SDR CA051116002Relief Valve · sticking(CAN) HYDRAULIC QUANTITY NR 1 READ ZERO. OVERFOW CAN FULL. THIRD REOCCURANCE. FOUND RESERVOIR LOW PRESSURE RELIEF VALVE STICKING OPEN WHEN RELIEF. ABLE TO DUPLICATE BY TRANSFERRING HYDRAULIC FLUID FROM SYSTEM 2 TO SYSTEM 1 WITH BRAKE AND PARK BRAKE. RESERVOIRSDR HNAA0500096Engine · smokeIN FLIGHT SMOKE IN CABIN AND COCKPIT. USED COCKPIT 02 MASKS. TURNED 13 BLEED OFF AND OPENED OUTFLOW VALVE ON DESCENT TO CLEAR SMOKE AND FLY UNPRESSURIZED, THEN TURNED OFF NR 2 BLEED DIVERTED AND DECLARED EMERGENCY. REMOVED AND REPLACED NR 2 ENGINE.SDR HNAA0500093Engine · malfunctionedNR 2 TORQUE DROPPED FOM 90 PERCENT TO 61 PERCENT WHEN ECU SELECTED TO NORMAL AFTER TAKEOFF WITH NO ILLUMINATION OF NR 2 MANUAL LIGHT. CYCLED BETA LOCKOUT CIRCUIT BREAKER.SDR CA051208011Actuator · cracked15 MINUTES AFTER DEPARTURE, CREW REPORTED THAT THE NR 1 HYDRAULIC SYSTEM FLUID QUANTITY DROPPED TO LESS THAT ONE US QUART, AND PRESSURE WENT TO ZERO. THE AIRCRAFT RETURNED TO BASE UPON WHICH MAINTENANCE DISCOVERED THAT THE RT INBOARD FLIGHT SPOILER ACTUATOR HSDR AU510002120Line · failedNOSE LANDING GEAR ACTUATOR FLEXIBLE HYDRAULIC LINE RUPTURED. LOSS OF NR 2 SYSTEM HYDRAULIC FLUID.SDR CA060219002Regulator · malfunctionedNR 2 ENGINE FORWARD DE-ICE VALVE P/N 28E96-2D WAS FOUND DAMAGED DURING 3 MONTH LUMP INSPECTION WHILE PERFORMING ZONAL TASK CARD 422 (PANEL 422DT) THERE DC FEED CABLES WERE POSITIONED WRONG AND HAD CHAFED THROUGH RUBBER COATING OF TERMINAL AND HAD SHORTED AGAINSDR CA050915003Drive Shaft · sheared(CAN) ON CLIMB-OUT, THE NUMBER 1 ENGINE DRIVEN HYDRAULIC PUMP FAILED AND AIRCRAFT RETURNED TO DEPARTURE AIRPORT. THE NUMBER 1 HYDRAULIC PUMP AND HYDRAULIC RETURN FILTER WERE REPLACED (SHAFT SHEARED ON PUMP) AND AIRCRAFT WAS RETURNED TO SERVICE. TIME SINCE LASDR CA050901001Frame · cracked(CAN) DURING A SCHEDULED DETAILED STRUCTURAL INSPECTION OF AIRCRAFT AT FRAME SPLICES AT STA 136.80 AND STR 15A, 5310/29C. CRACKING WAS FOUND ON FRAME SPLICES AND ADDITIONAL STRAPS AS PER MOD 8/0340, LT AND RT PROCEEDED WITH BOMBARDIERS RD-8-53-3541FOR PERM RESDR CA050912003Wheel Half · cracked(CAN) DURING ROUTINE SERVICE CHECK, THE NR 4 MAIN WHEEL TIRE PRESSURE WAS FOUND TO BE 50 PSI WHEEL ASSY REPLACED AND ROUTED TO YHZ WHEEL AND BRAKE SHOP. DURING INSPECTION PROCESS, NDT INSPECTION REVEALED A CRACK EMANATING FROM THE VALVE STEM SEAT. WHEEL HALF SDR HNAA0500078Hmu · failedA 5 INCH POWER LEVER SPLIT IN CRUISE. REMOVED AND REPLACED HYDRO MECHANICAL UNIT AND FUEL PUMP.SDR HNAA0500077Circuit Breaker · failedLOSS OF THE NR1 STBY PUMP PRESSURE INDICATION ON LANDING AND LOSS OF NORMAL BRAKES. REMOVED AND REPLACED RT WHEEL WELL REMOTE CONTROL CIRCUIT BREAKER.SDR CA050823002Altimeter · separated(CAN) WHEN ANTENNA WAS REMOVED FOR INSPECTION AND CLEANING, IT CAME APART IN 2 PIECES. CORROSION WAS FOUND INTERNALLY BETWEEN BASE PLATE AND COPPER ANTENNA PLATE. SUSPECTED CAUSE FOR INTERMITTENT GPWS/RAD ALT SNAGS FOR THE PAST MONTH. ( REFERENCE A/C JOURNESDR CA050825003Actuator · cracked(CAN) AT LINE UP FOR TAKEOFF CREW OBSERVED NR 1 HYD SYSTEM AND IB ROLL SPOILER CAUTION LIGHTS ILLUMINATED. AIRCRAFT RETURN TO BLOCKS. INVESTIGATION REVEALED SIGNIFICANT HYDRAULIC LEAKAGE FROM THE AREA OF THE RT IB SPOILER ACTUATOR. CLOSER INSPECTION OF THESDR CA050817005Cdu · failed(CAN) 1 FMS CDU, DURING CRUISE AT FL210, FMS SCREEN NR 1 FAILED WITH HEAVY SMOKE FROM UNIT, SMOKE CONTINUED FOR ABOUT 1 MIN OR SO, THEN DISSIPATED. (P6 NLG STEER CONT) BREAKER WAS ONLY BREAKER THAT WAS POPPED. RECERTIFICATION DETAILS: 15 AUG 05, NR 1 FMS CDSDR HNAA0500074Actuator · leakingON TOUCHDOWN, LOST NORMAL BRAKING, DUE TO LOSS OF NR 1 HYDRAULIC QUANTITY (NR 1 ISO VALVE CAUTION LIGHT ILLUMINATED) INSPECTED CASE DRAIN NO CONTAMINANTS FOUND, REMOVED AND REPLACED FILTER AND SERVICED HYDRAULICS. REMOVED AND REPLACED LT IB SPOILER ACTUATORSDR HNAA0500067Indicator · inoperativeNO TORQUE INDICATION ON NR 1 ENGINE. REMOVED AND REPLACED TORQUE INDICATOR.SDR HNAA0500068Valve · stickingNR 1 ENGINE OIL TEMPERATURE REACHED 120 DEGREES C AND REDUCED TO 115 DEGREES C WHEN FUEL AUXILLARY PUMP SELECTED ON. REMOVED AND REPLACED OIL COOLER THERMAL VALVE.SDR AU510001975Landing Gear · malfunctionedWHEN THE LANDING GEAR WAS SELECTED `UP` THE NOSE LANDING GEAR DOORS FAILED TO CLOSE. THE GEAR WAS RECYCLED AND THE NLG DOORS INDICATED `CLOSED`. THOROUGH TESTING AND INVESTIGATION IAW MAINTENANCE MANUAL FAILED TO FIND A CAUSE FOR THE DEFECT AND THE AIRCRAFT SDR HNAA0500063Garlock Seal · leakingNR 2 ENGINE OIL PRESSURE FLUCTUATED IN FLIGHT STAYED BETWEEN 40-55 PSI OVER 3 MINUTES. REMOVED AND REPLACED HYDRAULIC PUMP GARLOCK SEAL.SDR CA050712003Line · leakingTHE GEAR WOULD NOT COME UP ON DEPARTURE. THERE WERE PROBLEMS WITH THE NR 2 HYDRAULIC SYSTEM. THE FLIGHT RETURNED FOR MAINTENANCE TO INVESTIGATE. AN EMERGENCY WAS DECLARED. DEFECT 437568 NR 2 HYD ISO VALVE LIGHT ILLUMINATED, LOSS OF SYSTEM 2 FLUID NLG RETRASDR CA050627002Drive Assy · broken(CAN) ON ROUTINE INSPECTION FOUND THAT SECONDARY FLAP DRIVE CORE HAD BROKEN STRANDS AND BLISTERING, CORE REPLACED WITH SERVICEABLE. FUNCTION CARRIED OUT IAW MAINTENANCE MANUAL, AIRCRAFT RETURNED TO SERVICESDR CA050627003Proximity Sensor · unserviceable(CAN) IN CRUISE, PILOTS REPORTED WEIGHT ON WHEELS CAUTION LIGHT WAS INTERMITTENTLY COMING ON. MAINTENANCE PERSONNEL DID PSEU BITE CHECK AND FOUND THAT THE LT MLG NR1 PROXIMITY SENSOR CODE CAME UP. RESISTANCE CHECK OF SENSOR FOUND THAT IT HAD VERY HIGH RESISSDR CA050602004Blade · unserviceable(CAN) PILOT REPORTED THAT THEY HAD NO INDICATION OR LOAD ON B-PHASE OF NR 2 PROPELLER DEICE SYSTEM. INSPECTION OF NR 2 PROPELLER FOUND THAT NR 4 BLADE HAD AN OPEN CIRCUIT IN HEATER MAT. BLADE REPLACED WITH SERVICEABLE GROUND RUNS CARRIED OUT AND FOUND SERVICEASDR CA050502004Window · unserviceableROUTINE WALK AROUND BY MAINTENANCE PERSONAL NOTICED LT SIDE WINDOW HAD DELAMINATION. CLOSER INSPECTION FOUND THAT THE INTERNAL HEATING ELEMENT HAD SHORTED CAUSING THE WINDOW TO DELAMINATE. WINDOW REPLACED WITH SERVICEABLE IAW M/M GROUND RUNS AND PRESSURIZATISDR CA050602007Link · worn(CAN) ON LANDING PILOTS NOTICED A SHIMMY COMING FROM NOSE AREA OF THE AIRCRAFT. INSPECTION OF THE NLG FOUND EXESSIVE PLAY IN THE NLG STEERING LINKS. LINKS REMOVED AND INSPECTED FOUND THE LINK ENDS HAD WEAR AND A CRACK IN ONE OF THE BEARING JOURNALS. SERVICEABSDR CA050608001Wheel · failed(CAN) WHILE TAXING IN AFTER LANDING THE CREW HEARD A LOUD BANG ONCE AT THE GATE THE CREW INSPECTED THE AIRCRAFT AND FOUND THE LT OB TIRE WAS FLAT. MAINT FOUND A 18 INCH SECTION OF THE IB WHEEL HALF OF THE LT OB TIRE WAS MISSING. IT WAS FOUND ON THE TAXIWAY. SDR CA050530009Hose · leaking(CAN) DURING PREFLIGHT INSPECTION , FOUND NOSE WHEEL WELL AREA LEAKING HYDRAULIC FLUID. MAINTENANCE INSPECTION FOUND FLEXABLE HYDRAULIC LINE FOR THE DRAG STRUT ACTUATOR FAILED/LEAKING. HOSE REPLACED , GEAR SWINGS CARRIED OUT. AIRCRAFT RETURNED TO SERVICE. THSDR CA050401001Support · damaged(CAN) DURING ROUTINE MAINTENANCE, A CHAFE WAS FOUND ON THE F/O'S AND CAPTAINS RT RUDDER SUPPORT TUBE (P/N85710012-006) REF IPC 27-20-00, FIG 10, ITEM 230. DAMAGE CAUSED FROM CONTACT WITH SCREW IN TRIM PANEL REFERENCE IPC 27-20-00 FIG. 55 ITEM 90 (TOP SCREW). SDR 20053Engine · malfunctionedAFTER T/O APPROX 500FT AGL, NR 2 ENGINE TQ DROPPED TO 11 PERCENT, ALL OTHER INSTRUMENTS INDICATING NORMAL. ENGINE BEGAN TO SURGING AND UNABLE TO CONTROL WITH THRUST LEVERS. COMMENCED WITH ENGINE SHUTDOWN PROCEDURES. DECLARED EMERGENCY WITH APPROACH. LEVELESDR CA050321001Link · broken(CAN) ON ARRIVAL CREW REPORTED A SHIMMY IN THE NOSE WHEEL DURING LANDING. MAINTENANCE INSPECTED THE NOSE WHEELS AND TIRES WITH NO DEFECTS. INSPECTION OF THE NOSE GEAR STEERING SYSTEM FOUND A BROKEN NOSE WHEEL STEERING LINK. THERE WAS NO OTHER DAMAGE OR EVIDENCSDR CA050309005Support · melted(CAN) ON APPROACH, THE FLIGHT ATTENDANT NOTED A STRONG ELECTRICAL ODOR IN THE CABIN IN THE AREA ADJACENT TO THE PSU PANEL AT SEAT 8A. THERE WAS NO EVIDENCE OF SMOKE OR HEAT IN THE AREA. THE FLIGHT CREW BRIEFED THE PASSENGERS, NOTIFIED THE TOWER AND LANDED UNEVSDR CA050303010Proximity Sensor · broken(CAN) AFTER COMPLETION OF A NORMAL TAKEOFF THE WT ON WHEELS CAUTION LIGHT ILLUMINATED. THE AIRCRAFT LEVELED OUT AND THE DECISION WAS MADE TO RETURN BACK TO BASE. THE A/C LANDED SUCCESSFULLY WITH NO FURTHER INCIDENT. IT WAS NOTED THE THE WT ON WHEELS CAUTION LSDR CA050307008Brake · failed(CAN) WHILE ON ROUTE FROM THE HANGAR THE AIRCRAFT FELT LIKE IT HAD A FLAT TIRE. ADDITIONAL POWER WAS REQUIRED TO CLEAR RUNWAY AND MANOUVERING AREA. ONCE SAFELY CLEAR OF ABOVE MENTIONED AREAS THE AIRCRAFT WAS SHUTDOWN AND INSPECTED. IT WAS NOTE THAT ALL 4 BRAKSDR HNAA0500012Elec Connector · contaminatedMASTER WARNING LIGHT FLICKERED ON/OFF IN FLT FOLLOWED BY NR 2 ENG OIL PRESSURE WARNING LIGHT ILLUMINATED F/O STATED THAT HE DID SEE PRE FLUX NR 2 ENG OIL PRESS BUT IT DID NOT GO BELOW 45 PSI. CLEANED NR 2 ENGINE LOW OIL PRESSURE CONNECTOR SERVICED OIL LEVEL TSDR CA050215003Battery Pack · burned(CAN) WHILE CARRYING OUT A FUNCTION TEST OF THE EMERGENCY LIGHTING SYSTEM DURING A LINE CHECK, THE LT EGRESS LIGHT WAS FOUND UNSERVICEABLE. THE EMERGENCY LIGHT BATTERY PACK FOR THAT LIGHT WAS REPLACED AND THE U/S UNIT WAS SENT TO THE AVIONICS SHOP. WHEN THE BSDR CA050215007Cell · burned(CAN) EMERGENCY LIGHT BATTERY PACK WAS REMOVED FROM AIRCRAFT FOR A SCHEDULED MAINTENANCE RESTORATION TASK 3350/05 AND SENT TO AVIONICS SHOP. DURING INSPECTION OF THE CELLS, BURN MARKS ON STRAPS BETWEEN CELLS WERE NOTED. DURING DEEP CYCLE PROCESS, UNIT DISCHARSDR AU510001821Antenna · failedWEATHER RADAR ANTENNA FAILED.SDR CA050212001Actuator · failed(CAN) IN FLIGHT, CREW NOTICED NR1 OIL PRESSURE DROPPING, VISUALLY NOTICED OIL LEAK ON NR1 FORWARD COWLING, OIL PRESSURE DROPPED TO 45 PSI. CREW SHUT NR 1 ENGINE DOWN AS PRECAUTIONARY MEASURE, LANDED AIRCRAFT AT UNSCHEDULED AIRPORT. MAINTENANCE REPLACED NR1 PRSDR CA050128009Disk · seized(CAN) AFTER STARTED AIRCRAFT, RELEASED PARK BRAKE AND TAXIED NORMALLY , BRAKING AS REQUIRED, DUE TO LONG LINE UP AWAITING TAKEOFF PARK BRAKE WAS APPLIED. WHEN PART BRAKE WAS RELEASED AIRCRAFT UNABLE TO TAXI. MAINTENANCE INSPECTION FOUND BRAKE PISTONS WERE RELSDR CA050125000Pressure Valve · faulty(CAN) THE CREW REPORTED , AFTER GEAR UP SELECTION , LOST NR 2 MAIN AND STANDBY PRESSURE (SPU ON). AFTER APPROXIMATELY 3 MINUTES THEY RECEIVED NR 2 STANDBY PUMP HOT LIGHT. ON SHORT FINAL NR 2 MAIN PRESSURE RETURNED BUT NR 2 STANDBY HOT LIGHT REMAINED ON EVEN TSDR CA050121009Ecu · corroded(CAN) NR1 ENGINE, ENGINE CONTROL UNIT WOULD NOT INDICATE (ON). MAINTENANCE FOUND CORROSION INSIDE AND OUTSIDE CONNECTOR J1. ECU REPLACED. (NOTE: TIMES ARE AIRCRAFT TOTAL TIME NOT ACTUAL PART TIME)SDR CA050201003Bearing · failed(CAN) GENERATOR CAUTION LIGHT ILLUMINATED AND ELECTRICAL LOAD WENT TO (0) SUSPECT STARTER BEARING FAILURE DUE TO HEAVY VIBRATION IN THROTTLE HANDLE. STARTER GEN INSPECTED IN SHOP, WO NR182352, BEARING FAILURE NOTED ON DRIVE END (03-6009-23).SDR CA050107005Rccb · arced(CAN) WHILE INSPECTING NR 2 AC CONTACTOR BOX IN THE RT NACELLE DURING A HEAVY MX CHECK, DISCOVERED THAT HARDWARE THAT HOLDS WIRES ONTO THE REMOTE CONTROL CIRCUIT BREAKER (RCCB) HAD COME OFF AT 3 OF 6 ATTACH STUDS. RCCB IS FOR NR 1 ENG STANDBY HYD PUMP. HARDWASDR CA050211008Computer · malfunctioned(CAN) ON CLIMB OUT WITH CABIN PRESSURIZATION SET TO AUTO IN BOTH NORMAL AND CAB SET MODE THE RATE OF PRESSURIZATION WAS UNCONTROLLABLE UP TO MAX DIFF.A/C RETURNED TO DEPT AIRPORT. SYSTEM OPERATED SERV IN MANUAL MODE. COMPUTER REPLACED AND FUNCTION CHECKS CARRISDR CA050107007Shaft · sheared(CAN) NR 1 ENG HYD PUMP CAUTION LIGHT ILLUMINATED WITH FLAP RETRACTION ON TAKEOFF. NR 1 SPU TURNED OFF, MAIN PRESSURE DEPLETED TO 0 PSI. FLUID QTY REMAINED STEADY. A/C RETURNED TO YYZ. INPUT SHAFT SHEARED FROM AN INTERNAL FAILURE. PUMP DISMANTLED. INTERNSDR CA041115002Blade · brokenDETAILS EXTRACTED FROM MAJOR DEFECT REPORT: DAMAGE IN THE FORM OF SLASH TYPE CUTS TO THE DE-ICE BOOT WAS FOUND ON THE RIGHT PROPELLER, NR 3 BLADE, WHICH AS A RESULT REQUIRED THE PROPELLER BLADE TO BE REPLACED. DURING REPLACEMENT OF THE NR 3 BLADE SERIAL NUMBESDR CA041103008Indicator · reads low(CAN) DURING CRUISE NR 1 OIL PRESSURE DROPPED, PRECAUTIONARY SHUTDOWN OF & FEATHER OF NR 1 ENGINE , AIRCRAFT RETURNED TO ORIGINATING AIRPORT. MAINTENANCE INSPECTION FOUND OIL PRESSURE, TEMP INDICATOR AT FAULT . INDICATOR REPLACED.SDR CA041025003Skin · corroded(CAN) DURING A ROUTINE HEAVY MAINTENANCE INSPECTION WIDESPREAD LEVEL ONE CORROSION WASFOUND ON THE UPPER WING SKIN AT THE MATIN SURFACES OF THE FORWARD AND REAR SPARS. INITIALLY LEVEL ONE CORROSION WAS FOUND JUST AHEAD OF THE REAR SPAR AND JUST AFT OF THE FORWSDR CA041026006Tube · cracked(CAN) BOTH WELDED TUBE ASSEMBLIES P/N 1B1107-1FOUND CRACKED IN ROLLER RADIUS AT THE BASE OF THE CAPTAIN'S SEAT ASSY . DEFECTS WERE NOTED DURING ROUTINE INSPECTION PROCESS IN THE SEAT SHOP , WHEN THIS SEAT WAS REMOVED OFF THE AIRCRAFT DURING AHEAVY MAINTENANCSDR CA041029010Smoke Detector · malfunctioned(CAN) DURING DESCENT , INTERMITTANT BAGGAGE SMOKE WARNING. CREW ELECTED TO DON OXYGEN MASKS AND ADVISE AIRPORT EMERGENCY RESPONSE. UPON ARRIVAL NO EVIDENCE OF SMOKE OR FIRE FOUND. BAGGAGE SMOKE DETECTOR REPLACED. REMOVED UNIT TESTED AS NO FAULT FOUND. AIRCRAFT
Back to Pratt & Whitney Canada PW120A