JASC 5311
Service difficulty reports · 61,554
Reports filed under 5311 · Fuselage Main, Frame, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '5311' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA107378Frame · corrodedDURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 794.3, BETWEEN STR 24R TO STR 25R. REMOVED AND REPLACED FRAME PER SRM AND BAC DWG.SDR SWAA107345Frame · crackedDURING SCHEDULED 24Y CHECK, FOUND FRAME CRACKED AT BS 500C, BETWEEN STR 19R TO STR 22R. REPAIRED FRAME PER SRM.SDR SWAA107320Splice · corrodedDURING SCHEDULED SPV CHECK, FOUND AFT CARGO COMPARTMENT FAIL SAFE SPLICE CHORD CORRODED AT BS 947, STR 26R. REMOVED AND REPLACED CHORD PER SRM AND BAC DWG.SDR SIMA201033502Frame · chafedDURING MAINTENANCE BASE VISIT FOUND FRAME 19 CHAFED AT STRINGER 3 RIGHT. THE AIRCRAFT WAS REMOVED FROM SERVICE. PERFORMED REPAIR IAW EO-EM-53MR-1698. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR A6WA201140026Frame · damagedSCREW HOLE FOR CONNECTOR PLUG 1J6CE ON FS 559 HAS 2 DRILL STARTS. REPAIRED 2 EA DRILL STARTS NEX TO CONNECTOR PLUG 1J6CE AT FS559 BY BLENDING DAMAGE SMOOTH TO CONTOUR WITHOUT DEEPING DAMAGE IAW REO 601R-53-41-1316 AND SRM 51-12-00.SDR QXEA2010120600845Frame · corrodedC5 CHECK - FR 136.000 FWD SIDE IS CORRODED AT STR 32R AND 33. REMOVED LIGHT SURFACE CORROSION IAW SRM 51-21-00-00-02. MIN REMAINING THICKNESS .038". CONFIRMED CRACK FREE CONDITION REF NTM 51-00-01-250-801. NOMINAL THICKNESS IS .040 IAW SRM 53-20-15-00-01. SDR SIMA201033701Frame · crackedDURING MAINTENANCE BASE VISIT FOUND FRAME 23 TO BE CRACKED IN TWO PLACES BETWEEN STRINGERS 15 RIGHT AND 17 RIGHT. THE AIRCRAFT WAS REMOVED FROM SERVICE. REPAIRED FRAME 23 IAW EO EM-53MR-1695. THE AIRCRAFT WAS RETURNED TO SERVICE.SDR QXEA2010120200833Frame · corrodedC2 CHECK - INTERIOR FUSELAGE LOWER FLANGE AT STA X281.000 HAS LIGHT CORROSION BETWEEN STRINGERS 31P AND 32P. REMOVED CORROSION IAW RD 8/4-53-2344. MEASURED AFFECTED AREA MIN THICKNESS REMAINING .043" REF NTM 51-00-02-250-801. CONFIRMED CRACK FREE CONDITION SDR SWAA107224Frame · corrodedDURING SCHEDULED SPV CHECK, FOUND FRAME CORRODED AT BS 747, BETWEEN STR 26R TO BS 27R. REPAIRED FRAME PER SRM.SDR SWAA107213Frame · corrodedDURING SCHEDULED SPV CHECK, FOUND FRAME CORRODED AT BS 947, BETWEEN STR 27L TO STR 27R. REPAIRED FRAME PER SRM.SDR SWAA107195Frame · corrodedDURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 747, BETWEEN STR 25R TO STR 26R. REPAIRED FRAME PER SRM.SDR SWAA107193Frame · corrodedDURING SCHEDULED 16Y CHECK, FOUND FRAME CORRODED AT BS 500A, BETWEEN STR 28L TO STR 28R. REPAIRED FRAME PER EO.SDR SWAA107188Frame · damagedDURING SCHEDULED 16Y CHECK, FOUND RT FRAME WEB DAMAGED AT BS 235.8, WL 226. REPAIRED WEB PER EA.SDR FOTR2019813281Frame · damaged(FOTR) STA 950B FRAME HAS 2 FASTENERS W/NO ED AT GILLINER SUPPORT IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGE AREA 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2EA PARTS MAT USED 7075-0 .071 PO 90016396 DIM 13.7500" X 3", 13.7500" X 4" IAW SRM 53SDR NACA20100021Beltframe · corrodedCORROSION ON BELTFRAME TO SKIN AT STA 727B FROM LBL 10 TO RBL 10 APPROXIMATELY AFT CARGO PIT. REMOVED CORROSION IAW B737 SRM 51-10-6, BELTFRAME FOUND TO BE BEYOND LIMITS PER 53-10-1 FIG 1, SKIN ALSO FOUND TO BE BEYOND LIMITS PER 53-10-1 FIG 1. REPLACED SKIN SDR QXEA2010120300839Frame · corrodedC5 CHECK - FR 116.000 FWD SIDE IS CORRODED FROM STR 31R TO 32L. CLEANED CORROSION FROM FRAME IAW SRM 51-21-00, FOUND TO BE WITHIN LIMITS IAW SRM 51-14-00. NOMINAL THICKNESS IS .040" WITH A MATERIAL LOSS OF .001". APPLIED ALODINE, PRIMER AND PAINT IAW SRM 51SDR CALA2010120100597Beltframe · crackedSUPPORT TASK BELTFRAME STA 706 HAS CRACK INDICATION BETWEEN STRINGERS S8R AND S9R AT THE A/C OUTLET EXTRUSION SUPPORT BRACKET ATTACHMENT (RIVET BUCKED TAIL) AREA PER MID-FREQ EDDY CURRENT INSPECTION (MFEC). REPAIRED FRAME STA 706-R, PER EC/RA 5311-01514 AND ESDR FOTR2019813278Frame · damagedBS 950F, FRAME HAS 2 RIVETS W/NO E.D. IN WINDOW BELT AREA. CUT OUT DAMAGE AREA 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2 EA PARTS MAT USED 7075-0 .071" PO 900163-801, REV A; LOCATED AND DRILLED IAW SRM 51-30-5, HEAT TREATED FROM 7075-0 TSDR FOTR2019813426Frame · damagedSTA 720F FRAME HAS FASTENERS W/NO E.D. IN WINDOW AREA. CUT OUT DAMAGE AREA DIM. 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR MAT, USED 7075-0 .071" PO NR 90016396. DIM 13.5" X 3" AND 13.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATED PARTS FROM SDR FOTR2019813280Frame · damagedBS 910 FRAME HAS 2 FASTENERS W/NO E.D. AT GILLINER SUPPORT IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGE AREA DIM 1" X .7500" IAW SRM 53-10-4, FIG 1. FABRICATED FRAME REPAIR 2EA PARTS MAT USED 7075-0 .071" PO 90016396. DIM 14.5" X 3", 14.5" X 4" IAW SRM 53-10-4, SDR FOTR2019813744Frame · damagedBS 440, RBL 60 FRAME HAS DOUBLE DRILL AT FLOOR LEVEL. CUT DAMAGE AREA AT STA 440 RT FRAME DIM 1.2500" X 1" IAW SRM 51-40-3. FAB NEW REPAIR FRAME FROM 7075-0 .063" PO NR 9009913. DIM 10" X 4" LOCATED, DRILLED & HEAT TREATED TO T6 CONDITION IAW FAS ENG. REPORT SDR FOTR2019813439Frame · damagedSTA 720E, FRAME HAS FASTENERS W/NO ED IN WINDOW AREA ON LT SIDE. CUT OUT DAMAGE AREA DIM 1" X .7500" FAB FRAME REPAIR 2EA PARTS MAT. USED 7075-0 .071" PO 90016396, DIM 13.5" X 3" & 13.5" X 4", ALL IAW SRM 53-10-4, FIG 1 HEAT TREATED PART FROM 7075-0 TO 7075-TSDR FOTR2019813282Frame · damagedBS 950A FRAME HAS 2 FASTENERS W/NO ED IN WINDOW AREA ON RT SIDE. CUT OUT DAMAGED AREA DIM. 1" X .7500" IAW SRM 53-10-4, FIG 1 FABRICATED FRAME REPAIR 2 EA PARTS MAT USED 7075-0 .071" PO 90016396. DIM. 12.5" X 3" & 12.5" X 4" IAW SRM 53-10-4, FIG 1. HEAT TREATSDR FOTR2019813831Frame · damagedREMOVAL OF GILLINER ATTACH ANGLE ON LT SIDE OF FUSELAGE AT TOP OF WINDOW LEVEL REVEALED DOUBLE DRILL HOLES IN FRAME AT FS 720C. CUT OUT DAMAGED AREA DIM. .800" X .800" AT STA 720C. FAB 2EA REPAIR ANGLES FROM 7075-0 PO 90010396 DIM. 13.5" X 13.5" X 4" IAW SRMSDR FOTR/20198/13725Frame · damaged(FOTR) BWS 910, FRAME LT SIDE OF FUSELAGE HAS A DOUBLE DRILL AT FLOOR LEVEL. CUT OUT DAMAGED AREA DIM .700" X .500" ON FRAME STA 910 LT FLOOR LEVEL IAW SRM 51-40-3, FIG 1. FAB DOUBLER FROM 7075-0 .80" PO 9009327 IAW SRM 51-40-3, FIG 1. TREATED AND PRIMED PARTSDR A6WA201040878Frame · corrodedFRAME STATION 349, CORRODED ON FWD & AFT FACE 6 O`CLOCK POSITION SECTION. REMOVED CORROSION ON FWD AND AFT FACE OF FRAME AT FS 349 IAW SRM 51-21-06 AND REPAIRED FUSELAGE STRUCTURE FS 349 AND STR 26L IAW REO 601R-53-21-1200.SDR DALA1036009855Frame · crackedDURING M-CHECK FOUND LT STA 756 KEEL AREA FORMER CRACKED OTBD END. TRIMMED OFF CRACKED FLANGE, FABRICATED AND INSTALLED REPAIR ANGLE IAW SRM 53-03, FIG 12, 53-13-3 FIG 2, 51-10-4, 51-10-2, 51-10-3, 51-30-2, 51-30-5.SDR FDEA201011234481Frame · damaged2 EACH OPEN HOLES IN FRAME AND REPAIR DOUBLER - STA 950C AT STR 24L. REMOVED REPAIR DOUBLER IAW SRM 51-30-2 REV 103 FORMED NEW REPAIR DOUBLER FROM 7075 O .080" DIM 8" X 4 1/2" IAW SRM 53-10-2 FIG 5 AND 51-20-1 FIG 7 INSTALLED REPAIR DOUBLER IAW SRM 51SDR SIMA201033301Frame · gougedDURING MAINTENANCE BASE VISIT FOUND FRAME 9 ON THE LEFT TO BE GOUGED BETWEEN STRINGER 9 ON THE LEFT AND 13 ON THE LEFT. THE AIRCRAFT WAS REMOVED FROM SERIVCE. REPAIRED FRAME 9 LEFT UNDER LEFT DIRECT VISION WINDOW IAW EMB SRM 53-00-04. THE AIRCRAFT WAS RETURSDR EIAA2010078Frame · crackedBS 820 LEFT TENSION TIE AREA AND STR BELOW HAVE SHEAR TIES TO SKIN CRACKED. INSTALLED STA 820 FRAME SEGMENT PER B747 SRM 53-10-04 FIG 132.SDR AALA20101123TUL05Frame · crackedAFT ACCESSORY 1510 CANT FRAME CRACKED BETWEEN LEFT TAIL CONE LATCHES. INSTALLED DOUBLER PER EA MD80-53-014157 11/19/2010 AND SRM 53-01-00.SDR DALA1033599853Frame · crackedDURING M-CHECK PER AD-FAR MAIN CABIN STA 712 LT MAIN FRAME IS CRACKED INRADIUS BELOW FLOOR. REPAIR PRIOR TO FURTHER FLIGHT REPAIR REQUIRES REQUIRES FAA MANAGER LOS ANGELES ACO APPROVAL PRIOR TO FLIGHT. MUST BE REPORTED ON SSI FORM 5100-3201. REF EM 5320-010SDR DALA1033589853Frame · gougedDURING M-CHECK, FOUND AFT ACCESSORY COMPARTMENT RT SIDE CANTED STA 1243, BETWEEN STRINGER 13-14, FRAME GOUGED ON BOTH SIDES COMPLETELY THROUGH. RT CANTED FRAME STA 1243 BETWEEN STR 13-14 CUTOUT DAMAGE 2" X 1" NDT HFEC VERIFIED DAMAGED REMOVED IAW NDT SPM 06-10SDR FDEA201011234473Frame · misrepairedFWD PIT EXISTING "J " CHANNEL REPAIR AT STA 824 BETWEEN LONGERON 51L AND LONGERON 51R REQUIRES EVALUATION. VISUALLY INSPECTED REPAIR - FOUND NOT IN COMPLIANCE WITH APPROVED DATA. REMOVED OLD REPAIR AND INSTALLED NEW REPAIR IAW SRM 53-30-00, FIG 5, VOL I. THSDR V0XR201011230007Frame · corroded(VOXR) REPAIR AT FROM FRAME 20 IS CORRODED BEYOND LIMITS. R & R REPAIR. W/C 1076SDR AALA20101130AFW03Frame · damagedFOUND TYPICAL DENT DAMAGE TO STATIONS 478 TO 500, FUSELAGE FRAME INNER CHORD BETWEEN STRINGER 30 LEFT AND 31 LEFT DUE TO IMPACT DAMAGE FROM CARGO PALLETS. COLD WORKED AS BEST POSSIBLE, HIGH FREQUENCY EDDY CURRENT SURFACE SCAN BOTH SIDES OF REWORKED FLANGE. FSDR FDEA201011224458Frame · dentedFWD PIT UPPER FLANGE OF FRAME IS DENTED AT BS 720, RBL 35. CUT OUT DAMAGE AREA DIMENSION 1" X 1 1/2" IAW SRM 51-40-3 FIG 1. FABRICATED FRAME REPAIR USING 7075-0, .063" IAW SRM 51-40-3 FIG 1 AND 53-10-2 FIG 3. LOCATED AND DRILLED FRAME REPAIR DIMENSION 8 7/SDR DALA1033099853Frame · crackedDURING M-CHECK FOUND CRACK IN FRAME STA 1230 L2, LT CUT OUT DAMAGED AREA 3.5" X 8750" IAW SRM 53-02, FIG 32. PERFORMED NDT SPM 06-10-01. CRACK WAS REMOVED. FABRICATED -3 REPAIR ANGLE FROM S09530095-03 FABRICATED -29 FILLER FROM .050 7075-T6 FABRICATED L ANGLESDR CALA2010112200593Frame · crackedCABIN INTERIOR FRAME CRACKED STA 1580 BETWEEN STRINGERS 8 AND 9 L/T SIDE AT PSU SUPPORT. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR DOUBLERS ON FRAME AT STA 1580 BETWEEN STRINGERS 8L AND 9L, SRM 53-00-07 REPAIR 1 STEPS 4 A THRU S.SDR CALA2010112200592Frame · crackedCABIN INTERIOR FRAME CRACKED STA 1580 BETWEEN STRINGERS 8 AND 9 R/T SIDE AT PSU SUPPORT. CUT OUT DAMAGED SECTION AND INSTALLED REPAIR DOUBLERS ON FRAME AT STA 1580 BETWEEN STRINGERS 8R AND 9R, SRM 53-00-07 REPAIR 1 STEPS 4 A THRU S.SDR FOTR2019813611Frame · dentedCABIN HAS FRAME DENTED AT BS 440, STR 7R. CUTOUT DAMAGE AREA DIM. 1" X 2.3750" AT BS 440, STR 7R IAW SRM 53-10-4, FIG 1. FABRICATED PARTS FROM 7075-0 .050" DIM 11" X 3.5" 2EA. PO 20006220 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075-T6. TREATED AND PRISDR FOTR2019813754Frame · dentedBS 380, FRAME HAS DENT AT STR 5R. CUTOUT DAMAGED AREA 1" X 1.2500" AT BS 380 FRAME STR 5R IAW SRM 53-10-4. FABRICATED REPAIR PARTS FROM 7075-0 .050" PO 20006220 DIM 11" X 3.5" 2EA IAW SRM 53-10-4, FIG 1. HEAT TREATED TO T6. TREATED AND PRIMED PARTS IAW SRM SDR FOTR2019813610Frame · dentedCABIN FRAME IS DENTED AT BS 420, STR 7R. CUTOUT DAMAGED AREA DIM. 1" X 1.7500" ON FRAME STA 420, STR 7R IAW SRM 53-10-4, FIG 1, FABRICATED REPAIR PARTS FROM 7075-0 .050" DIM. 11" X 3.5" 2EA PO 20006220 IAW SRM 53-10-4 FIG 1. HEAT TREATED TO 7075-T6. TREATED SDR FOTR2019813804Frame · damagedBS 360 BEWTEEN STR 5L & 6L FRAME SPLICE HAS DRILL HOLE THROUGH RADIUS. REMOVED DAMAGED ANGLE IAW SRM 51-30-2 LOCATED & DRILLED NEW ANGLE PN AE727-2-360-11 IAW SRM 51-20-1 AND AET DWG AE727-0-360 REV H. INSTALLED ANGLE AT BS 360 BETWEEN STR 5 & 6 LT IAW SRM 51SDR FOTR2019813582Frame · crackedBS 985, RBL 24, FRAME SUPPORT IS CRACKED AT LIGHTNING HOLE. REMOVED FLOOR SUPPORT FROM BS 950E-990 BETWEEN RBL 8 TO RBL 16 IAW SRM 51-30-2. REMOVED FRAME IAW SRM 51-30-2. FABRICATED FRAME FROM 7075-0 .040" PO9009504 IAW SRM 53-10-2 AND 51-40-3. HEAT TREATED TSDR FOTR2091813273Frame · damagedBS 1148 AT STR 14R FRAME HAS 2EA DRILL STARTS UNDER GILLINER SUPPORT. CUT OUT DAMAGE AREA DIM. 1.3750" X 1" IAW SRM 51-40-3, FIG 1. FABRICATED ANGLE FROM 7075-0 .100" PO 824299 IAW SRM 51-40-3, FIG 1. HEAT TREATED TO 7075-T6 .100" TREATED AND PRIMED PART IASDR FOTR2019813715Frame · misinstalledBS 890 FRAME HAS FASTENER WITH NO ED IN WINDOW AREA, LT SIDE. CUTOUT DAMAGED AREA DIM .75" X .5' ON STA 890 FRAME IAW SRM 53-10-4 FIG 1. FABRICATED 2 EA DOUBLERS FROM 7075-0 .071 DIM. 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075T6 SDR FOTR2019813714Frame · damagedBS 930 FRAME HAS FASTENER WITH NO ED AT WINDOW AREA, LT SIDE. CUTOUT DAMAGED AREA DIM .75" X .5" ON STA 930 FRAME LT IAW SRM 53-10-4, FIG 1 FABRICATED 2 EA DOUBLERS FROM 7075-0 .071 DIM 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO 7075T6SDR FOTR2019813713Frame · damagedBS 950A, FRAME HAS FASTENERS WITH NO ED IN WINDOW AREA. LT SIDE. CUTOUT DAMAGED AREA DIM. .75" X .5" ON STA 950A FRAME LT IAW SRM 53-10-4, FIG 1 FABRICATED 2 EA DOUBLERS FROM 7075-0 .071, DIM 11" X 3" PO 20198132 IAW SRM 53-10-4 FIG 1. HEAT TREATED PARTS TO SDR NACA20100018Beltframe · corrodedBELTFRAME TO SKIN CLIP CORRODED AT FS 947.5 BETWEEN STRINGERS 25L AND 24L. BELTFRAME TO SKIN CLIP AT STA. 947.5 BETWEEN STRINGER 25L AND 24L CORRODED BEYOND LIMITS. FABRICATED AND INSTALLED REPLACEMENT PART IAW B737 SRM 53-10-1 SECT 46 FIG 5 (SHEET 13) AND 5
Back to JASC 5311