB. RETURNED TO FIELD IAW FLT MANUAL IRREG PROCEDURE 14.40.17. ORDMM FOUND OIL LEAK AT FUEL OIL COOLER BYPASS VALVE SOLENOID MATING SURFACE. REPLACED SOLJul 14, 2007 · N654UA · Boeing 767322 · Engine (Turbine/Turboprop)SDR 2007UALA02627Transformer · out of rigCAPTAIN REPORTED, T/E FLAP DISAGREE ON FINAL. [08-17-07] FSEU BITE CARRIED OUT WITH FLAP HANDLE SET FOR 30 AND READOUT SHOWING 20. THIS CONFIG RESULTED FROM THE FLAP LEVER ROTARY VARIABLE DIFFERENTIAL TRANSFORMER BEING IN MISRIGGED CONFIGURATION & OUTBD Jul 14, 2007 · N662UA · Boeing 767322 · Trailing Edge Flap Control SystemSDR 2007UALA02616Blade · fracturedCREW SHUTDOWN THE NR 1 ENGINE DUE TO VIBRATION. LANDED UNDER AMBER ALERT. [08-14-07] ENGINE REPLACED AT IAD. SHOP TEARDOWN FOUND ONE STAGE-2 HPT BLADE FRACTURED AT THE PLATFORM. THIS CAUSED AN UNBALANCE THAT PRODUCED HEAVY VIBRATION. FAILURE RESULT OFJul 13, 2007 · N653UA · Boeing 767322 · Turbine SectionSDR 2007UALA02612Hose · damagedRIGHT OVERWING SLIDE CYLINDER LWR INFLATION HOSE IS KINKED AND COLLAPSED. [08-07-07] REPLACED HOSE IAW 20-10-10. SLIDE PROBLEM ROOT CAUSE: SLIDE & INFLATION HOSE ARE IN AN AREA CONTAINING MANY HYDRAULIC LINES & SERVICING ACCESS; SUSPECT HOSE DAMAGED BY SJul 12, 2007 · N649UA · Boeing 767322 · Escape SlideSDR 2007UALA02613Warning Light · illuminatedLEFT GEN DRIVE LIGHT ILLUMINATED WITH ASSOCIATED EICAS L GEN DRIVE DISC MSG. [08-07-07] REPLACED LT IDG AS PER MM 24-11-01, FINAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.Jul 12, 2007 · N651UA · Boeing 767322 · Central WarningSDR 2007UALA02531Fire Detector · faultyFWD CARGO DETECTOR NR 2 AND GROUND PROXIMITY SYS STATUS WILL NOT CLEAR. [08-08-07] RESTARTED SYSTEM. FWD CARGO "DET 2" MSG CLEARED. GROUND PROX SYSTEM MESSAGE STILL PRESENT. RESET GLIDESLOPE DISCRETE PER MM34-46-00 MESSAGE CLEARED. MESSAGE REPEATED 8 DJul 10, 2007 · N642UA · Boeing 767322 · Fire DetectionSDR 2007UALA02533Drain · cloggedRTFL DUE TO AFT LAV TANK INOP LIGHT ILLUMINATED. CREW REPORTED LAVS FULL AND OVERFLOWING. RETURNED TO FIELD DUE TO NO FUNCTIONING LAVS. FOUND DRAINS CLOGGED. UNPLUGGED DRAINS. FOUND 9 CLOTH NAPKINS, 2 RUBBER LAV DOOR SEAL, AND 2 PIECES OF POLYURETHANIC Jul 10, 2007 · N643UA · Boeing 767322 · Waste Disposal SystemSDR 2007UALA02559Latch · wornRIGHTHAND OVERWING SLIDE COMPARTMENT DOOR NR 3 LATCH WORN. REMOVED & REPLACED LATCH AND KEEPER.Jul 10, 2007 · N649UA · Boeing 767322 · Escape SlideSDR 2007UALA02497Hose · damagedRIGHT OFF WING ESCAPE SLIDE INFLATION HOSE FROM INFLATION CYLINDER IS CONTAMINATED WITH HYDRAULIC FLUID AND IS DETERIORATED. [08-08-07] HOSE IS DETERIORATED AND WALLS HAVE COLLAPSED FROM LONG TERM CONTACT WITH HYDRAULIC FLUID. REPLACED HOSE ASSY. SLIDE Jul 9, 2007 · N659UA · Boeing 767322 · Escape SlideSDR 2007UALA02551Battery · faultyEMERGENCY FLASH LIGHT BETWEEN 1L & 1R FLIGHT ATTENDANT SEAT DOES NOT BLINK. [08-08-07] REPLACED BATTERY AND SEAL. AIRCRAFT OK FOR SERVICE.Jul 9, 2007 · N641UA · Boeing 767322 · Emergency EquipmentSDR 2007UALA02552Lamp · damagedEMERGENCY LIGHT STRIP FOUND TORN UP IN LEFT AISLE ADJACENT TO BUSINESS CLASS GALLEY. [07-27-07] REPLACED EEL LAMP ASSY OPS NORMALJul 9, 2007 · N661UA · Boeing 767322 · Emergency LightingSDR 2007UALA02456Hose · contaminatedRIGHT OFF WING ESCAPE SLIDE INFLATION HOSE FROM INFLATION CYLINDER IS CONTAMINATED HYDRAULIC FLUID, AREA OF CONTAMINATION IS ADJACENT TO THE HYD SYSTEM SERVICING SELECTOR. PRESSURIZED HYD SYSTEMS AND NO LEAKS DETECTED. PIPE IS SPONGY AND WALLS HAVE COLLAPSEDJul 8, 2007 · N654UA · Boeing 767322 · Escape SlideSDR 2007UALA02502Skin · damagedLEFT WING NR 6 LEADING EDGE SLAT HAS A FOUR INCH LONG BY THREE QUARTER INCH DEEP PIECE OF FIBERGLASS MISSING FROM THE LOWER EDGE CLOSE OUT PANEL. [08-08-07] REPAIRED BY BACKSHOP 273 MECHANIC. REPAIRED PER SHOP MM AND INSPECTED. RETURNED TO SERVICE.Jul 7, 2007 · N646UA · Boeing 767322 · Leading Edge DevicesSDR 2007UALA02505Connector · faultyACRID ELECTRICAL ODOR IN AFT GALLEY AREA REPORTED AFTER TAKEOFF, NO SMOKE NOTED. [08-08-07] FOUND GALLEY CART CONNECTOR WITH PINS DIRTY AND PINS BENT. STRAIGHTENED PINS AND CLEANED CONNECTORS ON BOTH AIRCRAFT AND CART SIDES OF CONNECTION. LEFT CART WORKINJul 7, 2007 · N653UA · Boeing 767322 · Equipment/Furnishings WiringSDR 2007UALA02506Switch · faultyEMERGENCY LIGHTING TEST SWITCH AT 1L AND 2R DOES NOT SWITCH ON FLOOR LIGHTING. [08-08-07] OPERATED EMERGENCY LIGHTING TEST SWITCH AT 1L AND 2R. OPS CK OK. CANNOT DUPLICATE PROBLEM. AIRCRAFT OK FOR SERVICE.Jul 7, 2007 · N654UA · Boeing 767322 · Emergency LightingSDR 2007UALA02509Feeder Cable · unsecureAFT GALLEY LONG EEL STRIP IS INOP. [07-27-07] SECURED FEEDER CABLE. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Light System WiringSDR 2007UALA02510Lamp · inoperativeAFT LEFT & AFT RIGHT DOOR EXTERNAL EEL LIGHTS ARE INOP. [07-27-07] RELAMPED. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Emergency LightingSDR 2007UALA02511Lamp · inoperativeLEFT SIDE EXTERNAL EEL LIGHT JUST AFT OF WING IS INOP. [07-27-07] RELAMPED. CHECKS GOOD.Jul 7, 2007 · N662UA · Boeing 767322 · Emergency LightingSDR 2007UALA02503Latch · bindingLEFT OVERWING SLIDE DOOR NR 2 LATCH BINDING. [08-08-07] REPLACED AND ADJUSTED LATCH PER MM25-65-98. DOOR 2 LATCH MOVES FREELY. SLIDE & AIRCRAFT OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SLIDE LATCHES EXPERIENCE FRETTING CAUSED BY VIBRATION & EXCESSIVE CLEJul 6, 2007 · N649UA · Boeing 767322 · Escape SlideSDR 2007UALA02504Floorbeam · corrodedFWD GALLEY FLOOR AREA, STA 246 AT RBL 72 AREA, BULKHEAD WALL, LOWER FLOOR CHORD CORRODED UNDER SHEAR WEBBING, FWD EDGE. REMOVED DAMAGED SECTION OF CHORD, RBL 49 TO RBL 72. FABRICATED & INSTALLED SPLICE & REPAIR ANGLES.Jul 6, 2007 · N649UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2007UALA02507Connector · unsecureEEL STRIP LIGHTS INOP AT SEATS 8HJ-10HJ. [07-27-07] SECURED CONNECTOR, OPS CK OK.Jul 6, 2007 · N661UA · Boeing 767322 · Light System WiringSDR 2007UALA02508Connector · unsecureEEL LIGHTS INOP AT SEATS 20HJ-23HJ. [07-27-07] SECURED CONNECTOR, OPS CK OK.Jul 6, 2007 · N661UA · Boeing 767322 · Light System WiringSDR HALA0700281Skin · bentPER INBD CREW, F/A REPORTS METAL STICKING UP ON NR 2 ENGINE. FOUND OUTBD FAN COWL TOP FWD CORNER DAMAGE APPROX 1-1/2" BY 1/2" AND FWD OUTBD. ON PYLON EXTENSION LIFTED APPROX 4" (APPROX 1/2" LIFTED UP). ACCOMPLISHED HAL-M105 FILE #597063 AND 597064. CONDITIJul 6, 2007 · N597HA · Boeing 767332 · Nacelle/Pylon, Plate/SkinSDR 2007UALA02440Light · inoperativeFOUND GALLEY MID LEFT & MID RIGHT EMERGENCY LIGHT STRIPS INOP. [07-27-07] REPLACED MID LEFT TOILET EMERGENCY LIGHT STRIP.Jul 5, 2007 · N654UA · Boeing 767322 · Emergency LightingSDR 2007UALA02389Light · disconnectedFLIGHT CANCELLED DUE TO FAILED EMERGENCY EXIT LIGHTS. [07-27-07] EMERGENCY LIGHT UNPLUGGED AT 27AB, TESTED EMERG LIGHT, 27AB SHOWS OKJul 4, 2007 · N654UA · Boeing 767322 · Emergency LightingSDR 2007UALA02354Power Cable · damagedFEEDER CABLE FOR RT LIGHT STRIP IS DAMAGED AND NEEDS REPLACED. REPAIRED POWER CABLE. OPS CHKS OK.Jul 1, 2007 · N643UA · Boeing 767322 · Light System WiringSDR 2007UALA02381Lens · inoperativeRED FIRE WARNING LIGHT DOES NOT ILLUMINATE WHEN TESTED. [07-27-07] REPLACED FIRE ANNUNICATOR LENS ASSY. OP CHECKS NORMALLY.Jul 1, 2007 · N657UA · Boeing 767322 · Fire DetectionSDR DL76L070840Engine · flamed outDIV DUE NR 2 ENGINE FLAME OUT. PERFORM FADEC BITE. FAULTS P5 LINE FAIL. REF ITEM 006. REMOVED AND REPLACED E FUEL PUMP AND FMU PER AMM. REF ITEM 005 FOR FUEL BOOST PUMP REPLACEMENT. PERFORM TEST 2, 3 AND 4 PER AMM 71-00-00 PG 501 ENG OPERATION AND ALL INJul 1, 2007 · N195DN · Boeing 767332 · Engine (Turbine/Turboprop)SDR 2007UALA02321Strip · looseFIRST CLASS EMERGENCY EVACUATION STRIP IS LOOSE. REPLACED POWER CABLE AND 2 EA ELEMENTS. OPS CHECKS OK.Jun 30, 2007 · N643UA · Boeing 767322 · Light System WiringSDR 2007UALA02352Power Cable · faultyLIGHT STRIP NR 5 INOP. REPAIRED POWER CABLE.Jun 30, 2007 · N643UA · Boeing 767322 · Light System WiringSDR 2007UALA02353Power Cable · damagedLIGHT STRIP NR 20 MOST FWD RT IS DAMAGED. REPLACED POWER CABLE.Jun 30, 2007 · N643UA · Boeing 767322 · Light System WiringSDR DL76L070838Unknown · unknownAPU FAULT AND SHUTDOWN ON ENGINE START. BITE CHECK OF APU ECU SHOWS NO FAULTS, APU SHUTDOWN OCCURRED ON ENGINE START WITH AIR DEMAND. FWD APU PNEU TO MCO PER MEL49-11-01C. ECU SHOWS NO FAULTS. REPLACED SCV AS PREVENTIVE MEASURE PE M/M. MOTORED ENG 2 TIMES Jun 30, 2007 · N1200K · Boeing 767332 · Airborne Auxiliary Power Unit (APU) SystemSDR 2007UALA02282Fan · faultyAFT EQ EXH FAN 2 STATUS MSG AFTER AIRCRAFT PWR UP. SOME HOT SMELLING ODOR. REPLACED EXHAUST FAN PER MM 21-26-01. ODOR GONE AND OP CHECKS OK.Jun 28, 2007 · N662UA · Boeing 767322 · Air Distribution FanSDR HALA0700269Circuit Card · malfunctionedETOPS SIGNIFICANT SYSTEM, RT ENG OVHT LOOP 1 STATUS MSG. T/S PER FIM 26-11-00 SWAPPED LT AND RT AFOLTS CARDS MSG FOLLOW CARD. RTN GOOD CARD TO ORIGINAL POS. REPLACED RT ENG CARD M689 MSG CLEARED. FIRE AND OVHT FOR LT AND RT ENG TEST NORMAL.Jun 27, 2007 · N586HA · Boeing 7673G5 · Overheat DetectionSDR DL76L070842Engine · malfunctionedAPU SHUTDOWN DURING ENG START. RESTARTED APU ELECT OK. REPLACED APU ASSY PER AMM. OP AND LK CKS GOOD. REMOVED MCO/PLAC.Jun 27, 2007 · N175DN · Boeing 767332 · APU Core EngineSDR 2007UALA02281Module · malfunctionedSMOKE REPORTED COMING FROM SEAT 5D UPON DEPLANING. COCKPIT CONFIRMED SMELL. FOUND VDB FAILED, SOME INTERNAL COMPONENTS OVERHEATED. NO OTHER DAMAGE TO WIRING OR OTHER COMPONENTS. REPLACED SEAT 5CD VIDEO DISTRIBUTION BOX. SYSTEM OP CHECKED OK.Jun 27, 2007 · N647UA · Boeing 767322 · Entertainment SystemSDR 2007UALA02265Sensor · out of adjustEMERGENCY DOORS LIGHT ILLUM WITH EICAS MSG POS 11 (05=L EMER DR , 06=R EMER DR, 11=L WING SLIDE, 12=R WING SLIDE). *S/D* FOUND SENSOR FOR DOOR CLOSED, S218 OUT OF ADJUSTMENT. SHIMMED AND ADJUSTED SENSOR PER MM 52-71-00. REACTIVATED DOOR PER MM 25-65-00. OJun 26, 2007 · N642UA · Boeing 767322 · Door Warning SystemSDR 2007UALA02266Wire · crossedSPINNING NR 8 ANTISKID TRANSDUCER CAUSES THE NR 3 WHEEL BRAKE TO RELEASE, SHOULD RELEASE NR 4. STOPPING THE NR 8 TRANSDUCER CAUSES NR 7 BRAKE TO RELEASE, SHOULD RELEASE NR 8. FOUND WIRES TO TRANSDUCER CROSSED BETWEEN TRANSDUCER NR 7 AND NR 8. REINSTALLED WIJun 26, 2007 · N658UA · Boeing 767322 · Landing Gear System WiringSDR HALA0700264Seal · leakingETOPS SIGNIFICANT SYSTEM - PER TECH SERVICE TSI "NR 2 ENG OIL CONSUMPTION" ADDED 6 PINTS TO NR 2 ENGINE. ACCOMPLISHED FIM 71-05-00 FIG 106 STEPS 1 AND 2 FOUND OIL COMING OUT (DURING DRY MOTOR) OF "OIL SEAL DRAIN FOR THE EEC ALTERNATOR DRIVE". REMOVED AND REJun 24, 2007 · N590HA · Boeing 7673CB · Turbine Engine Oil SystemSDR 2007UALA02210Floorbeam · gougedFWD PIT CARGO FLOORBEAM FRAME WEB HAS GOUGES ON FWD FRAME AT STA 654 AND LBL29. REMOVED DAMAGED SECTION OF WEB. FABRICATED AND INSTALLED A REPAIR DOUBLER.Jun 24, 2007 · N648UA · Boeing 767322 · Fuselage Main, Floor BeamSDR 2007UALA02209Access Panel · crackedNR 2 PYLON FWD OF ACCESS PNL NR 442BR WEB FWD OF FUEL FEED LINE IS CRACKED. INSTALLED DOUBLER REPAIR.Jun 22, 2007 · N648UA · Boeing 767322 · Nacelle/Pylon, Plate/SkinSDR 2007UALA02168Connector · disconnectedEEL LIGHT RT AISLE TORN LOOSE AT BUSINESS CLASS GALLEY. FOUND CONNECTORS DISCONNECTED AND TRANSPARENT COVER APPR 8 INCHES TOO SHORT. RECONNECTED PLUGS, APPLIED INTERIM REPAIR TO PROTECT. REPAIR DOES NOT OBSTRUCT LIGHTED PORTION OF STRIP. NEEDS TRANSPARENT Jun 21, 2007 · N646UA · Boeing 767322 · Light System WiringSDR 2007UALA02141Control Valve · malfunctionedAPU SHUT DOWN ON START, ATTEMPTED 2 STARTS, BOTH FAILED WITH FAULT INDICATION. [07-20-07] REPLACED APU SURGE CONTROL VALVE PER MM 49-53-01-401. ACCOMPLISHED MAIN ENG START PER JRH. OP CHECKS SATISFACTORY.Jun 20, 2007 · N646UA · Boeing 767322 · APU Core EngineSDR 2007UALA02155Wire · pinchedMAIN CABIN EMERGENCY EXIT LIGHT WIRES ARE PINCHED. REPAIRED PINCHED WIRES TO L977 AT STA 857, LBL 85 PER WDM 33-51-14 AND BSWPM 20-10-13. OPS TESTS GOOD PER MM 33-51-01 ON NON ROUTINE E2116I.Jun 20, 2007 · N648UA · Boeing 767322 · Light System WiringSDR HALA0700260Wire · shortedETOPS SIGNIFICANT SYSTEM, R ENG SHUTDOWN DID NOT DISPLAY AND AURAL WARNING AND APPROPRIATE ENGINE RELATED MESSAGES WERE NOT INHIBITED WITH ENG SHUTDOWN. REMOVED AND REPLACED RT ENGINE FUEL METERING UNIT PER AMM 73-21-01, CONDITION SAME FOUND CONNECTOR WIRES SJun 19, 2007 · N593HA · Boeing 76733A · Engine Fuel System WiringSDR DL76L070751Engine · making metalMETAL ON MASTER CHIP DETECTOR. REPLACED ENGINE PER ROUTINE TRANSMITTAL, RC CARDS 28-30.Jun 19, 2007 · N196DN · Boeing 767332 · Engine (Turbine/Turboprop)SDR DL757070752Wire Harness · shortedFWD GALLEY OVEN SPARKED SMOKED AND POPPED CIRCUIT BREAKER. FOUND TWO WIRES SHORTED ON OVEN WIRING HARNESS, REPAIRED WIRES. OPS NORMAL.Jun 19, 2007 · N900PC · Boeing 75726D · Equipment/Furnishings WiringSDR 2007UALA02143Computer · no testNO LAND THREE DISPLAYED NO MALFUNCTION NOTED. [07-20-07] MCDP CODE "SLAT SW-FCC L", ACP MM 22-00-03 & CAT III CHK PER MM 22-10-00, THRUST MANAGEMENT COMPUTER FAILED TEST. RPL TMC PER MM 22-31-01, OP CK GOOD. AC REMAINS IN CAT III STATUS .Jun 19, 2007 · N662UA · Boeing 767322 · Autopilot SystemSDR 2007UALA02044Unknown · odorCREW REPORTS ELECTRICAL BURNING ODOR EMANATING FROM AFT GALLEY AREA. [07-20-07] SUSPECT GALLEY HI-TECH FOODCART TO BE ODOR SOURCE PULLED AFT GALLEY LEFT CIRCUIT BREAKER U7 AND AFT GALLEY RIGHT CB U34 ON PANEL P11 TO ISOLATE POWER. RESET CBS U7 AND U34 0NJun 18, 2007 · N662UA · Boeing 767322 · Buffet/Galleys
Back to Pratt & Whitney PW4060