JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023071005519Channel · corroded(LOG 2851984) CORROSION FWD CARGO BAY R/H ZEE CHANNEL HAS MULTIPLE LOCATIONS OF CORROSION FROM STA 500C TO 500L. REMOVED AND REPLACED FWD CARGO BAY ZEE CHANNEL FROM STA 500A TO 500L R/H, PERFORMING A REPAIR SLICE AT STA 500E+12 IAW B737 SRM 53-00-53-2R, SRM 51SDR DALA2023070705504Unknown · unknownSHIP 3118 CRACK FLOOR STRUCTURE WEB LOCATED BTW FR 8 TO FR 11 AND Y765 IN COCKPIT. CORRECTIVE ACTION: REPLACED WEB LOCATED FLOOR STRUCTURE BTW FR 8 TO FR 11 AND Y765 IN COCKPIT AS PER A319 SRM 51-72-11. (2852283)SDR DALA2023070705503Unknown · unknownSHIP 3118 CRACK FLOOR STRUCTURE WEB LOCATED BTW FR8 TO FR11 AND -Y 765 IN COCKPIT. CORRECTIVE ACTION: REPLACED WEB LOC FLOOR STRUCTURE BTW FR 8 TO FR 11 AND -Y765 IN COCKPIT AS PER A319 SRM 51-72-11. (2852280)SDR DALA2023070705501Unknown · unknownSHIP 3118 CRACK SUPPORT STRUCTURE LOCATED BTW FR 21 TO FR 23 AND STR 43L TO STR 43R IN AFT AVIONIC COMPARTMENT. CORRECTIVE ACTION: REPLACED SUPPORT STRUCTURE LOCATED BTW FR 21 TO FR 23 AND STR 43L TO STR 43R IN AFT AVIONIC COMPARTMENT AS PER A319 SRM 51-42-11.SDR CALA2023070702188Flange · corrodedFR68 R-2 DOOR SILL FLANGE CORRODED AT FASTENER HOLES. (A3NB-53-3 -6222). GENERATED BY V892285 AT HAECO LCQ PER NR 9290187 (30187) . REPAIRED R-2 DOOR SILL FLANGE IAW A319 SRM 53-41-14-300-001. PER FORMED BY V061732.SDR SWI2023F00313Unknown · corrodedDATUM 2 INTERCOSTAL BETWEEN APPROX FS338 - FS347 HAS CORROSION (C-CHECK RO 9/6/2023) REMOVED AND REPLACED INTERCOSTAL D2 BETWEEN FS338 - FS347 REF CRJ200 SRM 51-42-06 , AND DWG 601R31702 REV-N. COMPLIED WITH 51-900-1003-SKY AND PRESSURE CHECK GOODS . SESDR SWI2023F00311Unknown · corrodedDATUM 3 INTERCOSTAL BETWEEN APPROX FS320 - FS338 HAS CORROSION (C-CHECK RO 9/6/2023) REMOVED AND INSTALLED NEW PAX DOOR DATUM 3 INTERCOSTAL BETWEEN FS 320 -FS338 REF CRJ-200-SRM 51-42-06, CRJ-200-SRM 51-42-21 AND DRAWING 601R31702 REV N . COMPLIEDWITH 5SDR SWI2023F00309Unknown · corrodedDATUM 4 INTERCOSTAL BETWEEN APPROX FS338 - FS347 HAS CORROSION (C-CHECK RO 9/6/2023) REMOVED AND REPLACED INTERCOSTAL D4 BETWEEN FS338 - FS347 REF CRJ200 SRM 51-42-06 DWG 601R31702 REV-N. COMPLIED WITH 51-900-1003-SKY AND PRESSURE CHECK GOOD . SEE CONTISDR SWI2023F00308Unknown · corrodedDATUM 1 INTERCOSTAL BETWEEN APPROX FS338 - FS347 HAS CORROSION (C-CHECK RO 9/6/2023) REPLACED INTERCOSTAL D1 BETWEEN FS338 - FS347 REF CRJ200 SRM 51-42-06. DWG 601R31702 REV-N. PRESSURE LEAK CHECK GOOD. SEE CONTINUE CARD FOR ALL WORK PERFORMED. COMPLIESDR SWAA2023082975546Sidewall Support · corrodedCORROSION AFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS AROUND NUT PLATE HOLES BS727C+19' TO BS767 RBL22 WL156<[01] CORROSION DAMAGE ON ACB R/H FLOOR TO SIDEWALL SUPPORT PLATE BS727C+19' TO BS767; RBL22;WL156 WAS FOUND TO BE OUT OF LIMITSDR SWAA2023082975542Sidewall Support · corrodedCORROSION AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE MULTIPLE AREAS AROUND NUT PLATE HOLES BS727D+10 TO BS787+5 LBL22 WL156<[01] VERIFIED MEASUREMENT TABLE.;[02] REPAIRED ACB LH FLOOR TO SIDEWALL SUPPORT; BS 727C+10 TO 787+12; AND INSTALLED REPAIR PARTSSDR SWAA2023082975543Shield · corrodedCORROSION AFT CARGO BAY SHIELD AFT OF CARGO DOOR HAS MULTIPLE AREAS AROUND NUT PLATE HOLES BS847 TO BS867 RBL22 WL163.5<[01] UPDATED MEASUREMENT TABLE.;[02] COMPLETED STEP 1;[03] COMPLETED STEP 4 <BR>VERIFIED MEASUREMENT TABLE.;[04] VERIFIED MEASUREMENT TABLE.SDR SWAA2023082975544Shield · corrodedCORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767+3 TO BS794 RBL22 WL156<[01] REMOVED AND REPLACED ACB SHIELD FWD OF CARGO DOOR BS 767 TO BS 787+6; RBL 22; WL 156 IAW SRM 51-40-02-0G-0; SRM 51-40-05; DWG#146A0081.;[02] VERISDR SWAA2023082975548Shield · corrodedCORROSION FWD CARGO BAY AFT SHIELD BS500+1 TO BS500+19 RBL22 WL156 HAS MULTIPLE AREAS AROUND NUT PLATE HOLES<[01] VERIFIED STEPS 4 AND 5.;[02] CORROSION ON FWD CARGO BAY AFT SHIELD BS500+1? TO BS500+19? RBL22 WL156 FOUND TO BE OUT OF LIMITS. REMOVED AND REPLACSDR SWAA2023080475386Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION 2023-431107<[01] INSTALLED NEW INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM SDR SWAA2023080475382Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION 2023-431108<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND SRM 51-10-SDR SWAA2023080475393Intercostal · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW RBL 24.75 TO RBL 45.5 AT CENTER SECTION 2023-431113<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW RBL 24.75 TO RBL 45.5 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-0SDR SWAA2023080475394Angle · crackedCRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 RBL 24.75 CENTER SECTION 2023-431116<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112811019; DUE DATE: 25-JAN-24 AND SDR SWAA2023080475381Floor Support · crackedCRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER 2023-431106<[01] OPEN FAULT HAS AN ERROR AND IS BEING CORRECTED BY RAISING A NEW FAULT; SEE TTG8Q00M1CBD;[02] TASK CARD COMPLETED <BR>FAULT HAS AN ERROR AND IS BEING CORRECTED SDR AALA202307184439Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON FORWARD CARGO COMPARTMENT LEFT HAND TRANSITION PANEL LOCATED FROM BS 500I PLUS 10 INCHES TO BS 500H AT LBL 33. REPLACED TRANSITION PANEL PER SRM 53-00-53-2R-5 AND DWG DBF2137 AND AARD 51-00-05-1.SDR CALA2023070702184Intercostal · crackedB737-53-3-0736 MAIN CABIN FLOOR HAS CRACKED INTERCOSTAL AT BS 31 2-325 RBL 32 REMOVED AND INSTALLED INTERCOSTAL FLOOR MAIN CABIN BS 312-328 RB L 32 IAW B737-900 ER SRM 51-40-02-06-0. DATA WAS TRANSCRIBED FRO M PAPER DOC AERSALE 3953 OPS 33275 WORK ACP BY MECH SDR DALA2023070605475Unknown · unknownSHIP 0687 CORROSION ON INTERCOSTALS BTW STA 720-740 BL=35RH WAS FOUND OUT OF LIMITS. CORRECTIVE ACTION: INTERCOSTAL BTW STA 720 -740 BL=35RH WAS REPLACED PER B757-200 SRM 51-40. (2849952)SDR REXA2022070600450Angle · corrodedPAX DOOR SILL ANGLE IS CORRODED ON IB & OB SIDE NEAR OR AT SEVERAL FASTENER HOLES AND AT LOWER FORWARD FLANGE. DOOR SILL ANGLE (KICKPLATE ANGLE) P/N SH670-31875-7 ON PAX DOOR SURROUND STRUCTURE, IAW CRJ900 SRM 51-42-06-001-001-A01 & 51-42-21-001-001-A01.SDR REXA2022070600449Angle · corrodedPAX DOOR SILL ANGLE IS CORRODED ON IB & OB SIDE NEAR OR AT SEVERAL FASTENER HOLES AND AT LOWER FORWARD FLANGE. AFTER REMOVED ANGLE, MID CAP FROM PAX DOOR SURROUND STRUCTURE FOUND CORRODED MORE THAN 30% OF A MEMBER, PART IS OUT OF LIMITS, IAW CRJ900 SRM 53-21-SDR REXA2022070600448Angle · corrodedLH FLOOR SILL ATTACHMENT ANGLE AT FS 693 IS CORRODED AROUND DRAIN TUBE. INSTALLED NEW ATTACHMENT ANGLE SERVICEABLE AT LH FLOOR SILL DRAIN TUBE FS 693 IAW CRJ900 SRM 51-42-06-001-001-A01.SDR DALA2023070605448Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM +Y2462 LOCATED FR31 TO FR37 LH SIDE IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM Y2462 AND FASTENERS LOC BTW FR 26/28 TO FR 37.4 IN PASSENGER CABIN. (2851015)SDR DALA2023070605447Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM -Y2462 LOC FR31 TO FR37 IN PASSENGER CABIN. CORRECTIVE ACTION: REPLACED FLOOR BEAM -Y2462 AND FASTENERS LOC BTW FR 26/28 TO FR 37.4 IN PASSENGER CABIN. (2851013)SDR DALA2023070605446Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM YB LOCATED FR71 TO FR73 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACE FLOOR BEAM YB LOC. FR71 TO FR73 AT AFT GALLERY AREA. (2851009)SDR DALA2023070605445Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM YB LOCATED FR73 TO FR74 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACE FLOOR BEAM YB LOC. FR73 TO FR74 AT AFT GALLERY AREA. (2851006)SDR DALA2023070605444Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM YB1 LOCATED FR73 TO FR74 AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM YB1 LOC. FR73 TO FR74 AT AFT GALLERY AREA. (2851003)SDR DALA2023070605442Unknown · unknownSHIP 3353 CORROSION FLOOR BEAM -YC1 LOCATED FR73 TO FR74 RH SIDE AT AFT GALLEY AREA. CORRECTIVE ACTION: REPLACED FLOOR BEAM -YC1 LOCATED FR73 TO FR74 RH SIDE AT AFT GALLEY AREA. (2850998)SDR DALA2023070605439Unknown · unknownCORROSION ON FLOOR SUPPORT BELOW ACCESORY COMPARMENT DOOR BTW LBL16 AND RBL16 STA 1053. SUMMARY OF NRC 00367: CORROSION LEVEL 2. FLOOR SUPPORT BELOW ACCESORY COMPARMENT DOOR BTW LBL16 AND RBL16 STA 1053 WAS REPAIRED PER PRI 609849-14 REV 0 AND REV 1 AND ERA 60SDR DALA2023070605438Unknown · unknownCORROSION ON FLOOR SUPPORTS BTW STA Y=197/158 AND LBL=54 AND FLOOR SUPPORTS STA Y=200 AND BTW RBL=44/54 AT PAX CABIN WERE FOUND OUT OF LIMITS (W1). SUMMARY OF NRC 00676: CORROSION LEVEL 2. FLOOR SUPPORTS BTW STA Y=197/158 AND LBL=54 AND FLOOR SUPPORTS STA Y=20SDR DALA2023070605437Unknown · unknownCORROSION ON FLOOR SUPPORTS STA Y=197 AND BTW LBL=15/43 WAS FOUND OUT LIMITS AT PAX CABIN (W1). SUMMARY OF NRC 00677: CORROSION LEVEL 2. FLOOR SUPPORT STA Y=197 BTW LBL=15/43 WAS FABRICATED AND REPLACED PER DWG 99365534 REV BW AND B717-200 SRM 51-41-02-0G AND SDR V0XD20230705002Gusset · corrodedCENTER LAV FLOOR GUSSET LOCATED AT FRM 59-61 SIGNS OF CORROSION. CORRECTIVE ACTION: REMOVED AND REPLACED DAMAGED FLOOR GUSSET (P/N:145-22226-003) IAW EMB 145 SRM 51-40-02SDR SWAA2023080974772Intercostal · crackedCRACKED INTERCOSTAL IN UPPER AFT RADIUS BS 947 RBL 17 WL 179<[01] VERIFIED APPLICABILITY OF SRM 53-70-53-01-2 IDENTIFICATION 2 - SECTION 47 AND SRM 53-00-53-1A-2 ALLOWABLE DAMAGE 2.;[02] VERIFIED ITEM 1 CORRECTIVE ACTIONS.;[03] MEASURED CRACK ON INTERCOSTAL ISSDR SWAA2023080974778Shield · corrodedFWD SHIELD IS CORRODED FROM BS 767-767+16 RBL 20 WL 157<[01] UPDATED MEASUREMENTS TABLE;[02] NOT FOUND ALLOWABLE ON SRM; PART WILL BE REPLACE PER SRM 51-10-02-0G-0; STEP 9;[03] REMOVED FWD SHIELD FROM AFT CARGO COMPARTMENT FROM BS 767 TO BS 794.25 IAW SRM 51-4SDR SWAA2023080974779Support · corrodedFLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727E+13 - 787+19 RBL 20 WL 156<[01] UPDATED MEASUREMENTS TABLE;[02] FOUND UNDER INVESTIGATION LOCATION IS BS 727E+13 TO BS 747+19; RBL 20; WL 156;[03] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS;[04] BLENDED CORROSION ONSDR SWAA2023080974771Strap · corrodedCORROSION ON THRESHOLD TIE STRAP AT FASTENER HOLES BS 787+8 - 807+13 RBL 20 WL 159<[01] VERIFIED APPLICABILITY IAW SRM 53-60-15-01-1 AND SRM 53-60-15-1A-1;[09] OK TO INSTALL NEW THRESHOLD TIE STRAP.;[10] OKAY TO INSTALL GIVEN.;[11] STARTED INSTALLATION OF THRESDR SWAA2023080974777Support · corrodedFLOOR TO SIDEWALL SUPPORT CORROSION BS 727A+9 - 767 RBL 20 WL 156<[01] UPDATE MEASUREMENTS TABLE;[02] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS;[03] BLENDED CORROSION ON FLOOR TO SIDEWALL SUPPORT CORROSION BS 727A+9 - 767 RBL 20 WL 156;<BR>WORK AREA <BR>BS 727ASDR SWAA2023071874658Scuff Plate · crackedAFT CARGO BAY AFT CORNER SCUFF PLATE IS CRACKED<[01] WELDED CRACK ON AFT CARGO BAY AFT CORNER SCUFF PLATE USING ER4043 ALUMINUM FILLER ROD LOT NUMBER 1131216 PER SRM 53-60-15-2R-1 PARAGRAPH 4. B. (2) AND (4). REPAIR AREA STILL REQUIRES A DYE PENETRANT INSPECTISDR FDEA202307041221Web · crackedMAIN DECK FLOOR STRUCTURE SHEAR WEB FOUND CRACK NEAR FR79 PLUS 5",Y1650 REPLACED THE CRACKED SHEAR WEB WITH NEW PART. I.A.W A300-600F SRM 51-72-10-001, PAGE2.SDR FDEA202307041220Web · crackedMAIN DECK FLOOR STRUCTURE SHEAR WEB FOUND CRACK NEAR FR79 PLUS 5", Y-1650 REPLACED THE CRACKED SHEAR WEB WITH NEW PART. I.A.W A300-600F SRM 51-72-10-001, PAGE2.SDR DALA2023070605473Unknown · unknownSHIP 0687 CORROSION ON INTERCOSTAL UPPER MATTING SURFACE STA 1650 BTW RBL 13 AT FLOOR STRUCTURE. CORRECTIVE ACTION: ANGLE (TEE) ON INTERCOSTAL STA 1650 BTW RBL 13 AT FLOOR STRUCTURE WAS REPLACED PER B 757-200 SRM 51-40. (2849285)SDR SWAA2023070674922Panel · crackedAFT CARGO PANEL 142DW HAS MULTIPLE CRACKS ALONG FLOOR.<[01] REMOVED AND REPLACED AFT CARGO PANEL 142DW REF AMM 50-10-02.SDR SWAA2023070674920Panel · crackedAFT CARGO PANEL 141FW HAS MULTIPLE CRACKS ALONG FLOOR.<[01] RAR AFT CARGO PANEL 141FW REF AMM 50-10-02.SDR SWAA2023070674923Panel · crackedAFT CARGO PANEL 141DW HAS MULTIPLE CRACKS ALONG FLOOR.<[01] RAR AFT CARGO PANEL 141DW REF AMM 52-10-02SDR SWAA2023070674924Panel · crackedAFT CARGO PANEL 141HW HAS MULTIPLE CRACKS ALONG FLOOR.<[01] RAR AFT CARGO PANEL 141HW REF AMM 52-10-02SDR SWAA2023070674921Panel · crackedAFT CARGO PANEL 142FW HAS MULTIPLE CRACKS ALONG FLOOR.<[01] REMOVED AND REPLACED AFT CARGO PANEL 142FW REF AMM 50-10-02.SDR DALA2023070505394Unknown · unknownCORROSION ON CUSP ANGLE (LWR SURFACE AREA) BTW STA Y=200 AND X=55 TO X=60 AT PASSENGER CABIN FLOOR STRUCTURE. SUMMARY OF NRC 00633: CORROSION LEVEL 2. CUSP ANGLE (LWR SURFACE AREA) BTW STA Y=200 AND X=55 TO X=60 AT PASSENGER CABIN FLOOR STRUCTURE WAS REPAIRED
Back to JASC 5320