N713AA
Service difficulty reports not matched to an aircraft · 135
They name N713AA, but no registry record covers the date, the aircraft registered then was built later, or the report describes another aircraft. Newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N713AA' AND registry_match IS NULL ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE n_number = 'N713AA' AND registry_match IS NULL ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR C8GA20120427006Actuator · damagedRT RAM AIR DOOR AND LOWER ACTUATOR ROD MISSING ON POST FLIGHT INSPECTION. NO DAMAGE TO FUSELAGE NOTED. R & R RIGHT RAM AIR DOOR ACTUATOR, INSTALLED RAM AIR DOOR OPS CHECKED GOOD.SDR C8GA2011000007Shaft · shearedDURING CRUISE OPERATION AT FL 300, THE NR 1 ENGINE HYD SYS "A" LOW PSI LIGHT ILLUMINATED. ACFT DIVERTED WHERE IT LANDED WITHOUT INCIDENT. POST FLIGHT INSP WAS PERFORMED, NOTING THAT THE NR1 ENGINE "A" SYSTEM HYD SYSTEM PUMP WAS AT FAULT. PERFORMED OPS CHECKSDR FOTR2019813815Structure · crackedRT SIDE OF AFT AIRSTAR TORQUE BOX UPPER CORD IS CRACKED AT AIRSTAIR ACTUATOR FITTING. REMOVED UPPER CHORD FROM RT SIDE AFT AIRSTAIR TORQUE BOX STA BS 1263 IAW 51-30-2. INSTALLED NEW ANGLE, PN 65-17517-38. PO NR 20198118 IAW SRM 51-30-2 & SB 53-0129, REV 5.SDR FOTR2019813123Hinge · crackedMCD UPPER AFT MOST SEGMENT FUSELAGE SIDE AFT LOBE IS CRACKED. REMOVED MAIN CARGO DOOR AFT SEGMENT HINGE IAW FREIGHTER MM, FIG 5201B, REV F. FABRICATED NEW SECTION FROM MS20001-16-7200 PO 9002399, DIM 18" X 3.75" IAW FREIGHTER MM FIG 5201B REV F. LOCATED ANDSDR FOTR2019813835Shear Tie · corroded(FOTR) CORROSRION ON SHEAR TIE AT BS 720 BETWEEN STR 28L-28R. REMOVED CORRODED SHEAR TIE FROM STA 720 BETWEEN STR 28L & 28R IAW SRM 51-30-2. FABRICATED SHEAR TIE FROM 7075-T6 .063" PO 90010179 IAW SRM 53-10-2 FIG 3, 53-10-4 FIG 11, 51-30-5, 51-30-6. TREATED ANSDR FOTR2019813414Floorbeam · cracked(FOTR) MAIN CABIN OVERWING FLOORBEAM T-CORD CRACKED AT RADIUS BS 760, LBL 45.50. REMOVED DAMAGED T-CORD FROM BS 760 LBL 45.50 IAW SRM 51-30-2. FABRICATED NEW T-CORD FROM BAC15061105-7075-T6 PO 2019835 DIM 110" IAW SRM 53-10-2, FIG 7 INSTALLED T-CORD IAW SRM 51SDR FOTR2019813281Frame · damaged(FOTR) STA 950B FRAME HAS 2 FASTENERS W/NO ED AT GILLINER SUPPORT IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGE AREA 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2EA PARTS MAT USED 7075-0 .071 PO 90016396 DIM 13.7500" X 3", 13.7500" X 4" IAW SRM 53SDR FOTR2019813419Intercostal · corroded(FOTR) CORROSION ON LOWER FLANGE OF INTERCOSTAL AT BS700 BETWEEN STR 28R - 27R. REMOVED INTERCOSTAL AT STA 700 BETWEEN STR 28R AND 27R IAW SRM 51-30-2. FABRICATED INTERCOSTAL FROM 7075-T6 .032" PO 90010274 DIM 19.5" X 8.5" IAW SRM 53-10-2 FIG 3, SRM 51-20-1 FISDR FOTR2019813838Intercostal · corroded(FOTR) CORROSION ON INTERCOSTAL BETWEEN BS 720-700 STR 27R-28R. REMOVED CORRODED INTERCOSTAL FROM BETWEEN STA 720-700, STR 27R-28R IAW SRM 51-30-2. FABRICATED NEW INTERCOSTAL FROM 7075-T6 .032" 19.5" X 8.5" PO 90010274 IAW SRM 53-10-2, FIG 3. SRM 51-20-1 FIGSDR FOTR2019813745Floorbeam · damagedBS 420, RBL 60, FLOORBEAM HAS DOUBLE DRILL. CUT OUT DAMAGE AREA DIM 10.5" X 1" IAW SRM 53-410-8, FIG 8. FAB 2 EA ANGLES REPAIRS FROM 7075-0 .090" PO 9009880 DIM 18" X 3" & 7075-0 .071 PO B90010396, DIM 15" X 3" IAW SRM 53-10-8, FIG 8. HEAT TREATED PART FROM SDR FOTR2019813790Skin · corrodedUPON REMOVAL OF INTERCOSTAL FOUND FUSELAGE SKIN TO BE CORRODED BETWEEN BS 700-720 STR 28R-27R. REMOVED 8" BODY FAIRINGS FROM 710 TO 720 LT AND RT IAW SRM 51-30-2. CUT DAMAGE AREA AND FOUND OUT OF LIMITS DIM 53" X 51" FROM STA 680 TO 720+14.5" IAW SRM 53-30-3,SDR FOTR2019813278Frame · damagedBS 950F, FRAME HAS 2 RIVETS W/NO E.D. IN WINDOW BELT AREA. CUT OUT DAMAGE AREA 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2 EA PARTS MAT USED 7075-0 .071" PO 900163-801, REV A; LOCATED AND DRILLED IAW SRM 51-30-5, HEAT TREATED FROM 7075-0 TSDR FOTR2019813426Frame · damagedSTA 720F FRAME HAS FASTENERS W/NO E.D. IN WINDOW AREA. CUT OUT DAMAGE AREA DIM. 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR MAT, USED 7075-0 .071" PO NR 90016396. DIM 13.5" X 3" AND 13.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATED PARTS FROM SDR FOTR2019813280Frame · damagedBS 910 FRAME HAS 2 FASTENERS W/NO E.D. AT GILLINER SUPPORT IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGE AREA DIM 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2EA PARTS MAT USED 7075-0 .071" PO 90016396. DIM 14.5" X 3", 14.5" X 4" IAW SRM 53-10-4, SDR FOTR2019813744Frame · damagedBS 440, RBL 60 FRAME HAS DOUBLE DRILL AT FLOOR LEVEL. CUT DAMAGE AREA AT STA 440 RT FRAME DIM 1.2500" X 1" IAW SRM 51-40-3. FAB NEW REPAIR FRAME FROM 7075-0 .063" PO NR 9009913. DIM 10" X 4" LOCATED, DRILLED & HEAT TREATED TO T6 CONDITION IAW FAS ENG. REPORT SDR FOTR2019813439Frame · damagedSTA 720E, FRAME HAS FASTENERS W/NO ED IN WINDOW AREA ON LT SIDE. CUT OUT DAMAGE AREA DIM 1" X .7500" FAB FRAME REPAIR 2EA PARTS MAT. USED 7075-0 .071" PO 90016396, DIM 13.5" X 3" & 13.5" X 4", ALL IAW SRM 53-10-4, FIG 1 HEAT TREATED PART FROM 7075-0 TO 7075-TSDR FOTR2019813696Floorbeam · cracked(FOTR) CRACK AROUND BOLT HOLE, FLOORBEAM RBL 12 AT FS 950D. C/W HFEC INSPECTED IAW NDTM PT6. 51-00-00, FIG 23. CRACK NOTED AT FASTENER HOLE. TRIMMED OUT DAMAGE AREA DIM. 4" X 2" IAW SRM 53-10-8, FIG 3 FAB. FLOORBEAM REPAIR UPPER CORD MAT USED BAC1505-100617 SDR FOTR2019813282Frame · damagedBS 950A FRAME HAS 2 FASTENERS W/NO ED IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGED AREA DIM. 1" X .7500" IAW SRM 53-10-4, FIG 1 FABRICATED FRAME REPAIR 2 EA PARTS MAT USED 7075-0 .071" PO 90016396. DIM. 12.5" X 3" & 12.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATSDR FOTR2019813832Frame · damagedREMOVAL OF GILLINER ATTACH ANGLE ON LT SIDE OF FUSELAGE AT TOP OF WINDOW LEVEL REVEALED DOUBLE DRILL HOLES IN FRAME AT FS 720D. CUT DAMAGED AREA DIM. .800" X .800" AT STA 720D FAB NEW REPAIR PARTS 2EA ANGLES FROM 7075-0 PO 90010396 DIM. 13.2500" X 3". LOCATEDSDR FOTR2019813831Frame · damagedREMOVAL OF GILLINER ATTACH ANGLE ON LT SIDE OF FUSELAGE AT TOP OF WINDOW LEVEL REVEALED DOUBLE DRILL HOLES IN FRAME AT FS 720C. CUT OUT DAMAGED AREA DIM. .800" X .800" AT STA 720C. FAB 2EA REPAIR ANGLES FROM 7075-0 PO 90010396 DIM. 13.5" X 13.5" X 4" IAW SRMSDR FOTR/20198/13725Frame · damaged(FOTR) BWS 910, FRAME LT SIDE OF FUSELAGE HAS A DOUBLE DRILL AT FLOOR LEVEL. CUT OUT DAMAGED AREA DIM .700" X .500" ON FRAME STA 910 LT FLOOR LEVEL IAW SRM 51-40-3, FIG 1. FAB DOUBLER FROM 7075-0 .80" PO 9009327 IAW SRM 51-40-3, FIG 1. TREATED AND PRIMED PARTSDR FOTR/20198/13818Skin · dentedEVALUATE DENTS 2EA AT LT INBD FORE FLAP LOWER SURFACE 62" FROM INBD EDGE. REMOVED DAMAGE SANDED, CLEANED, AND PREPPED AREA IAW SRM 51-40-20. FABRICATED DOUBLER 6" X 9" FROM 2024-T3 .016, PO 9007046 IAW 51-40-20.CLEANED, SEALED, FINISHED REPAIR IAW SRM 51-40-2SDR FOTR20198/13413Floor Support · crackedMAIN CABIN OVERWING FLOORBEAM T-CORD CRACKED AT RADIUS BS 760 45.5. REMOVED DAMAGED T-CORD FROM STA 760-870, RBL 45 IAW SRM 51-30-2. FABRICATED NEW T-CORD FROM BAC1506-1108 7075-T6 PO 2019835 DIM 109.6250" X 3.6250" IAW SRM 53-10-2, FIG 7. INSTALLED T-CORD SDR FOTR2019813376Skin · corrodedCORROSION ON RT OTBD FWD FLAP. REMOVED DAMAGE, SANDED, CLEANED PREPPED AREA IAW SRM 51-40-20. FABBED DOUBLES FROM 2024-T3 .020" PO 9009917, APPROX 12" X 3". HOT BONDED DOUBLER TO PREPPED AREA IAW SRM 51-40-20. CLEANED, SEALED AND FINISHED REPAIR IAW SRM 51-40SDR FOTR2019813418Shear Tie · corrodedCORROSION ON SHEAR TIE AFT SIDE OF BS 700 BETWEEN STR 28L-27L. CUT OUT DAMAGED AREA AT STA 700 BETWEEN STR 27L - 28L DIM 5.5" X 1" IAW SRM 51-10-1. FAB NEW AFT REINFORCEMENT SHEAR TIE FROM 7075-T6 .050" PO 90010289 DIM 6" X 2"IAW SRM 51-10-3 & 51-20-1. LOCATESDR FOTR2019813834Shear Tie · corrodedSHEAR TIE CORRODED AT BS 685 BETWEEN STR 25L & 26L. REMOVED SHEAR TIE AT STA 685 BETWEEN STR 25L-26L IAW 51-30-2. FABRICATED NEW SHEAR TIE FROM 7075-T6 .040" DIM 14" X 4" PO 9009608 IAW SRM 51-20-1. NEW SHEAR TIE TREATED AND PRIMED IAW SRM 51-10-2. SHEAR TIE RSDR FOTR2019813839Stringer · corroded(FOTR) CORROSION ON STR 28L AT BS 68-720. REMOVED STR 28L AT STA 680-720 IAW SRM 51-30-2. FAB NEW STRINGER FROM PN 1498-145 7075-T6 PO 90010545 DIM 41" IAW SRM 53-10-3 FIG 1 & 53-10-2, FIG 9. TREATED AND PRIMED NEW PART IAW SRM 53-10-3 FIG 1& 53-10-2 FIG 9.SDR FOTR2019813833Shear Tie · corroded(FOTR) BETWEEN STR 27R-28R, BS 720 SHEAR TIE CORRODED. CUT OUT DAMAGED AREA AT SHEAR TIE STA 720, STR 27R - 28R 5.5" X 1" IAW SRM 53-10-4, FIG 15 FAB REPAIR SHEAR TIE FROM 7075-T6 .063" PO 90010179 DIM 6" X 2" LOCATED & DRILLED AT STA 720 BETWEEN STR 27R-28R,SDR FOTR2019813535Stringer Splice · corrodedCORROSION ON STRINGER SPLICE AT BS 720, STR 28R. REMOVED STRINGER SPLICE FROM STA 680-720, STR SPLICE 28R IAW SRM 51-30-2. FAB STRINGER SPLICE FROM PN BAC1498-132 7075-T6 PO 2014392 DIM 12" & STRINGER FABRICATED FROM PN BAC1498-145 7075-T6 PO 90010545 DIM 41" SDR FOTR2019813837Intercostal · corrodedCORROSION ON ITERCOSTAL BETWEEN BS 700-720 & STR 27L - 28L. REMOVED INTERCOSTAL AT BS 700-720 BETWEEN STR 27L-28L IAW SRM 51-30-2. FAB NEW INTERCOSTAL FROM 7075-T6 .032" PO 90010274 DIM 19.5" X 8.5" IAW SRM 53-10-2 FIG 3 & 51-20-1 FIG 3 & 51-30-5. PART TREATESDR FOTR2019813836Shear Tie · corrodedCORROSION ON SHEAR TIE AT BS 700 BETWEEN STR 27L & 28L. CUT OUT DAMAGE AREA AT SHEAR TIE BS 700 STR 27L-28L DIM. 5.5" X 1" IAW SRM 53-10-4 FIG 5. FABRICATED SHEAR TIE REPAIR MAT USED 7075-T6 .063" PO 90010179 DIM. 5.5" X 4.5" IAW SRM 53-10-4, FIG 13 TREATED SDR FOTR/20198/13727Seat Track · damagedBS 850-870, LBL 45, SEAT TRACK HAS DOUBLE DRILLED HOLES, REMOVED SEAT TRACK SECTION BS 850 TO 870 LBL45 IAW SRM 51-30-2. FABRICATED NEW SEAT TRACK SECTION FROM BAC1520-1466-7178T6. TREATED AND PRIMED NEW SEAT TRACK SECTION IAW SRM 51-10-2. INSTALLED NEW SEAT TSDR FOTR/20198/13607Seat Track · corrodedCABIN SEAT TRACK IS CORRODED & PIECE IS BROKEN OFF AT RBL 45.5 BETWEEN BS 520 AND 540. REMOVED SEAT TRACK SECTION FROM STA 480 TO 690 RBL 45 IAW SRM 51-30-2, FAB NEW SEAT TRACK SECTION FROM BAC1520-792 7178T6 PO NR 90010566 DIM 210" LONG 2 EA ANGLES FROM BACSDR FOTR/20198/13786Seat Track · damagedBS 850-870 LBL24 SEAT TRACK HAS DOUBLE DRILLED HOLES. REMOVED SEAT TRACK SECTION BS 850 TO 870 LBL 24 IAW SRM 51-30-2. FABRICATED NEW SEAT TRACK SECTION FROM BAC1520-1466-7178T6 IAW SRM 53-10-2. TREATED AND PRIMED PART IAW SRM 51-10-2. INSTALLED NEW SEAT TRACSDR FOTR/20198/13825Seat Track · damagedBS 740-760, RBL 45.5 FLOATING SEAT TRACK ATTACH HOLE IS ELONGATED. REAMED HOLE TO A .5625" DIAMETER IAW SRM 51-20-01. REPLACED BUSHING PN NAS538B7P150 PO 34252267 IAW SOPM 20-50-3 AT BS 740-760, RBL 45.5, FLOATING SEAT TRACK.SDR FOTR/20198/13620Seat Track · chafedFWD EDGE OF LBL24 SEAT TRACK CHAFED AT BS 870. C/A REMOVED SEAT TRACK FROM STA 870 TO 960 LBL 24.75. FAB NEW SEAT TRACK FROM BAC1520-792 7178-T6511 PO NR 90010566 DIM. 90" LONG, FAB 2 ANGLES FROM BAC 1503-1000122 7178T6 PO 90010605 DIM 13.75" X 2.5" AND 13.8" SDR FOTR2019813712Seat Track · corrodedSEAT TRACK IS CORRODED AT LBL 24. CA/ REMOVED DAMAGED SEAT TRACK FROM STA 950+10 TO 1130 LBL 24 IAW SRM 51-30-2. FAB NEW SEAT TRACK FROM BAC1520-792-T65 PO NR 90010566 DIM. 25' LONG. LOCATED & DRILLED AREA & SEAT TRACK, TREATED AND PRIMED SEAT TRACK INSTALLED SDR FOTR2019813611Frame · dentedCABIN HAS FRAME DENTED AT BS 440, STR 7R. CUTOUT DAMAGE AREA DIM. 1" X 2.3750" AT BS 440, STR 7R IAW SRM 53-10-4, FIG 1. FABRICATED PARTS FROM 7075-0 .050" DIM 11" X 3.5" 2EA. PO 20006220 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075-T6. TREATED AND PRISDR FOTR2019813754Frame · dentedBS 380, FRAME HAS DENT AT STR 5R. CUTOUT DAMAGED AREA 1" X 1.2500" AT BS 380 FRAME STR 5R IAW SRM 53-10-4. FABRICATED REPAIR PARTS FROM 7075-0 .050" PO 20006220 DIM 11" X 3.5" 2EA IAW SRM 53-10-4, FIG 1. HEAT TREATED TO T6. TREATED AND PRIMED PARTS IAW SRM SDR FOTR2019813610Frame · dentedCABIN FRAME IS DENTED AT BS 420, STR 7R. CUTOUT DAMAGED AREA DIM. 1" X 1.7500" ON FRAME STA 420, STR 7R IAW SRM 53-10-4, FIG 1, FABRICATED REPAIR PARTS FROM 7075-0 .050" DIM. 11" X 3.5" 2EA PO 20006220 IAW SRM 53-10-4 FIG 1. HEAT TREATED TO 7075-T6. TREATED SDR FOTR2019813804Frame · damagedBS 360 BEWTEEN STR 5L & 6L FRAME SPLICE HAS DRILL HOLE THROUGH RADIUS. REMOVED DAMAGED ANGLE IAW SRM 51-30-2 LOCATED & DRILLED NEW ANGLE PN AE727-2-360-11 IAW SRM 51-20-1 AND AET DWG AE727-0-360 REV H. INSTALLED ANGLE AT BS 360 BETWEEN STR 5 & 6 LT IAW SRM 51SDR FOTR2019813582Frame · crackedBS 985, RBL 24, FRAME SUPPORT IS CRACKED AT LIGHTNING HOLE. REMOVED FLOOR SUPPORT FROM BS 950E-990 BETWEEN RBL 8 TO RBL 16 IAW SRM 51-30-2. REMOVED FRAME IAW SRM 51-30-2. FABRICATED FRAME FROM 7075-0 .040" PO9009504 IAW SRM 53-10-2 AND 51-40-3. HEAT TREATED TSDR FOTR2091813273Frame · damagedBS 1148 AT STR 14R FRAME HAS 2EA DRILL STARTS UNDER GILLINER SUPPORT. CUT OUT DAMAGE AREA DIM. 1.3750" X 1" IAW SRM 51-40-3, FIG 1. FABRICATED ANGLE FROM 7075-0 .100" PO 824299 IAW SRM 51-40-3, FIG 1. HEAT TREATED TO 7075-T6 .100" TREATED AND PRIMED PART IASDR FOTR2019813445Beam · corrodedLT HORIZ STAB EXFOLIATED CORROSION AT T/E BETWEEN ELEV STA 99.97 AND ELEV STA 136.50. REMOVED CORROSION DAMAGE FROM LT HORIZ STABILIZER UPPER T/E BEAM AT SS 132.00, IAW SRM 51-10-6 & FVCI DWG 55-10591-1 REV NEW, MATERIAL LOSS .052" FROM ORIGINAL THICKNESS OF SDR FOTR2019814000Intercostal · crackedBS 360 BETWEEN STRINGER 6 & 7 LT INTERCOSTAL IS CRACKED. CUT OUT DAMAGED AREA .2500" X .5" ON INTERCOSTAL STA 360 BETWEEN STR 6 & 7L IAW SRM 51-40-3, FIG 1. FABRICATED REPAIR DOUBLER FROM 2024-T3 .050" 2.7500" X 4" PO900107515 IAW SRM 51-40-3 FIG 1. TREATED SDR FOTR2019813715Frame · misinstalledBS 890 FRAME HAS FASTENER WITH NO ED IN WINDOW AREA, LT SIDE. CUTOUT DAMAGED AREA DIM .75" X .5' ON STA 890 FRAME IAW SRM 53-10-4 FIG 1. FABRICATED 2 EA DOUBLERS FROM 7075-0 .071 DIM. 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075T6 SDR FOTR2019813714Frame · damagedBS 930 FRAME HAS FASTENER WITH NO ED AT WINDOW AREA, LT SIDE. CUTOUT DAMAGED AREA DIM .75" X .5" ON STA 930 FRAME LT IAW SRM 53-10-4, FIG 1 FABRICATED 2 EA DOUBLERS FROM 7075-0 .071 DIM 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075T6SDR FOTR2019813713Frame · damagedBS 950A, FRAME HAS FASTENERS WITH NO ED IN WINDOW AREA. LT SIDE. CUTOUT DAMAGED AREA DIM. .75" X .5" ON STA 950A FRAME LT IAW SRM 53-10-4, FIG 1 FABRICATED 2 EA DOUBLERS FROM 7075-0 .071, DIM 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO SDR FOTR2019813689Seat Track · corrodedBS 1070-1010, SEAT TRACK LBL 48 IS CORRODED. REMOVED CORROSION ON UPPER FLANGE OF LBL 48, SEAT TRACK SECTION EVALUATED ARE FOUND AREA TO BE OUT OF LIMITS. REMOVED SEAT TRACK SECTION FROM BS 1010-1130 LBL48. FABRICATED NEW SEAT TRACK SECTION FROM BAC1520-792-7SDR FOTR2019813724Seat Track · corrodedBS 960, RBL 24, SEAT TRACK HAS GOUGE. REMOVED CORROSSION FOUND TO BE OUT OF LIMITS IAW SRM 51-10-6 & 53-10-1 FIG 3. FABRICATED SEAT TRACK AND SPLICE FROM BAC1503-100122-7178T6 AND BAC1520-792-7178T6511 AND 7075-T6 .250 TREATED AND PRIMED PARTS IAW SRM 51-10-2
Back to N713AA