JASC 5320
Service difficulty reports · 216,207
Reports filed under 5320 · Fuselage Miscellaneous Structure, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DALA2023010308523Web · corrodedCORROSION ON WEB AT LWR SILL AREA BTW STA Y=946-954 PROJECTION LONG 28R-29R OF AFT CARGO COMPARTMENT. CORROSION LEVEL 2. WEB AT LWR SILL AREA BTW STA 946 TO STA 1002 PROJECTION LONG 28R-29R OF AFT CARGO WAS REPLACED IAW SRM 51-41-01-0G, SRM 51-41-02-0G PAR 4,SDR CALA2023010200001Floor Support · corrodedMAIN CABIN FLOOR STRUCTURE. R/H FR 66 OTBD BEAM CORRODED 3 PLACE S. () REPLACED FLOOR BEAM AT MAIN CABIN FLOOR STRUCTURE RH BTW FR65 AND FR66 IAW SRM 51-42-11 AND SRM 51-72-11 EMP#: WORK ACCOMPLISHED AT ST ENGINEERING O F MOBILE AT BFM ON NR#: 48056SDR VNAA202212300001Angle · crackedWHILE PERFORMING SB670BA-53-040 VISUALLY FOUND CRACK ON STR 3L AT FS 280 FIRST 2 HOLES. PERFORM REO 670-53-21-493 REV -D DATED 2015-07-10SDR AALA202302216171Transition Panel · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT RIGHT HAND TRANSITION PANEL LOCATED BETWEEN BS 877 AND BS 885 AT RBL 26. REPLACED TRANSITION PANEL PER SRM 51-40-02-0G AND AARD 51-00-05-1.SDR AALA202302213737Strap · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT DOOR CHORD ATTACH STRAP LOCATED AT BS 790 AND RBL 20. REPLACED STRAP PER SRM 51-40-02-0G.SDR AALA202302103343Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION FOUND ON HIGH FREQUENCY WIRING CONTAINMENT BOX. LOCATED AT STA 718 AND RIGHT BUTT LINE 30. REMOVED AND REPLACED BRACKET PER AARD.SDR AALA202302025155Bracket · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON RIGHT MAIN LANDING GEAR WHEEL WELL SHELF BRACKET, FORWARD OF HYDRAULIC SYSTEM B RESERVOIR, LOCATED AT BS 665 AND RBL 54. REPLACED BRACKET PER SRM 53-050-00.SDR SWAA2023020186281Sill Drain · corrodedCORROSION WATER DRAIN VALVE AFT SILL DRAIN BLADDER ASSEMBLY AT AFT GALLEY AREA (1 EA) 2022-695556<[01] REPLACED WATER DRAIN VALVE AFT SILL DRAIN BLADDER ASSEMBLY AT AFT GALLEY AREA (1 EA) IAW B737-700 AMM 38-31-03-400-802 AND AMM 38-31-03-000-802;[02] CORRECTESDR SWAA2023013186319Intercostal · crackedFWD WET AREA FLOOR SUPPORT INTERCOSTAL CRACKED @ UPPER CAP BL-0 BETWEEN STA 344 AND STA 360 MKD DOT<[01] INSTALLED EWIS.ON FAULT # TTG8Q003DV3A.;[02] REMOVED INTERCOASTAL AT FWD WET AREA STA 340 TO STA 360;BL 0.PER B 737-700 SRM 51-40-02-0G-0.;[03] VERIFIED STSDR SWAA2023013186320Structure · crackedFWD CABIN WET AREA INNER CHORD CRACKED @ LBL-50 STA 303.9 MKD DO 001<[01] PERFORMED HFEC INSP. ON SUSPECTED CRACK AT FWD CABIN WET AREA INNER CHORD LBL-50 STA 303.9 IAW B737 NDT PART 6; 51-00-00; PROCEDURE 23. CRACK CONFIRMED (CRACK LENGTH 1') <BR>TOOL: NORTECSDR SWAA2023013186317Structure · corrodedCORROSION @ L-1 DOOR LOWER SILL INNER CHORD FROM STA 312 TO STA 344 MKD DOT<[01] L-1 DOOR INNER CHORD FROM STA 277 THRU STA 370 WAS REPLACED ON FAULT #TTG8Q00GYPNH;[02] VRRIFIED STEP 1SDR SWAA2023012786250Stiffener · crackedCRACKED STIFFENER AT ACB BEHIND WATER SERVICE PANEL BS918 RBL11. MARKED.<[01] EVALUATED STIFFENER; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 AND THE MEASUREMENT TABLE.SDR SWAA2023012786218Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS727A+3 RBL3. MARKED.<[01] EVALUATED CORROSION ON INTERCOSTAL BS 727A+3 RBL 3 WL 148; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTIOSDR SWAA2023012786234Channel · corrodedCORROSION ON RAIL SPLICE AT AFT CARGO BAY BS767+6 RBL8.<[01] FOUND TO BE OUT OF LIMITS DUE TO CORROSION IS COMMON TO A PREVIOUS REPAIR.;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] NO REPAIR LIMITS FOUND ON SRM; REMOVED DAMAGE REINFORCING CHANNSDR SWAA2023012786225Intercostal · corrodedCORROSION ON INTERCOSTAL ATTACH TAB AT AFT CARGO BAY BS767+1; RBL22.<[01] EVALUATED CORROSION ON INTERCOSTAL ATTACH TAB BS 767+1 RBL 22 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CSDR SWAA2023012786226Shield · corrodedCORROSION ON FWD SHIELD AT AFT CARGO BAY BS767 - 787 RBL22.<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] REMOVED DAMAGED FWD SHIELD AT AFT CARGO BAY BSSDR SWAA2023012786227Angle · corrodedCORROSION ON FWD SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767+6 RBL21.<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] REMOVED DAMAGED SHIELD ATTACH ANGLE ATSDR SWAA2023012786235Angle · corrodedCORROSION ON ANGLE AT AFT CARGO BAY BS767+8 RBL18.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 767+8' REMOVED 0.010' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.063' FOUND TO BE OUT OF LIMITS PER SRM 53-00-04-1A-1 USING ATS TOOL ISDR SWAA2023012786228Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS787+1 RBL23.<[01] EVALUATED CORROSION IN INTERCOSTAL BS 787+1 RBL 23 WL 157; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 AND SDR SWAA2023012786236Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS767+9; RBL6.<[01] EVALUATED CORROSION ON INTERCOSTAL BS 767+9 RBL 6 WL 152; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 AND TSDR SWAA2023012786237Strap · corrodedCORROSION ON SUPPORT STRAP AT AFT CARGO BAY BS787+9 RBL20.<[01] EVALUATED CORROSION ON SUPPORT STRAP BS 787+9 RBL 20 WL 157; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 SDR SWAA2023012786242Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS807+13 RBL6.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 807+13' REMOVED 0.0006' IN AN AREA OF 1'X1' ORIGINAL THICKNESS 0.036' FOUND TO BE OUT OF LIMITS PER SRM 53-00-04-1A-1 USING ASDR SWAA2023012786246Shield · corrodedCORROSION ON AFT SHIELD AT AFT CARGO BAY BS847 - BS867 RBL21. MARKED.<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] LOCATED AND DRILLED NEW AFT SHIELD ASDR SWAA2023012786243Intercostal · corrodedCORROSION ON INTERCOSTAL AT AFT CARGO BAY BS847+5 RBL24.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 847+5' REMOVED 0.010' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.063' FOUND TO BE OUT OF LIMITS PER SRM 53-00-04-1A-1 USING ATS SDR SWAA2023012786247Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT ACB BS 867 - BS887 RBL21.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 887+10' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-SDR SWAA2023012786244Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT BS887 - BS847 RBL21.<[01] CORRECTION TO TASK DETAIL SHOULD STATE ' CORROSION ON FLOOR TO SIDEWALL SUPPORT BS887 - BS947 RBL21.;[02] VERIFIED ITEM 1 CORRECTIVE ACTIONS.;[03] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPSDR SWAA2023012786252Support · corrodedCORROSION ON BULKHEAD PANEL SUPPORT AT ACB BS947 LBL10.<[01] EVALUATED CORROSION ON BULKHEAD SUPPORT BS 947 LBL 10 WL 179; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 ANSDR SWAA2023012786267Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727 - BS847 LBL21.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727+6' REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-0SDR SWAA2023012786268Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT AFT CARGO BAY BS727 - BS767 RBL21.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+5 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PER SRM 53-00SDR SWAA2023012786259Web · corrodedCORROSION ON SUBTHRESHOLD WEB AT FWD CARGO BAY BS456 - BS475 RBL28. MARKED<[01] EVALUATED CORROSION ON WEB; FOUND DEEPEST LOCATION AT BS 462 RBL 28 WL 156; FOUND 0.020 REMOVED FROM ORIG 0.045 IN NUMEROUS 1'X1' AREAS; FOUND TO BE OUT OF LIMITS PER SRM 53-30-15-SDR SWAA2023012786271Shield · corrodedCORROSION ON AFT SHIELD AT FWD CARGO BAY BS500 - BS500A RBL23. MARKED<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] REMOVED DAMAGE AFT SHIELD AT FWD CARSDR SWAA2023012786261Support · corrodedCORROSION ON FLOOR TO SIDEWALL SUPPORT AT FWD CARGO BAY BS500 - BS500D LBL23. MARKED<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500B+10' REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUND TO BE OUT OF LIMITS PESDR SWAA2023012786263Support Angle · corrodedCORROSION ON AFT BULKHEAD TO SIDEWALL SUPPORT ANGLE AT FWD CARGO BAY BS500D RBL25. MARKED.<[01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT RBL 25 REMAINING THICKNESS LESS THAN 0.056' IN AN AREA OF 1X1 FOUND TO BE OUT OF LIMITS PER SRSDR JJBA20230109008Floor Support · crackedCF 3, LH OMEGA BEAM, CRACK SUSPECTED AT FRAME LOCATION 36, 37. CRACK (1X) FOUND ONLY AT FR36. NO MORE ACTION AT FRAME 37. LH OMEGA BEAM REPAIRED WITH ANGLE AT FR 36SDR DALA2023010508531Floor Support · corrodedCORROSION FLOOR BEAM -Y58.25 LOCATED BETWEEN FR67 TO FR70 AT AFT GALLEY AREA. REPLACED FLOOR BEAM -Y160 LOCATED BETWEEN FR67 TO FR70 AT AFT GALLEY AREA AS PER A321 SRM 51-42-11, SRM 51-72-11 AND DRAWING D53472003, ISSUE N, RELEASE DATE:22-APR-22. MEASURE OF COSDR AALA202301049037Expansion Joint · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR PANEL LEFT HAND EXPANSION JOINT LOCATED AT BS 540, WL 208, AND LBL 3. REPLACED EXPANSION JOINT PER AARD 51-00-05-1.SDR AALA202301044112Expansion Joint · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN PASSENGER CABIN FLOOR PANEL RIGHT HAND EXPANSION JOINT LOCATED AT BS 540, WL 208, AND RBL 3. REPLACED EXPANSION JOINT PER AARD 51-00-05-1.SDR JJBA20230103035Floor Support · crackedCF 2, UNDER FLOOR, LH OMEGA BEAM CRACK SUSPECTED AT FRAME 33-35. LH OMEGA BEAM REPAIRED AT FR 33-35 WITH A DOUBLER AND FILLERSDR DALA2023010308526Floor Support · corrodedCORROSION FLOOR BEAM +Y1292 LOCATED BTW FR16 TO FR20 AT FWD GALLEY AREA. RESTORED SURFACE PROTECTION O THE REWORKED AREA AS PER A319 SRM 51-75-12.SDR DALA2023010308524Floor Support · corrodedCORROSION FLOOR BEAM -Y1162.5 LOCATED BTW FR68 TO FR69 AT AFT GALLEY. REPLACED FLOOR BEAM -Y1162.5 LOCATED BTW FR68 TO FR69 AFT GALLEY AREA AS PER A319 SRM 51-72-11.SDR AALA202302215114Rail · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT CARGO COMPARTMENT CENTER BULKHEAD PANEL LOWER SUPPORT RAIL LOCATED AT BS 947.5 AND LBL 8. REPLACED RAIL PER SRM 51-40-02-0G.SDR AALA202302216783Transition Panel · damagedAIRCRAFT IN BASE MAINTENANCE: ELONGATED HOLES IN AFT CARGO COMPARTMENT FLOOR STRUCTURE RIGHT HAND TRANSITION PANEL LOCATED FROM BS 727E TO BS 727I AT S26R. SPLICE REPAIRED TRANSITION PANEL PER SRM 53-00-53-2R-5..SDR REXA2022020300217Frame · corrodedFRAME IS CORRODED AT FS 485.00 BETWEEN STGR 25L AND 25R. REPAIRED FS485.00 FRAME BETWEEN STGR 25L AND 25R IAW MHIRJ REO 690-53-31-739 REV-- DATED 2023-01-12SDR SWAA2023011986050Baffle · crackedFWD CARGO BAY BAFFLE IS CRACKED; BS 460-480 LBL 22 WL 156. BAFFLE REMOVED AND REPLACED IAW SRM 51-40-02 AND DWG 143A7505 REV.SDR REXA2022011900116Floor Support · corrodedFLOOR BOARD SUPPORT IS CORRODED @FS 661.00 + 16 / STGR 27. REMOVED AND REPLACED FLOOR SUPPORT,SDR AALA202301115471Intercostal · corrodedAIRCRAFT IN BASE MAINTENANCE: CORROSION ON AFT GALLEY RIGHT HAND MOUNT FLOOR SUPPORT INTERCOSTAL LOCATED AT BS 271.5 AND RBL 43. REPLACED INTERCOSTAL PER SRM 53-10-51-1A.SDR AALA202301032035Floor Support · crackedAIRCRAFT IN BASE MAINTENANCE: CRACK IN FLOOR SUPPORT BREAK ASSEMBLY LOCATED AT BS 537.45 AND LBL 1. REPLACED FLOOR SUPPORT BREAK ASSEMBLY PER AARD 51-00-05-10.SDR HALA2022123000013Floor Support · corrodedFLOOR SUPPORT WAS FOUND WITH SURFACE CORROSION. REMOVED THE FLOOR SUPPORT. FABRICATED A NEW FLOOR SUPPORT IAW DWG 9936534 AND INSTALLED.SDR CALA2022123003532Shear Web · corrodedRH FR69-70 SHEAR WEB SUPPORT IS CORRODED A3NB-05-3-6056 PER NR 9 294323/38323. RMVD AND RPLD NEW SHEAR WEB SUPPORT ON RH FR69-FR70 AFT CABIN IA W SRM 51-72-11-911-001.SDR CALA2022123003531Shear Web · corrodedRH FR69-70 SHEAR WEB IS CORRODED A3NB-05-3-6056 PER NR9294322/38 322. RMVD AND RPLD NEW SHEAR WEB ON RH FR69-70 AFT CABIN IAW SRM 51-7 2-11-911-001.
Back to JASC 5320