Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '78710' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE aircraft_model_key = '78710' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026101520388Light · damagedFLOOR PROXIMITY LIGHT 11D DAMAGED. REMOVED AND REPLACED FLOOR PROXIMITY LIGHT 11D REF AMM 33-51-06. OPERATIONAL TEST OK. GOOD FOR SERVICE.SDR CALA2026100820224Battery · inoperativeROWS 44-48 EMERGENCY LIGHTING INOPERATIVE. FOUND A FAULT ON WCU 27. FAULT CODE 6 LOAD FAULT. DURING OPS. FOUND THAT PART OF THE LIGHTS CONTROLED BY WCU 27 ARE ILLIMINATED. SUSPECT A SEAT TRACK. REMOVED AND REPLACED THE ROW 49 POWER SEAT TRACK. NO FIX. REINSSDR CALA2026100820222Light · missingEMERGENCY LIGHT MISSING AT SEAT 47F. TERMINATED NEW SPADE CONNECTORS ON THE WIRES IAW SWPM 20-13-00. INSTALLED A NEW SEAT EMERGENCY LIGHT IAW AMM 33-51-06. OPS CHKD GOOD.SDR CALA2026100520098Transceiver · faultyWEATHER RADAR SYS ADVISORY WXR FUNCTIONS HAVE FAILED OR PARTIALLY FAILED ON BOTH LEFT AND R IGHT SIDES OR MANUALY SELECTED TO A FAILED WXR.DB LEFT INTEG SURVEILLANCE SYSTEM PROC UNIT SEE MEL L/P 3572737 FOR CORRECTIVE ACTION REGARDING LEFT WXR SYSTEM FAULTS. SSDR CALA2026093020020Lens · crackedR3 EMERGENCY EXIT, INDICATOR LIGHT DETACHED. THE LENS WAS CRACKED, LIGHT STILL WORKS. REMOVED AND REPLACED BOTH THE LIGHT AND BEZEL ASSY. OPS CHKD GOOD IAW CMM 25-38-35, REF AMM 33-51-06-00A-720A.SDR CALA2026091719490Acm · odorCABIN AIR CPRSR R1 ACRID SMOKE ODOR IN COCKPT AND CABIN CAC DEACTIVATED. SMOKE OR FUMES IN CABIN INSPECTION PERFORMED IAW AMM REF DMC-B787-A-05-51-99-99A-282A-A. FOUND SATIS. DEFERRED. RIGHT AIR CYCLE MACHINE INSTALLED REF AMM 21-52-02-02B-520A. ALL MECHANICASDR CALA2026091619482Control Unit · inoperativeEMERGENCY FLOOR PROXIMITY LIGHTS ON THE CENTER SEAT ROWS 44 TO 48 DOES NOT COMES ON. REMOVED AND REPLACED WELS CONTROL UNIT LOCATED UNDER SEAT PAN 49E REF AMM 33-51-07. OPS TEST GOOD.SDR CALA2026091619460Unknown · odorACCOMPLISH SMOKE ODOR INSPECTION PER SMOKE OR FUMES IN CABIN INSPECTION IAW AMM DMC-B787-A-05-51-99-99A-282A-A. SMOKE OR FUMES IN CABIN INSPECTION PERFORMED IAW AMM DMC-B787-A-05-51-99-99A-282A-A. FOUND SATIS.SDR CALA2026091519420Light · inoperativeEMERGENCY PATHWAY LIGHTS AT SEATS 8D, 9D, & 57D DO NO ILLUMINATE. REMOVED AND REPLACED DAMAGED PATHWAY LIGHTS AT SEATS 8D, 9D, & 57D. OPS CHKD GOOD IAW AMM 33-51-06.SDR CALA2026091519453Light · missingBUSINESS CLASS SEAT 1D FLOOR PATH EMERGENCY LIGHT MISSING. FLOOR PROXIMITY LIGHT - INSTALLATION CARRIED OUT AT SEAT 1D REF.: DMC-B787-A-33-51-06-00A-720A-A SATISFACTORY.SDR CALA2026091119371Battery · inoperativeEMERGENCY FLASHLIGHT BATTERY OESN'T WORKING PROPERLY AT STATION DOOR 1R ACPD AS PER AMM FLASHLIGHT BATTERY REPLACEMENT - REF DMC-B787-A-25-64-00-00B-921A-A. ACFT OK TO SVC.SDR CALA2026090819311Unknown · odorFA REPORTS VERY STRONG ODOR LIKE BURNT POPCORN FOR 3 MIN DURING DESCENT. PERFORMED SMOKE/ODOR CONDITIONAL INSPECTION IAW DMC-B787-A-21-20-F5-72A-421A-A AND DMC-B787-A-05-51-99-99A-282A-A. RAN OVENS, COFFEE MAKERS, CHECKED LAVS, PACKS, COCKPIT AND GALLEYS. NO SDR CALA2026083119073Warning Message · false activationENG EEC C1 RT ENGINE CONTROL IS IN A TIME LIMITED DISPATCH CONDITION. ENGINE CONTROL SYSTEM OPERATING WITH REDUCED REDUNDANCY. DB ELECTRONIC ENGINE CONTROL CHANNEL-A (RIGHT ENG) UPON ARRIVAL FOUND MAINT MESSAGE 73-31212. STATUS MESSAGE ACTIVE BUT CORRELATED SDR CALA2026082618940Light · faultedEMERGENCY PROXIMITY LIGHT OF THE SEAT 8D INOP. FLOOR PROXIMITY LIGHT OF THE SEAT REMOVED AND REPLACED IN AMM REFERENCE: DMC-B787-A-33-51-06-00A-520A-A / DMC-B787-A-33-51-06-00A-720A-A AND ITEM OK. GOOD FOR SERVICE.SDR CALA2026082618942Circuit Card · faultedWING ANTI-ICE CAUTION SYSTEM CANNOT PROVIDE ICE PROTECTION TO 2 OR MORE ZONE PAIRS ON WING OR LOSS OF COMMUNICATION FROM THE WIPCU TO DCA. DB WIPCU SEQUENCE CONTROLLER CARD CHANNEL 3 DB WIPCU SEQUENCE CONTROLLER CARD CHANNEL 2 DB WIPCU SEQUENCE CONTROLLER CARDSDR CALA2026082418851Light · missingSEAT 4F FLOOR MOUNTED LIGHT MISSING. INSTALLED THE LIGHT AT 4F SEAT IAW AMM 33-51-06, TESTED SATISFACTORY.SDR CALA2026082418849Light · missingSEAT 10D PROX FLOOR MOUNTED LIGHT MISSING. INSTALLED MOUNTED PROX LIGHT AT SEAT 10D IAW AMM 33-51-06 SATISFACTORY.SDR CALA2026082118788Actuator · faultyAHM DETECTED MMSG 32-45367, WHEEL 7 ELECTRIC BRAKE ACTUATOR 3 MOTOR WIRE OR LOAD CELL SIGNALS FAILED, LAST 3 OUT OF 4 LEGS WITH EBAC FAULT, REPORT CODE 5, MONITOR CODE 6263. IAW FIM DMC-B787-A-32-40-F1-FAA-421A-A TO CONFIRM FAULT. CON'T ISOLATION. CARRIED BY SDR CALA2026081318555Circuit Board · faultedWING ANTI-ICE SYS WIPS HAD SINGLE OR MULTIPLE INTERNAL/EXTERNAL FAILURES AFFEC TING 1 OR MORE AC SUPPLIES OR BOTH DC SUPPLIES (BUT WIPCU STILL OPERATIVE) OR ONE AC SUPPLY OR MORE THAN 1 SEQUENCER CHANNEL FAILED OR MORE THAN 1 CAN BUSS FAILED OR 2 FAILED TEMP SSDR CALA2026072918086Circuit Breaker · trippedC/B CE3351430 TRIPPED EMERGENCY LIGHTS MTC MSG 42-02164 ACTIVE. FIM DMC-B787-A-42-20-F5-G4A-421A-A. RESET CB. PER FIM ACP CMCF CROWN DOOR 3-2L CCS RDC 05 LRU RPL TEST, PASSED. PER FIM THIS WAS AN INTERMITTANT FAULT. TURNED ON EMERGENCY LIGHTS AND WALKED CABIN,SDR CALA2026072918084Junction Box · damagedBIRD STRIKE ON THE RT LANDING GEAR SEMI STRUT CONTROL UNIT. DAMAGED JUNCTIONS BOX BIRD STRIKE. INSPECTION PERFORMED IAW AMM DMC-B787-A-05-51-18-00A-280A-A, REV 209. FOUND THE JUNCTION BOX ON THE RT MLG SEMI LEVER GEAR DAMAGED.NO OTHER DAMAGE FOUND AFTER CLEASDR CALA2026072117926Battery Pack · faultedDURING EMERGENCY FLASHLIGHT BATTERY INSPECTION WAS FOUND 02 BATTERY THAT NOT WORK PROPERLY AT POSITIONS F/A SEAT FWD DOOR L1 AND F/A SEAT DOOR 4R. PERFORMED REPLACEMENT OF FLASHLIGHT BATTERY AT POSITIONS F/A SEAT FWD DOOR L1 AND F/A SEAT DOOR R4 AS REF DMC-B78SDR CALA2026072017882Lens · damaged1F PROXIMITY LIGHT LENS DAMAGED. R & R 1F FLOOR PROXIMITY LIGHT LENS REFER AMM DMC-B787-A-33-51-06-00A-520A-A (REMOVAL) & AMM DMC-B787-A-33-51-06-00A-720A-A. TEST OK. GOOD FOR SERVICE.SDR CALA2026071517791Oven · smokeOVEN 407 SMOKE WHEN DOOR OPEN. DPWRED. SMOKE DISIPATED. OVEN WAS PREVIOUSLY CLEANED AT LAST STATION L/P 9574711. AFTER SMOKE OR FUMES IN CABIN INSPECTION AMM 05-51-99, IF OVEN IS CONFIRMED SOURCE OF SMOKE, REMOVED AND REPLACED OVEN AT 407 IAW AMM 25-32-00. SDR CALA2026071217708Light · inoperative35D SEAT EMERGENCY LIGHT DOES NOT COME ON, REMOVED AND REPLACED 35D SEAT AISLE EMERGENCY LIGHT AS REF. AMM DMC-B787-A-33-51-06-00A-720A-A. CHECKED ITEM OK.SDR CALA2026070917621Oven · smokeALL SIX AFT GALLEY OVENS SMOKING WITH LOUD HUMMING NOISE 706 707 LARGE WHITE SMOKE FA SAYS SMELLS LIKE ELECTRICAL SMOKE DURING OVEN OPERATION.AFTER SHUTTING OFF OVENS706 707., 711 710 709 SERVICE REQUIRED LIGHT CAME ON FA PULLED ALL OVEN CBS.OBSERVED SIGNS OF SDR CALA2026070817610Battery · inoperativeF/A SEAT FLASHLIGHT BATTERY AT DR 4R INOPERATIVE. REMOVED AND REPLACED F/A SEAT FLASHLIGHT BATTERY AT R4 DOOR IAW AMM 25-64-00. OPS TESTED OK. GOOD FOR SERVICE.SDR CALA2026070717602Light · unknownF/A REPORTS EMERGENCY LIGHTS ON DOOR 2L+R NOT EMERGENCY LIGHTS KEEPING ON. IT IS DOOR LIGHTS AT 2L AND 2R WAS ON. ALL LIGHT ARE NORMAL.SDR CALA2026070517550Light · damagedBE PINNACLE/RC ASPIRE ECON SEAT INSPECTION: - PROXIMITY LIGHT AT SEAT #45F DAMAGED REMOVED AND REPLACED PROXIMITY LIGHT AT SEAT #45F. AS REFERENCE IFM CMM: 25-21-40. ITEM GOOD FOR SERVICE.SDR CALA2026070517548Light · damagedBE PINNACLE/RC ASPIRE ECON SEAT INSPECTION: - PROXIMITY LIGHT AT SEAT #56D DAMAGED. REMOVED AND REPLACED PROXIMITY LIGHT AT SEAT #56D. AS REFERENCE IFM CMM: 25-21-40. ITEM GOOD FOR SERVICE.SDR CALA2026070517546Light · damagedBE PINNACLE/RC ASPIRE ECON SEAT INSPECTION: - PROXIMITY LIGHT AT SEAT #39D DAMAGED REMOVED AND REPLACED PROXIMITY LIGHT AT SEAT #39D. AS REFERENCE IFM CMM: 25-21-40. ITEM GOOD FOR SERVICE.SDR CALA2026070517554Circuit Card · faultedWING ANTI-ICE ZONE LOSS OF WING ICE PROTECTION HEATING FOR ONE SYMMETRIC ZONE PAIR. WING ANTI ICE ZONE STATUS MESSAGE, REPLACE CARD REF AMM AMM B787-A-30-11-03-00A-720A-A. INSTALLED SW PERFORMED GROUND TEST ALL TEST PASSED. NO MESSAGES AC OK TO CONTINUE.SDR CALA2026070617561Fan · faultedDUE TO MULTIPLE LAV/AFT GALLEY LOW AIRFLOW AND LAVATORY/GALLEY FAN 1 MESSAGE WITH ADDITIONAL ITEMS OF LAV ODOR AT LAV "C", REMOVE AND REPLACE LAV/GALLEY FAN 1 PER AMM 21-26-06-00A. WORK IN CONJUCTION WITH FUP L/P 9388980. CONTACT TOMC WITH ANY QUESTIONS. CARRISDR CALA2026062217212Unknown · odorOVEN AT BS 710 HAS ABURNING PLASTIC ODOR. OPERATED OVEN 710 SEVERAL TIMES CAN NOT DUPLICATE BURNING PLASTIC SMELL.SDR CALA2026061717153Unknown · odorMULTIPLE F/AS REPORTED BURN ODOR THRU OUT CABIN. PILOTS INVSTIGATED AND REQUESTED MAINTENANCE DEBRIEF CREW. CABIN CREW STATED AN ODOR, COMING FROM DOOR ONE LT BOTTOM AFT BY EXIT LIGHT AND SHE ALSO STATED ODOR WAS COMING FROM IFE CABINET & SAID OTHER CABIN CRESDR CALA2026061016982Light · missingEMERGENCY PROXIMITY LIGHT FOUND MISSING AT SEAT 1D REPLACED PROXIMITY LIGHT WITH REF AMM DMC-B787-A-33-51-06-00A-520A-A AND DMC-B787-A-33-51-06-00A-720A-A. ITEM OKSDR CALA2026060116716Oven · odorOVEN 707 HAS BURNING ELECTRICAL SMELL. CREW TURNED IT OFF. FORM 46-6020. ATTACHED INSPECTED INSIDE OF OVEN. OVEN CLEAN. NO SPILLS. OVEN SHOWS. NO FAULTS ON SELF TEST REMOVED OVEN AND INSPECTED CONNECTIONS ON OVEN SIDE ALSO AIRFRAME SIDE. NO SIGNS OSDR CALA2026052816605Oven · dentedOVEN/WARMERSMOKING OR SPARKING IN AFT GALLEY OVENS 706 707 708 709 710 711 SMOKE FROM BEHIND OVENS ON DEPARTURE. SHUT OVENS OFF AND PULLED OVEN CIRCUIT BREAKERS. SMOKE APPEARED TO DISSIPATE. TURNED ON OVEN 711 WITH STEAM FUNCTION AND AFTER 15 MINUTES APROX, OSDR CALA2026051816331Smoke Warning · false indicationSMOKE REST UPPER DR 4 CAUTION SMOKE IS DETECTED IN THE UPPER CREW REST COMPARTMENT AT DOOR 4. F/A REST SMOKE ALERT. NO SMOKE PRESENT. CHECKED ALL FAULT HYSTORY AND PRESENT LEG FAULTS NO FIND MESSAGE CORRELATED TO FAULT IN OVERHEAD FLIGHT ATTENDANT REST SMOKE DSDR CALA2026050415921Wire · pulledEMERGENCY PATH LIGHT SEAT 57F HAS A BROKEN WIRE. REMOVED AND REPLACED EPL AT SEAT 57F IN REF TO CMM 25-21-40-4023.ACCOMPLISHED OPERATIONAL CHECK OF EMERGENCY LIGHTS PER B787 AMM 33-51-00-00D-320A-A, ALL LIGHTS ILLUMINATED, NO DEFECTS NOTED.PARTS USED: 78-3300SDR CALA2026042815809Panel · missingFOUND MISSING ONE FAN STATOR BLANK OFF PLATE AND THREE (3) CAPTIVE BOLTS ON ENGINE NR 1, RT SIDE, APPROXIMATELY AT 3?4 O`CLOCK POSITION PERFORMED GVI ON THE ENG IAW AMM DMC-B787-A-G72-00-00-14A-311A-A, NOTHING ABNORMAL WAS FOUND AT THE ENGINE, TEST FROM THE NUSDR CALA2026042715730Light · brokenPASSENGER SEAT 9D AFTER CIRCULAR PROXIMITY LIGHT INOPERATIVE. R/R PASSENGER SEAT 9D AFTER CIRCULAR PROXIMITY LIGHT REF. AMM 33-51-06, OK.SDR CALA2026040615096Unknown · odorODOR FROM PREV MSG REPOR TED AT DOOR 1 AND 2. UPON ARRIVAL NO ODOR SMELL FOUND . AMM CONDITIONAL INSPECTION PFMD AS PER AMM DMC-B787-A-05-51-99-99A-282A . NO DAMAGE/FAULT FOUND. OPERATE PACKS ONE AT TIME. NO STS MSG IN VIEW. PERFORMED FIM TASK PROCEDURE DMC-B7SDR CALA2026040315061Heater · odorFLIGHT ATTENDANTS AT DOORS 1L AND 1R REPORT BURNING ODOR FROM FWD GALLEY AREA JUST AFTER LIFTOFF. ODOR DISSIPATED WITHIN A COUPLE OF MINS. ALL GALLEY OVENS & COFFEEMAKERS WERE OFF WHEN ODOR WAS NOTICED. LOCKING CREW REPORTED PLASTIC BURNING ODOR FOR 2 MINS ASDR CALA2026040315052Drain · inoperativeTWO FORWARD LAVATORIES, BY DOOR 1 AS WELL AS FRONT GALLEY SINK NOT DRAINING AND OVERFLOWING WITH A FOUL ODOR. FOUND LAV B VACUUM INOPERATIVE, VALVE STAYS OPEN. REQUEST MEL FOR LAVATORY B AND LAV IS UNSUABLE. PLUG VACUUM PART # K38002-1 HAS BEEN INSTALLED INSDR CALA2026040815223Repair · delaminatedFOUND A REPAIR WITH DELAMINATION AT STA345 BETWEEN S-33L AND S-34L.SDR CALA2026032014708Unknown · odorL3 DOOR PORTABLE OXYGEN COMPARTMENT HAS CHEMICAL ODOR. NO LEAKS NO SPILLS. I DIDNT REALLY SMELL ANYTHING. OKSDR CALA2026031214525Lens · missingPROXIMITY LIGHT OF THE SEAT 8D WITH LENS MISSING. REMOVED PROXIMITY LIGHT IAW AMM DMC-B787-A-33-51-06-00A-520A-A, AND INSTALLED IAW AMM DMC-B787-A-33-51-06-00A-720A-A. GOOD FOR SERVICE.SDR CALA2026030214198Light · inoperativeFOUND EMERGENCY LIGHT INOPERATIVE AT SEAT 3D AFT. REPLACED THE LIGHT AT SEAT 3D AFT AND TEST FOUND RESULT NORMAL IAW AMM 33-51-06-00A-520A/720A-A REV.205.SDR CALA2026030214196Light · inoperativeFOUND EMERGENCY LIGHT INOPERATIVE AT SEAT 1D AFT. REPLACED THE LIGHT AT SEAT 1D AFT AND TEST FOUND RESULT NORMAL AS PER AMM 33-51-06-00A-520A/720A-A REV.205. FOUND LIGHT ASSEMBLY IN OPERATIONAL CONDITION.
Back to Boeing 787-10