Douglas DC-8-73F
Service difficulty reports · 15,471
Newest first. General aviation reporting is voluntary.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = 'DC873F' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UPS98827482Splice · corrodedINSPECTION TYPE-C CK, SEAT TRACK E CORRODED FS 759 TO 1100. REMOVED CORROSION IAW DC8 SRM 511-8, 53-2-3. FOUND AT FS 1040, OUT OF LIMITS CORROSION. REMOVED SEAT TRACK FROM 1030 TO 1050, FABBED, DRILLED, INSTALLED NEW SECTION IAW DC8 SRM 53-2-3 AND 51-1-8.SDR UPS98827481Seat Track · corrodedINSPECTION TYPE-C CK, SEAT TRACK G HAS CORROSION AT STA 800 TO STA 1100 AS MARKED. REMOVED CORROSION ON SEAT TRACK IAW DC8 SRM 51-1-8 AND INSTALLED 3 SEAT TRACK PLUG ON STA 941, 917, 816 IAW DC8 SRM 53-2-3 FIG 6D. TREATED ALODINED AND PRIMED IAW DC8 SRM 51-1SDR UPS98827480Plug · corrodedINSPECTION TYPE-C CK, SEAT TRACK D BETWEEN STA 860 AND 880 HAS CORRODED SEAT TRACK PLUG ON BOTTOM SIDE. REMOVED AND REPLACED PLUG AND SPLICE IAW DC8 SRM 51-3-0.SDR RRXA98368Fitting · damagedDURING A MAINTENANCE VISIT, FITTING (P/N 3755840-1), AT STA 834 AND LONGERON 21 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SSDR DHL9880305CDeflector · crackedAT C CHECK, NR 2 ENGINE, NOSE COWL ANTI-ICE DEFLECTOR FROM 3 TO 9 O'CLOCK CRACKED. TRIMMED AREA PER SRM 51-1-8.SDR DHL9880304CDeflector · crackedAT C CHECK, NR 3 ENGINE NOSE COWLING ANTI-ICE DEFLECTOR HAS 6-8 CRACK ACROSS PANEL AT 11 O'CLOCK POSITION. REPAIRED PER SRM 51-1-8. N/R 505.SDR UPS98827649Longeron · crackedINSPECTION TYPE C-CK, LT WHEEL WELL LONGERON 24 CRACKED APPROX 2 INCHES AT STA 862. REMOVED AND REPLACED LONGERON 24 IAW TIMCO WORK CARD 90453100.SDR UPS98827635Frame · crackedINSPECTION TYPE C-CK, MAIN CABIN STA 1480 LONG 21R FRAME CRACKED. REMOVED GILLINER FOR ACCESS. REMOVED DAMAGED CLIP, FAB REPLACEMENT CLIP IAW DAC DWG 5773480. HEAT TREATED CLIP IAW TPS-1003, DRILLED DEBURNED CLIP, TREATED AND PRIMED IAW DC8 SRM 51-1-8. INSSDR UPS98827621Support · corrodedINSPECTION TYPE C-CK, STA 25 FLOOR SUPPORT CORRODED CUSP TO CUSP. REMOVED DAMAGED FLOOR SUPPORT AT STA 25 CUSP TO CUSP, FAB NEW SUPPORT IAW DC8 53-3-2 AND DOUGLAS DWG 5888367. ALODINED AND PRIMED FLOOR SUPPORT IAW DC8 SRM 51-1-8. INSTALLED FLOOR SUPPORT IASDR UPS98827620Intercostal · crackedINSPECTION TYPE C-CK, STA 90 ABOVE L33R INTERCOSTAL CRACKED TOP FLANGE. REMOVED AND REPLACED INTERCOSTAL IAW DC8 SRM 51-1-21. FABRICATED INTERCOSTAL IAW DAC DWG 5750726. ALODINED AND PRIMED IAW DC8 SRM 51-1-8.SDR UPS98827483Splice · corrosionINSPECTION TYPE-C CK, LONG 33 RT END SPLICE TO FRAME CORRODED STA 70. REMOVED CORROSION IAW DC8 SRM 51-1-8. ALODINED AND PRIMED IAW DC8 SRM 51-1-8.SDR RRXA98344Plating · crackedDURING A MAINTENANCE VISIT, FOUND NUMBER 3 PYLON, LEADING EDGE WITH .5 INCH CRACK. REMOVED DAMAGED SECTION, FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05083.SDR RRXA98354Hinge · gougedDURING A MAINTENANCE VISIT, FOUND RIGHT INBOARD FLAP, HINGE, (P/N 5642960), GOUGED. REPAIRED HINGE BY BLENDOUT, FABRICATED 6 FILLERS, 4 RUB STRAPS AND INSTALLED IAW FAA APPROVED TIMCO ENGINEERING SKETCH REO-05139.SDR RRXA98353Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND FLOORBEAM WITH CORROSION DAMAGE BEYOND LIMITS IAW DC-8 SRM, AT STA 781.5 AND BLL 2 TO BLL 10. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SDR RRXA98352Fitting · damagedDURING A MAINTENANCE VISIT, FITTING (P/N 3616944-2), AT STA 832 AND LONGERON 21 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SSDR RRXA98351Floorbeam · damagedDURING A MAINTENANCE VISIT, FOUND INBOARD FLANGE OF FLOORBEAM AND FRAME, STRUT WITH TOOL DAMAGED BEYOND LIMITS IAW DC-8 SRM AT STA 380, BLL. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DERSDR DHL98807006Cover · damagedRT WING I/B FLAP ACTUATOR SUPPORT COVER PANEL DAMAGED WING LOWER SURFACE STA 98. REMOVED DAMAGED PANEL, CUT OUT DAMAGED SECTION OF INTERNAL AND EXTERNAL SKIN, EXTERNAL SKIN FILLER, 3.75 X 2.5, EXTERNAL DOUBLER, 6 X 6.25 INTERNAL FILLER 4.25 X 4.125. FABRICTSDR DHL98805002Longeron · crackedFUSELAGE LT O/B BETWEEN FS 140 TO STA 160 APPROX LONGERONS L-25L AND L-26L HAS A CRACK. CUT OUT DAMAGED SECTION BETWEEN FS 140 AND 160. FABRICATED AND INSTALLED REPAIR DOUBLER PER SRM 51-1-8.SDR RRXA99580Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99579Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99578Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99577Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99576Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99575Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA99574Web · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON WEB ON TORQUE BOX AT LONGERON 31R AT STA 270O 280. DAMAGED BEYOND LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED WEB IAW DAC DWG 5753892. LOCATED HOLES IN NEW WEB IAW DC-8 SRSDR RRXA98350Frame · corrodedDURING A MAINTENANCE VISIT, FOUND INBOARD FRAME, STRUT WITH CORROSION DAMAGED BEYOND LIMITS IAW DC-8 SRM AT STA 1240, BLL. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMCO DER ENGINEERING SKETCSDR RRXA98345Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND INBOARD FLANGE OF FLOORBEAM AND FRAME, STRUT WITH CORROSION DAMAGED BEYOND LIMITS IAW DC-8 SRM AT STA 1480, BLR. REMOVED DAMAGED SECTION, TREATED AREA IAW DC08 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMSDR DHL98807005Fitting · brokenRIGHT WING I/B FLAP ACTUATOR SUPPORT FITTING FOUND BROKEN AT STA 98. REMOVED AND REPLACED FITTING PER DC-8 MM 27-51-9.SDR UPS98827244Bulb · failedINSPECTION TYPE-N/A, MAIN ENTRY DOOR EMERG LIGHTS INOP. RELAMPED EMER LIGHTS, OPS CHECK GOOD.SDR UPS98827243Door · crackedINSPECTION TYPE-B CK, NR 2 PIT DOOR, FWD UPPER CORNER CRACKED WHERE ROLLER SUPPORT BOLTS TO DOOR FRAME. REPAIRED PER DC8 52-02-0 PG 13.SDR DHL98802001Ins · malfunctionedNR 1 INS DISPLAY FLASHING, ALL OTHER FUNCTIONS NORMAL. NR 2 INS DOES NOT RESPOND TO INPUTS. REALIGNED NR 1 AND NR 2 INS.SDR RRXA98349Floorbeam · corrodedDURING A MAINTENANCE VISIT, FOUND INBOARD FLANGE OF FLOORBEAM AND FRAME, STRUT WITH CORROSION DAMAGED BEYOND LIMITS IAW DC-8 SRM AT STA 1320, BLR. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR IAW FAA APPROVED TIMSDR RRXA98348Skin · corrodedDURING A MAINTENANCE VISIT, FOUND SKIN/PLATING WITH CORROSION DAMAGE BEYOND LIMITS IAW DC-8 SRM, AT STA 1050 TO 1084.5 AND LONGERON 35 LEFT. REMOVED DAMAGED SECTION, TREATED AREA IAW DC-8 SRM 51-1-8. FABRICATED AND INSTALLED REPAIR DOUBLER IAW FAA APPROVED TSDR UPS98827274Fitting · repairedINSPECTION TYPE-C CK, 2 Z-FITTINGS AND STA 1180 AND 1200 L33R TO L34R INSTALLED NOT PER SRM. FABBED 2 501 FITTING IAW DAC DWG 3755841, LOCATED AND DRILLED FITTINGS IAW DC8 SRM 51-1-24. ALODINED AND PRIMED IAW DC8 SRM 51-1-8. INSTALLED FITTING IAW DC8 SRM 53SDR UPS98827268Fitting · corrodedINSPECTION TYPE-C CK, LONG 35R AND 34R ZEE FITTING AT FS 1200 HAS CORROSION. REMOVED CORRODED FITTING, ALODINED AND PRIMED ZEE FITTING. INSTALLED FITTINGS IAW DC8 SRM 51-1-20D.SDR RRXA99466Door · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION DAMAGE TO FORWARD PIT A-PIT DOOR AT STA 280 TO 320 S+42 TO -42. DAMAGE EXCEEDED LIMITS IAW DC-8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC-8 SRM 51-1-8. REPAIR TO BE ON N/R 27693, 27694, .27695, 27696, 27697, 27698.SDR RRXA98343Fitting · damagedDURING A MAINTENANCE VISIT, FITTING (P/N 5615040-2), AT STA 980 AND LONGERON 22 RIGHT FOUND DAMAGED. REMOVED FITTING, FABRICATED NEW FITTING BY MATERIAL SUBSTITUTION. ORIGINAL MATERIAL 7075-T411, SUBSTITIUTED WITH 7075T-T6 IAW FAA APPROVED TIMCO ENGINEERING SDR UPS98827270Fitting · corrodedINSPECTION TYPE-C CK, NR 2 BACK-UP FITTING CORRODED. REMOVED FITTING, FABBED FITTING IAW DAC 3754930. TRIMMED FITTING IAW DC8 SRM 53-2-0 FIG 2D. DRILLED FITTING AND CLIPS TO FIT IAW DC8 SRM 5 1-1-24. ALODINED AND PRIMED IAW DC8 SRM 51-1-8 AND INSTALLED WITSDR RRXA99625Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON FLOOR BOARD SPLICE CLIP AT MAIN CABIN STA 50 TO 280, BL 55. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE IAW DC8 SRM 3-53-7-3 FIGSDR RRXA99614Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON FLOOR PANEL G SPLICE ANGLES AT STA 580 TO 880, LBL 20. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICES IAW DAC DWG 5892159. INSTALSDR RRXA99611Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON FLOOR BOARD SPLICE AT MAIN CABIN STA 50 TO 280, LBL AFT 62. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE IAW DAC DRG 5892159 AND SDR RRXA99613Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON TWO SPLICE CLIPS AT MAIN CABIN STA 880 TO 1000, LBL AFT 62. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED TWO SPLICE CHANNELS IAW DAC DWG 5892159. INSTALLSDR RRXA99605Angle · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON T ANGLE IN AFT PIT AT STA 1060 TO 1080, LONG 35L. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED NEW ANGLE IAW DC8 SRM 51-1-8, 51-1-22, AND DAC DWG 9758507.SDR RRXA99620Frame · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION FRAME TO CUSP FITTING SHIM IN MAIN CABIN AT STA 478 TO 480, BL 21R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)SDR RRXA99619Fitting · corrosionDURING A MAINTENANCE VISIT, FOUND CORROSION FRAME TO CUSP FITTING SHIM IN MAIN CABIN AT STA 458 TO 460, BL 21R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. (CORROSION DAMAGE RECORDED IN EWA CORROSION PROGRAM.)SDR RRXA99618Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON FRAME TO CUSP FITTING AT MAIN CABIN STA 578 TO 580, BL 21R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. INSTALLED NEW FITTING IAW DC8 SRM 51-3-0 AND 51-1-20D. (CORSDR RRXA99617Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ATTACH POINT ON RT FRAME ATTACH FITTING AT STA 120, BL 21R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. DRILLED NEW FITTING IAW DAC DWG 4597643 AND DC8 SRM 51-3-2. (CSDR RRXA99615Splice · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON FLOOR BOARD SPLICE AT MAIN CABIN PLANK G STA 1000 TO 1300, BL 30R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED NEW SPLICE IAW DAC DWG 58921SDR RRXA99623Fitting · corrodedDURING A MAINTENANCE VISIT, FOUND CORROSION ON TOP OF FRAME FITTING AT STA 880, X+60, Z-10. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. FABRICATED AND INSTALLED NEW FITTING IAW DC8 SRM 53-7-1, 51-3-2, AND 51-1-2SDR RRXA99609Frame · corrodedDURING A MAINTENANCE VISI, FOUND CORROSION ON BULKHEAD FRAME ABOVE AFT ACCESSORY COMPARTMENT DOOR AT STA 1540, LONG 35R. DAMAGE EXCEEDED LIMITATIONS IAW DC8 SRM. REMOVED DAMAGE, TREATED AREA IAW DC8 SRM 51-1-8. REMOVED AND REPLACED WITH NEW SECTION OF FRAME
Back to Douglas DC-8-73F