JASC 5315
Service difficulty reports · 44,223
Reports filed under 5315 · Fuselage Main, Floor Beam, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5315' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ABXA020163Splice · crackedBULKHEAD 965 CABIN FLOOR, LOWER FITTING WAS CRACKED AT LEFT BUTT LINE 33. REPLACED FITTING IAW DC-9 SRM 51-30-5.SDR AWXA200200627Seat Track · corrodedMCN - MAJOR REPAIR - DURING C-12 CHECK CORROSION WAS FOUND ON THE SEAT TRACK BETWEEN BS 324 TO 344, RBL 45, WL 208. MAINTENANCE CUTOUT DAMAGED SECTION OF SEAT TRACK, FABRICATED A NEW SECTION OF SEAT TRACK, A RADIUS FILLER, AND A FILLER. INSTALLED REPAIR PARTSSDR F3LA200200182Floorbeam · corrodedDURING C-2 CHECK, INSPECTION REPORTED CORROSION ON TOP OF FLOORBEAM AT STA 987.5, RBL 36 TO RBL 40. REPLACED FLOORBEAM PER SRM 53-10-9, FIG 3.SDR F3LA200200181Floorbeam · corrodedDURING C-2 CHECK, INSPECTION REPORTED CORROSION ON TOP OF FLOORBEAM AT STA. 947.5, RBL 38 TO RBL 43.75. REPAIRED FLOOR BEAM PER SRM 53-10-9.SDR COOSDR020198Floorbeam · corrodedMAIN CARGO CABIN BS 1130 LOWER CHORD CORRODED.SDR F3LA200200186Floorbeam · corrodedDURING C-2 CHECK, INSPECTION REPORTED CORROSION ON TOP OF FLOOR BEAM AT STA. 947.5, RBL 38. REPAIRED FLOOR BEAM PER SRM 53-10-9.SDR UPS02M39083Floorbeam · corrodedINSPECTION TYPE:C, AFT CARGO CORROSION ON FLOORBEAM UPPER CHORD AT STA 1902 0-20 RBL. CORROSION TRIMMED OUT IAW SRM 53-00-01 FIG 9. HFEC INSPECTION CARRIED OUT, NO CRACKS FOUND ON TRIMMED AREA. REPAIR ANGLE & FILLER, FAB & INSTALLED IAW SRM 53-00-01 VOL I &SDR AWXA200200605Floorbeam · corrodedDURING C-11 CHECK CORROSION WAS FOUND ON FLOORBEAM NUTPLATE HOLE AT BS 1340 RT, JUST INBOARD OF THE R-3 DOOR. MAINTENANCE REMOVED INBOARD CHORD RT FROM BS 1300 TO BS 1400, FABRICATED NEW REPAIR CHORD, AND INSTALLED REPAIR IAW B757-200 SRM 53-60-13.SDR 2002UALA01108Floorbeam · corrodedFORWARD CABIN FLOOR T-CAP BODY STATION 324 RBL 59-61 HAS SURFACE CORROSION. MAJOR REPAIR ACCOMPLISHED. CUT OUT FILLER AND ANGLE, INSTALLED FOR T-ANGLE REPAIR.SDR 2002UALA01107Floorbeam · corrodedCABIN FLOORBEAM HAD EXCESS CORROSION AT STATION 740 RBL 62 STRINGER 17L, ALSO GUTTER UNDER STRUCTURE L-CHANNEL WAS CORRODED STATION 740, 62 RBL. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW SECTION OF INNER CREASE BEAM FROM 664 TO 756. A NEW UNDER GUTTER L-CHANSDR 2002UALA01105Floorbeam · corrodedCABIN FLOOR BODY STATION 324 FLOORBEAM CAP AT RBL 41 TO RBL 43 HAS SURFACE CORROSION DAMAGE. MAJOR REPAIR ACCOMPLISHED. CUT OUT, FILLER AND ANGLE INSTALLED.SDR 2002UALA01104Floorbeam · corrodedCABIN FLOORBEAM BODY STATION 310 FLOORBEAM HAS EXCESSIVE MATERIAL LOSS DUE TO CORROSION AT RBL 42 UPPER SURFACE T-CAP. MAJOR REPAIR ACCOMPLISHED. CUT OUT FILLER AND REINFORCE ANGLES.SDR SIMA200218405Floorbeam · corrodedABI - MAINTENANCE FOUND CORROSION ON FORWARD DIGITAL. REMOVED CORROSION BY CUT OUT. FABRICATED A REPLACEMENT STRAP AND TWO DOUBLERS. REPAIR DONE IAW EMB 145 SRM 145/1142, CHAPTER 53, REV 18 53-21-10, AND STANDARD SRM PRACTICES. (M)SDR SIMA200218402Floorbeam · corrodedABI - MAINTENANCE FOUND CORROSION ON GALLEY CENTER FLOORBEAM. REMOVED CORRODED GALLEY CENTER BEAM. INSTALLED SERVICEABLE BEAM IAW EMB 145 SRM 145/1142, CHAPTER 51, REV 18 51-40-02, AEA ETN EM-53-028 R1, AND STANDARD SRM PRACTICES. (M)SDR 2002UALA01092Floorbeam · corrodedCABIN FLOOR BODY STATION 365 T-CAP IS CORRODED FROM BL 0 TO RBL 62. MAJOR REPAIR ACCOMPLISHED. REPLACED T-CAP.SDR AWXA200200639Floorbeam · corrodedLCQ - MAJOR REPAIR - DURING C-11 CHECK CORROSION WAS FOUND ON CABIN FLOORBEAM AT BS 1640, LBL 25 TO LBL 35. MAINTENANCE REMOVED DAMAGED SECTION OF FLOORBEAM BS 1640, FABRICATED 2 EACH REPAIR ANGLES, 2 EACH STRAPS, AND A CHORD, AND INSTALLED REPAIR PARTS IAW B7SDR AWXA200200603Floorbeam · corrodedDURING C-11 CHECK EXFOILIATION CORROSION WAS FOUND ON THE LOWER SIDE OF FLOORBEAM UPPER CHORD BETWEEN THE BEAM AND NUTPLATE BRACKET, BS 1680, RBL 15 - 20. REMOVED DAMAGED SECTION OF FLOORBEAM UPPER CHORD, FABRICATED 2 EACH REPAIR ANGLES AND 2 EACH STRAPS, AND SDR AWXA200200602Floorbeam · crackedDURING C-18 CHECK A 3/4 INCH CRACK WAS FOUND ON THE UPPER T-CHORD AT BS 727B, RBL 25. MAINTENANCE TRIMED OUT CRACKED AREA OF UPPER T-CHORD AT BS 727B, RBL 25. PERFORMED A HFEC INSPECTION TO VERIFY NO CRACKS EXIST. FABRICATED 2 EACH STRAPS, A FILLER, AND A SHIMSDR GTIA020824Floorbeam · damagedFTW - FOUND FORWARD CARGO COMPARTMENT CHAFING/DAMAGE AT FLOORBEAM STATION 408. FOUND AREA TO BE OUT OF LIMITS. FABRICATED REPAIR ANGLE. INSTALLED REPAIR PARTS. (M)SDR GTIA020823Floorbeam · damagedFTW - FORWARD CARGO COMPARTMENT HAS CHAFING/DAMAGE AT FLOORBEAM STATION 389. MATERIAL LOSS OUT OF LIMITS. FABRICATED DOUBLERS. INSTALLED DOUBLERS STATION 389. (M)SDR GTIA020822Floorbeam · damagedFTW - AFT PIT FLOORBEAM HAS CHAFING/DAMAGE THROUGH HOLE STATION 1174. FABRICATED ANGLE REPAIR AND FILLER. INSTALLED ANGLE AND SHIM. (M)SDR GTIA020821Floorbeam · damagedFTW - MID PIT FLOORBEAM HAS CHAFING/DAMAGE STATION 655. MATERIAL LOSS OUT OF LIMITS. FORMED ANGLES. INSTALLED ANGLES. (M)SDR AWXA200200600Web · crackedMCN - MAJOR REPAIR - DURING C-18 CHECK A 2" CRACK WAS FOUND ON CABIN FLOOR BEAM VERTICAL WEB BS 706, RBL 25. MAINTENANCE CUTOUT CRACKED AREA OF WEB AT BS 706, RBL 25. PERFORMED HFEC INSPECTION TO VERIFY NO CRACKS EXIST. FABRICATED A REPAIR DOUBLER AND WEB; INSSDR SWAA021399Floorbeam · corrodedDURING SCHEDULED D CHECK, FOUND FLOORBEAM CORRODED AT BS 986, WL 208 AND LBL 17. REPAIRED FLOORBEAM PER SWA RA.SDR SIMA200218101Floorbeam · corrodedDURING AN IMBV INSPECTION FOUND CORROSION ON GALLEY CENTER FLOOR BEAM. REMOVED CORRODED GALLEY CENTER BEAM. INSTALLED NEW FLOOR BEAM IAW SRM AND STANDARD SRM PRACTICES.SDR SIMA200217703Floorbeam · corrodedDURING IMBV INSPECTION FOUND CORROSION ON GALLEY RIGHT HAND FLOORBEAM. REMOVED CORRODED GALLEY RT BEAM. INSTALLED NEW BEAM IAW STANDARD SRM PRACTICES.SDR C2XA02SH020Floorbeam · corrodedSHV - DURING C-CHECK INSPECTION, THE CENTER OMEGA BEAM AT FRAME 59 WAS FOUND TO BE CORRODED AROUND A NUT PLATE. MAINTENANCE REMOVED THE CORROSION AND INSTALLED A DOUBLER REPAIR IN ACCORDANCE WITH CONTINENTAL EXPRESS ENGINEERING CHANGE AND REPAIR AUTHORIZATIONSDR C2XA02SH019Floorbeam · corrodedSHV - DURING C-CHECK INSPECTION, THE RT OUTBOARD OMEGA BEAM AT FRAME 55 WAS FOUND TO BE CORRODED AROUND A SCREW HOLE. MAINTENANCE REMOVED THE CORRODED SECTION AND INSTALLED A DOUBLER REPAIR IN ACCORDANCE WITH CONTINENTAL EXPRESS ENGINEERING CHANGE AND REPAIR SDR SIMA200217705Floorbeam · corrodedDURING IMBV INSPECTION, FOUND CORROSION ON FORWARD DIGITAL REMOVED CORROSION BY CUT OUT. FABRICATED A REPLACEMENT STRAP, TWO DOUBLERS. REPAIR DONE IAW STANDARD SRM PRACTICES.SDR MALA020397Floorbeam · corrodedDURING C-CHECK IN CVG, CORROSION FOUND ON THE FLOORBEAM AT FRAME 15, 10 INCHES INBOARD FROM THE LT SIDE. MAINTENANCE REPAIRED DAMAGE INBOARD FROM THE LT SIDE. DAMAGE REPAIRED IAW BAE APPROVED FAX/BARA/AVR/5966/02-DC AND EO A53087.SDR 2002UALA01061Floorbeam · damagedCABIN FLOORBEAM BODY STATION 295 RBL 31 TO RBL 44 UPPER SURFACE HAS EXCESS MATERIAL LOSS. MAJOR REPAIR ACCOMPLISHED. FLOORBEAM UPPER CAP SPLICE REPAIR.SDR C2XA02SH017Floorbeam · corrodedSHV - DURING C-CK INSPECTION, THE LEFT HAND OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 24 & 25. MAINTENANCE REMOVED THE DAMAGED SECTION OF THE OMEGA BEAM AND INSTALLED A REPAIR DOUBLER IN ACCORDANCE WITH EMB-145 SRM 53-21-10, AND THE AIRCRAFT WAS APPRSDR C2XA02SH016Floorbeam · corrodedSHV - DURING C-CHECK INSPECTION, THE CENTER OMEGA BEAM WAS FOUND TO BE CORRODED BETWEEN FRAMES 24 AND 25. MAINTENANCE REMOVED THE DAMAGED SECTION OF OMEGA BEAM AND INSTALLED A REPAIR DOUBLER IN ACCORDANCE WITH EMB-145 SRM 53-22-10, AND THE AIRCRAFT WAS APPROVSDR SWAA021388Floorbeam · corrodedDURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM CORRODED AT BS 859, LBL 13 AND LBL 8. REPAIRED FLOORBEAM PER SWA RA.SDR 02FDEA00429Floorbeam · corrodedCORROSION ON FLOORBEAM AT BS 890, LBL 50-52, WL 201 AFT SIDE OF LWR FLANGE UPPER SIDE.SDR UPS02238813Floorbeam · corrodedINSPECTION TYPE:C+SI LIGHT SURFACE CORROSION FOUND ON TOP CAP OF FLOORBEAM AT BS 344 BETWEEN LBL 4 TO RBL 30. CORROSION BLENDED BETWEEN LBL 4 AND RBL 30, FOUND TO BE OUTSIDE LIMITS. REPLACED TOP CAP OF FLOORBEAM AT BS 344 IAW DWG 65-16316 AND SRM 51-30-2.SDR SIMA200217707Floorbeam · corrodedDURING IMBV INSPECTION FOUND CORROSION ON LEFT HAND BEAM AT FRAME 20. REMOVED CORROSION BY CUT OUT. FABRICATED A DOUBLER ANGLE, PLATE, FILLER, AND SHIMS. REPAIR DONE IAW AND STANDARD SRM PRACTICES.SDR UPS02238790Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON UNDER SIDE OF FLOORBEAM TOP CAP BS 560 LBL12. REPAIRED IAW SRM 53-10-8 FIGURE 5 .SDR UPS02238789Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON TOP OF FLOOR BEAM BS 560 LBL 40. REPAIR CARRIED OUT IAW SRM 53-10-08 FIGURE 5SDR UPS02238788Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON TOP OF FLOORBEAM BS 540 LBL12. REPAIRED IAW SRM 53-10-8 FIGURE 5SDR UPS02238762Floorbeam · corrodedINSPECTION TYPE:C+SI LIGHT SURFACE CORROSION AROUND ANCHOR NUT AT BS 480 LBL 8 FLOORBEAM. CORROSION REMOVED AND FOUND OUTSIDE ALLOWABLE LIMITS OF SRM53-10-1 FIG 5.SDR 2002UALA01056Floorbeam · corrodedCABIN FLOORBEAM STA 365 RBL 18 MATERIAL REMOVED BEYOND LIMITS. MAJOR REPAIR ACCOMPLISHED. CABIN FLOORBEAM UPPER CAP REPLACED.SDR 2002UALA01052Floorbeam · corrodedSTATION 986 CABIN FLOORBEAM TOP CAP IS CORRODED FROM CENTER LINE TO RBL 42 IN SEVERAL AREAS. MAJOR REPAIR ACCOMPLISHED. INSTALLED NEW T-CAP AND DOUBLER.SDR UPS02M38949Floorbeam · corrodedINSPECTION TYPE:C, CTR CARGO STA 1841, BL 0 - RBL 60 FLOORBEAM WEB FOUND CORRODED. FLOORBEAM WEB REMOVED AND REPLACED AS PER DWG AGA7170 AND INSTALLED AS PER SRM 51-35-01 VOL II REV 31.SDR ABXA020044Floorbeam · crackedFLOORBEAM SUPPORT CRACKED AT LOWER END, FS 617 AND LONGERON 23L. REPAIRED FLOOR BEAM SUPPORT IAW DC-9 SRM 51-30-2 AND 51-30-5.SDR CALA0200356Floorbeam · corrodedINSPECTION FOUND FLOORBEAM CORRODED UNDER NUTPLATES AT FS 1338, RBL 58 TO LBL 58. THE UPPER FLOORBEAM CAP WAS REMOVED AND REPLACED IAW SRM 51-30-2 AND 51-30-5.SDR UPS02238791Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON FLOORBEAM LOWER CHORD BS 1030 LBL 52. REPAIRED IAW BOEING INSTRUCTIONS SRV-SNN-02-00112H AND 00132H B727-53-20058SDR UPS02238749Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON FLOORBEAM WEB AFT SURFACE AT BS890 RBL 34, CORROSION REMOVED IAW 51-10-6 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-1.SDR UPS02238748Floorbeam · corrodedINSPECTION TYPE:C+SI CORROSION ON FLOORBEAM WEB AFT SURFACE AT BS 890 RBL25. CORROSION REMOVED AND FOUND TO BE WITHIN LIMITS IAW 51-10-6SDR C2XA02SH018Floorbeam · corrodedSHV - DURING C-CHECK INSPECTION, THE LEFT HAND INBOARD OMEGA BEAM LOWER FLANGE WAS FOUND TO BE CORRODED BETWEEN FRAMES 22 & 23. MAINTENANCE REMOVED THE DAMAGED SECTION OF FLANGE AND PERFORMED A DOUBLER REPAIR IN ACCORDANCE WITH CONTINENTAL EXPRESS ENGINEERING
Back to JASC 5315