SDR USAA980228Floorbeam · corrodedCLT - DURING A C-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON THE UPPER FLANGE OF FLOORBEAM STA 1640 FROM BL ZERO TO RBL 57-0. CORROSION TASK NR C53-251-03. INSTALLED REPAIR T-CAP AND SPLICE PER REPAIR DOCUMENT T/R 53-15-01. (X)SDR USAA980227Support · corrosionCLT - DURING A C-2 CHECK VISUAL INSPECTION, FOUND CORROSION ON FLOOR SUPPORT CHANNEL 1 INCH BY 21 INCH BL ZERO BETWEEN STA 1640 TO STA 1661. CORROSION TASK CARD NR C53-251-03. DEFECTIVE PART REPLACED WITH IDENTICAL PART. (X)SDR USAABB98053Battery · dischargedLAX - FOUND FLOOR EMERGENCY LIGHT AT ROW 23 INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB98052Battery · dischargedLAX - FOUND POWER PACK IN AFT MID STATION 1310 CONTROL MODULE INSPECTION. MAINTENANCE REPLACED THE POWER PACK. (M)SDR USAABB98032Batteries · dischargedSFO - L1 AND R1 DOOR EXIT IDENTIFIERS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR AWXA9800119Floorbeam · corrodedDURING SCHEDULED C-3 INSPECTION, FOUND STA 1640 BL0 CABIN FLOORBEAM UPPER CHORD CORRODED. NEW SECTION OF FLOORBEAM SPLICED IN IAW, SRM 53-00-51.SDR USAABB98045Batteries · dischargedLAX - EMERGENCY FLOOR LIGHTING INOPERATIVE AT ROWS 9 AND 29. MAINTENANCE REPLACED THE BATTERIES. (X)SDR USAABB98043Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHTS INOPERATIVE AT ALL SEAT POSITIONS. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB98034Duct · rupturedCLT - FL 41 - AFTER TAKEOFF FROM CLT, CREW RECEIVED THE EICAS MESSAGES 'L ENG OVHT' AND 'CABIN ALTITUDE' AND THE 'OVERHEAT' LIGHT ILLUMINATED. THE CREW REDUCED POWER ON THE LEFT ENGINE AT WHICH TIME THE OVERHEAT LIGHT EXTINGUISHED. CABIN PRESSURIZATION COULDSDR USAABB98035Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHTING AT ROWS 1, 4, 6 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB98040Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHTS INOPERATIVE AT ROWS 18, 23, AND 26. MAINTENANCE REPLACED THE BATTERIES. (X)SDR USAABB98039Sign · inoperativeLAX - FOUND R4 EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (X)SDR USAABB98028Batteries · dischargedLAX - EMERGENCY FLOOR LIGHTING INOPERATIVE AT ROWS 1 AND 23. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB98033Batteries · dischargedSFO - FOUND EMERGENCY FLOOR LIGHTS AT ROWS 1, 6, AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB98031Wire · not groundedSFO - EMERGENCY LIGHTS WILL NOT TEST FROM SWITCH AT NOSE GEAR. MAINTENANCE REPAIRED A GROUND WIRE BETWEEN CONNECTOR D40488J AND SWITCH S10035. (M)SDR USAABB98037Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHTING INOPERATIVE AT ROWS 13 AND 18. MAINTENANCE REPLACED THE BATTERIES. (X)SDR USAABB98026Gearbox · failedABQ - FLT 28 - EN ROUTE LAX-PIT, AT FL370 CREW NOTE LEFT ENGINE SPOOL DOWN, ACCOMPANIED BY EICAS MESSAGE 'L ENG LP PUMP'. FLIGHT DIVERTED TO ABQ AND LANDED WITH NO FURTHER INCIDENT. MAINTENANCE REPLACED THE LEFT ENGINE GEARBOX. (M)SDR USAAB98030Batteries · dischargedLAX - FOUND FIRST THREE FLOOR EMERGENCY LIGHTS INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB98024Bar Lock · missingPHL - DURING RON MAINTENANCE, THE R4 DOOR WAS OPENED BY UTILITY PERSONNEL. THE INDICATIONS ON THE DOOR SHOWED THAT THE SLIDE HAD BEEN DISARMED, BUT THE SLIDE DEPLOYED. MAINTENANCE FOUND THAT THE GIRT BAR ON THE SLIDE WAS MISSING A SLIDER (BAR LOCK). IT IS BSDR USAABB98020Batteries · dischargedLAX - EMERGENCY FLOOR LIGHTING INOPERATIVE. MAINTENANCE REPLACED ALL OF THE BATTERIES. (M)SDR USAAB98021Control Module · intermittentLAX - AFT EMERGENCY LIGHT CONTROL MODULE INTERMITTENT. MAINTENANCE REPLACED THE MODULE. (M)SDR USAA980065Floorbeam · corrosionCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION 24 INCHES BY 1 INCH ON FLOORBEAM STATION 377.7 BL 0 TO LBL 24 UPPER FLANGE. REPAIR T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA980064Floorbeam · corrosionCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 46 INCH BY 1 INCH CORROSION AREA ON FLOORBEAM STATION 365 BL 0 TO RBL 46 UPPER FLANGE. REPAIR T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA980063Floorbeam · corrosionCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND A 46 INCH BY 1 INCH CORROSION AREA ON FLOORBEAM STATION 345 BL 0 TO RBL 46 UPPER FLANGE. REPAIR T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA980062Sill · corrosionCLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND CORROSION ON R1 DOOR LOWER SILL RBL 60 STATION 395-418. INSTALLED DOUBLER, REPAIR ACCOMPLISHED ON JL 45-53500-023 PER REPAIR DOCUMENT SRM 53-10-51. (M)SDR USAA980061Crease Beam · corrosionCLT - DURING C-1 CHECK VISUAL INSPECTION, FOUND INTERCOSTAL CORROSION AT RBL 60 STATION 365-395 CREASE BEAM INNER CHORD. REPLACED ONE-THIRD CHORD PER REPAIR DOCUMENT SRM 53-10-51. (M)SDR USAA980069Floorbeam · corrodedCLT - DURING A CHECK VISUAL INSPECTION, FOUND A 217 INCH CORROSION ON FLOORBEAM UPPER CHORD FROM LBL 62 TO RBL 62 STATION 345. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA980068Floorbeam · corrosionCLT - DURING A VISUAL CHECK INSPECTION, FOUND A 61.24 INCH OF CORROSION ON THE FLOORBEAM UPPER CHORD AT STATION 365 FROM BL 0 TO RBL 45.5. INSTALLED T-CAP PER REPAIR DOCUMENT SRM 53-00-51. (M)SDR USAA980067Floorbeam · corrosionCLT - DURING A VISUAL CHECK INSPECTION, FOUND A 126 INCH AREA OF CORROSION ON UPPER CHORD OF FLOORBEAM 377 FROM RBL 10 TO LBL 62. REPAIRED T-CAP PER REPAIR DOCUMENT SRM 53-00-51 AND EA 61271. (M)SDR USAA980066Floorbeam · corrosionDURING A VISUAL CHECK INSPECTION, FOUND A 35 INCH AREA OF CORROSION ON FLOORBEAM UPPER CHORD AT STATION 324 FROM RBL 42 TO RBL 62. UPPER T-CAP REMOVED AND REPLACED BETWEEN LBL 6.0 TO RBL 70.0. REPAIR ANGLE INSTALLED PER EA 61274 AND SRM 51-70-12. (M)SDR USAABB98015Sign · inoperativeLAX - FOUND L4 DOOR EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (X)SDR USAABB98016Sign · inoperativePHL - FOUND EXIT IDENTIFIER AT L4 DOOR INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY.SDR AWXA9800038Wire · brokenDURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PROX EMERGENCY LIGHT ROW 19 INOP. RESPLICED WIRE. OPS CHECK GOOD. STC SA3143NM.SDR USAABB98009Sign · inoperativeLGA - FOUND RIGHT AFT SERVICE DOOR EXIT IDENTIFIER INOPERABLE. MAINTENANCE REPLACED THE EXIT IDENTIFIER ASSEMBLY. (M)SDR USAABB98004Sign · inoperativeLAX - FOUND R1 DOOR EMERGENCY EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE EXIT IDENTIFIER. (M)SDR USAABB98006Light · inoperativeLAX - FLOOR EMERGENCY LIGHTING INOPERATIVE AT ROWS 9 AND 18. MAINTENANCE REPLACED THE LIGHT ASSEMBLIES. (M0SDR USAABB98005Battery · dischargedLAX - FOUND L4 EMERGENCY EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB98002Light · inoperativeLAX - EMERGENCY AISLE LIGHTING AT ROW 1 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSY. (M)SDR AWXA9800728Light · missingDURING ROUTINE MAINTENANCE CHECK, FOUND SEAT MOUNTED EMERGENCY EXIT LIGHT MISSING FROM SEAT 23 A, B, C. INSTALLED EMERGENCY EXIT LIGHT AS REQUIRED.SDR USAABB97167Battery · dischargedLAX - FOUND FORWARD EMERGENCY LIGHT CONTROL MODULE BATTERY NOT TESTING. MAINTENANCE REPLACED THE BATTERY. (M)SDR USAABB97165Fuel Pump · leakingLAS - FL 0017 - FLIGHT EN ROUTE PHL TO LAX WHEN CAPTAIN ADVISED OF POSSIBLE FUEL TOTALIZER/CALCULATED FUEL PROBLEM. FMC CAL + TOL DISAGREE BY 3,000 POUNDS. FUEL QUANTITY DECREASING IN LEFT TANK. ON FLY-BY, LAS CONFIRMED FUEL LEAKING FROM LEFT ENGINE. MAINTSDR USAABB97166Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHTS AT ROWS 1, 4, 6, 19, 29 AND 33 INOPERATIVE. MAINTENANCE REPLACED THE BATTERIES. (M)SDR AWXA9700698Wire · failedDURING ROUTINE MAINTENANCE CHECK, FOUND EMERGENCY FLOOR PATH LIGHTING AT 2C INOP. REPAIRED WIRING, OPS CHECK NORMAL. STC - SA3143NMSDR USAABB97156Light · inoperativeLAX - FOUND EMERGENCY FLOOR LIGHT AT ROW 9 INOPERATIVE. MAINTENANCE REPLACED THE LIGHT ASSEMBLY. (M)SDR USAABB97154Batteries · dischargedLAX - EMERGENCY FLOOR LIGHTS INOPERATIVE AT ROWS 1, 10 18 AND 23. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAABB97153Sign · inoperativeLAX - FOUND L2 EXIT IDENTIFIER INOPERATIVE. MAINTENANCE REPLACED THE EXIT IDENTIFIER. (M)SDR USAABB97152Batteries · dischargedLAX - FOUND EMERGENCY FLOOR LIGHT BATTERIES LOW AT ROWS 9, 13, 18, 23, 26 AND 33. MAINTENANCE REPLACED THE BATTERIES. (M)SDR USAA980044Floorbeam · corrosionCLT - DURING C-4 VISUAL INSPECTION, FOUND CORROSION THE ENTIRE LENGTH OF FLOORBEAM STATION 1640 TOP AND BOTTOM SURFACE OF UPPER CAP. REMOVED T-CAP INSTALLED REPLACEMENT CHORD, REPAIR ANGLES AND REPAIR STRAPS PER REPAIR DOCUMENT EA 60716 AND SRM 53-00-51 FIG 2SDR USAA970353Frame · corrosionCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION BETWEEN NUT PLATE HOLES STATION 1520 STRINGER 26-27 ON FRAME ASSY. INSTALLED REPAIR CHANNEL PER REPAIR DOCUMENT EA 60729. (M)SDR USAA970352Frame · corrodedCLT - DURING C-4 CHECK VISUAL INSPECTION, FOUND CORROSION BETWEEN NUT PLATE HOLES AT STATION 1500 STRINGER 26-27 ON FRAME ASSY. INSTALLED REPAIR CHANNEL PER REPAIR DOCUMENT EA 60729. (M)
Back to Boeing 757-225