SDR FDEA201203150950Frame · dentedFRAME BS 1741 LONGERON 11 LEFT, FOUND DENTED. REPAIRED IAW SRM 53-00-07, FIG 201, REV 48. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203150949Frame · dentedFRAME BS 1661 LONGERON 11 LEFT, FOUND DENTED. REPAIRED IAW SRM 53-00-07, FIGURE 201, REV 48. REPAIR CLASSIFIED AS MAJOR, GMM 6-2-100, REV 114.SDR FDEA201203140933Hinge Fitting · corrodedRT WING (WING SIDE) OTBD FLAP HINGE, CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72. REPAIR CARRIED OUT IAW STEP 1, 2, 9, 10, 11 AND 12 OF EA 1-5750-150447, PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203140931Vane · corrodedRT WING OTBD FLAP VANE FITTING, FOUND CORRODED. REWORKED AND FOUND EXCEEDED LIMITS IAW SRM 57-50-02, FIG 201, REV 48. REPAIR BUSHING FABRICATED AND INSTALLED IAW EA1-5750-150450. PART 1. REPAIR CLASSIFIED MAJOR IAW GMM 6-2-100, REV 114.SDR IPXA2M72313Fmu · inoperativeAT 17000' GOT NR 3 SEL FADEC ALT, THEN NR 3 RPM LOW FOLLOWED BY FLAMEOUT NR 3. SHUTDOWN ENG 3 IAW QRH. RESTARTED NR 3 IAW QRH NORMAL START. REPLACED NR 3 ENGINE FMU, LEAK AND OPS CHECK OK REF MM 73-21-01-4-2.SDR FDEA201203140934Bushing · wornRT WING (WING SIDE) OTBD FLAP, OTBD HINGE, OTBD ACTUATOR HOLE BUSHING WORN. BUSHING REMOVED IAW CMM 20-20-07, REV 72. BORE MEASURED DIA 1.224" AND FOUND EXCEEDED LIMIT IAW CMM 57-44-04, REV 72 , MAX ALLOWABLE DIA 1.220", BUSHING FABRICATED AND INSTALLED IAW SDR FDEA201203140932Hinge Fitting · corrodedRT WING (WING SIDE) OTBD FLAP, OTBD HINGE, INBD ACTUATOR HOLE FOUND CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72. EXISTING HOLE DIA 1.223", FINAL HOLE DIA. 1.249" , MAX ALLOWABLA DIA 1.220" REPAIR CARRIED OUT IAW STEP 1,2,9,10,11 ASDR FDEA201203140930Vane · delaminatedRT WING INBD FLAP VANE LOWER SURFACE FOUND DELAMINATION. R & R IAW AMM 27-50-22-4, REV 72.0. ADJUSTMENT AND TEST CARRIED OUT FOUND SATISFACTORY IAW AMM 27-50-22-5, REV 72.0. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 REV 114.SDR FDEA201203140929Vane · delaminatedRT WING INBD FLAP VANE UPPER SURFACE FOUND DELAMINATION. R & R IAW AMM 27-50-22 REVISION 72.0. ADJUSTMENT AND TEST CARRIED OUT FOUND SATISFACTORY IAW AMM 27-50-22-5, REV 72.0. REPAIR CLASSIFIED AS MINOR IAW GMM 6-2-100 REVISION 114.SDR IPXA2M72384Light · inoperativeEMERGENCY LIGHTING SYS INOPERATIVE. PERFORMED ADJUSTMENT TEST OF EMERGENCY LIGHT SYS IAW AMM 33-51-01-5. OPS CHECKED GOOD.SDR FDEA201203130912Fitting · corrodedRIGHT WING OTBD FLAP VANE FITTING F ECCENTRIC HOLE FOUND CORRODED. FOUND EXCEEDED LIMITS IAW SRM 57-50-02 FIG 201, REV 48 EXISTING HOLE:0.851"(LENGTH), 0.557"(WIDTH). FINAL HOLE 0.944"(LENGTH), 0.660"(WIDTH). MAXIMUM HOLE 0.940"(LENGTH), 0.670"(WIDTH).REPAIR SDR FDEA201203130911Fitting · corrodedLEFT WING OTBD FLAP VANE FITTING B ECCENTRIC HOLE FOUND CORRODED. FOUND EXCEEDED LIMITS IAW SRM 57-50-02, FIG 201, REV 48 EXISTING HOLE:0.873"(LENGTH), 0.623"(WIDTH). FINAL REWORK HOLE 0.930"(LENGTH), 0.706"(WIDTH). MAXIMUM REWORK HOLE 0.940"(LENGTH), 0.640"SDR FDEA201203120888Hinge · damagedRT WING OTBD FLAP, OTBD HINGE BUSHING ON PIVOT HOLE REMOVED IAW CMM 20-20-07, REV 72 . BORE MEASURED DIA 2.315" AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72 MAX ALLOWABLE, DIA 2.3135". NEW BUSHING FABRICATED AND INSTALLED IAW STEP 10 AND 11 OF EA 1-57SDR FDEA201203120894Skin · chafedLT WING NR 3 L/E SLAT TELESCOPIC DUCT CUTOUT FOUND CHAFED. REPAIRED IAW SRM 51-31-01, REV 48. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203120893Hinge Fitting · damagedLT WING (FLAP SIDE) INBD FLAP OTBD HINGE INBD PIVOT HOLE FOUND STEP HOLE. MEASURED AND FOUND EXCEEDED LIMIT IAW CMM 57-52-03, REV 72 . EXISTING HOLE DIA 1.190", /1.253" , MAXIMUM HOLE DIA 1.220" BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-150446, PART 1 SDR FDEA201203120892Bushing · wornLT WING (FLAP SIDE) INBD FLAP OTBD HINGE OTBD PIVOT HOLE BUSHING WORN. REMOVED IAW CMM 20-20-07, REV 72 EXISTING HOLE DIA 1.283", MAX ALLOWABLE HOLE DIA 1.220" HOLE MEASURED AND FOUND EXCEEDED LIMIT IAW CMM 57-52-03, REV 72 . BUSHING FABRICATED AND INSTALLEDSDR FDEA201203120890Bushing · wornRT WING (FLAP SIDE) INBD FLAP, OTBD HINGE INBD PIVOT HOLE BUSHING WORN. BUSHING REPAIRED IAW EA 1-5750-160001, PART 1. EXISTING HOLE DIA 1.283", MAX HOLE DIA 1.220", NEW BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-160001 PART 1, STEP 4 AND 5. REPAIR CLSDR FDEA201203120889Hinge Fitting · damagedRT WING (FLAP SIDE) INBD FLAP OTBD HINGE OTBD PIVOT HOLE FOUND STEP HOLE. REPAIRED IAW EA 1-5750-160001, PART 1. EXISTING HOLE DIA.1.282" /1.192", MAX ALLOWABLE HOLE DIA 1.220". NEW BUSHING FABRICATED AND INSTALLED IAW EA 1-5750-160001 PART 1, STEP 4 ANSDR FDEA201203120885Hinge Fitting · corrodedRT WING (WING SIDE) OTBD FLAP, OTBD HINGE PIVOT HOLE FOUND EXCEEDED CMM LIMITS AFTER BUSHING REMOVAL FOR NDT ACCESS. MEASURED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72 EXISTING HOLE DIA 2.315" MAX ALLOWABLE DIA 2.3135'. REPAIR CARRIED OUT IAW EA 1-57SDR FDEA201203120883Hinge Fitting · corrodedRT WING (WING SIDE) OTBD FLAP OTBD HINGE LOWER MOUNT INBD HOLE FOUND CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72 EXISTING HOLE DIA 0.582', FINAL HOLE DIA 0.598", MAX. ALLOWABLE DIA 0.584' REPAIR CARRIED OUT IAW EA 1-5750-150447, PARSDR FDEA201203120882Hinge Fitting · corrodedRT WING (WING SIDE) OTBD FLAP OTBD HINGE LOWER MOUNT OTBD HOLE FOUND CORRODED. REWORKED AND FOUND EXCEEDED LIMIT IAW CMM 57-44-09, REV 72 . EXISTING HOLE DIA 0.585", FINAL HOLE DIA. 0.598", MAX ALLOWABLE HOLE DIA.0.584" REPAIR CARRIED OUT IAW STEP 3 OF EA 1-5SDR FDEA201203120881Hinge Fitting · corrodedRT WING (WING SIDE) OTB FLAP INBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REWORKED IAW CMM 57-44-09, REV 72. EXISTING THK UPPER:0.412", LOWER:0.408". REMAINING THK UPPER:0.407", LOWER:0.403'. MATERIAL REMOVED: UPPER: 0.005", LOWER:0.005" IAW STEP SDR FDEA201203120880Bushing · wornRT WING (WING SIDE) OTBD FLAP INBD HINGE INBD ACTUATOR HOLE BUSHING WORN. BUSHING REMOVED CMM 20-20-07, REV 72. BORE MEASURED DIA 1.223", AND FOUND EXCEEDED LIMIT IAW CMM 57-44-08, REV 72. MAX ALLOWABLE DIA 1.220", WASHER INSTALLED IAW EA 1-5750-160003, PARSDR FDEA201203120879Hinge Fitting · wornRT WING (WING SIDE) OTBD FLAP INBD HINGE OTBD ACTUATOR HOLE BUSHING WORN. BUSHING REMOVED CMM 20-20-07, REV 72 BORE MEASURED DIA 1.222", AND FOUND EXCEEDED LIMIT IAW 1 CMM 57-44-08 REV 72. MAX ALLOWABLE DIA.1.220" .BUSHING FABRICATED AND INSTALLED IAW STEP 5 SDR FDEA201203120878Hinge Fitting · corrodedRIGHT WING (WING SIDE) OTBD FLAP INBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REWORKED IAW CMM 57-44-08, REV 72. EXISTING THICKNESS UPPER: 0.375", LOWER: 0.355", REMAINING THICKNESS UPPER: 0.365", LOWER: 0.345", MATERIAL REMOVED UPPER: 0.010", LOWER SDR IPXA12M72654Doubler · crackedINSPECTION TYPE: 2C, RT WING FIXED L/E COMPT BEADED DOUBLER CRACKED IN ACCESS 619CB ABOVE OTBD FUEL RECEPTACLE (STA XOS642). REPAIRED RT WING FIXED L/E INTERNAL BEADED DOUBLER BETWEEN XOS636-648 IAW SRM 57-40-02, REPAIR 9, FIG 203 AND EO MD11-5730-42916-C.SDR IPXA2M72576Doubler · crackedINSPECTION TYPE: 2C, RT WING FIXED L/E COMPT BEADED DOUBLER CRACKED INSIDE PANEL 619CB AT FUEL CONTROL PANEL (XOS627). REPAIRED RT WING FIXED L/E INTERNAL BEADED DOUBLER BETWEEN XOS625-629 IAW SRM 57-40-02, REPAIR 9, FIG 203 AND EO MD11-5730-42916-C.SDR IPXA2M72614Panel · damagedINSPECTION TYPE: 2C, LT WING FIXED L/E DOOR 518AB HAS ONE ELONGATED FASTENER HOLE. DURING DISASSEMBLY ALSO FOUND ELONGATED HOLE IN ADJACENT WEB ARB2883- 3. REPAIRED DOOR AND WEB IAW STA SA EA 011-5730-01-A3761 REV IR & EO MD11-5730-46514-A.SDR FDEA201203090844Longeron Splice · crackedDURING X-RAY INSPECTION, FOUND A CRACK ON STA 5-123, LONGERON SPLICE 2 LT. LONGERON REMOVED IAW SRM 51-31-01, REV 48. NEW LONGERON SPLICE FABRICATED IAW DWG A5A7111-501, REV C. NEW FABRICATED LONGERON SPLICE INSTALLED IAW SRM 51-31-01, REV 48. REPAIR CLASSDR FDEA201203090843Bushing · migratedLEFT WING (WING SIDE) OTBD FLAP INBD HINGE PIVOT HOLE REPAIR BUSHING FOUND MIGRATED. REPAIRED IAW EA 1-5750-160002 STEP 3, 7, 8 AND 9 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203090842Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP INBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REPAIRED IAW EA 1-5750-160002, STEP 4 AND 5 PART 1. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100, REV 114.SDR FDEA201203090841Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP INBD HINGE LOWER MOUNT INBD HOLE FOUND CORRODED. REPAIRED IAW EA 1-5750-160002, PART 1, STEP 2,7,8,9 AND 10. REPAIR CLASSIFIED AS MAJOR IAW GMM 6-2-100.SDR FDEA201203090840Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP INBD HINGE LOWER MOUNT OTBD HOLE FOUND CORRODED. REPAIRED IAW EA 1-5750-160002, PART 1, STEP 2.SDR FDEA201203090839Bushing · wornLEFT WING (WING SIDE) OTBD FLAP INBD HINGE, INBD ACTUATOR, HOLE BUSHING WORN. REPAIRED IAW EA 1-5750-160002, PART 1, STEP 1, 7, 8 AND 9 .SDR FDEA201203090838Bushing · wornLEFT WING (WING SIDE) OTBD FLAP INBD HINGE OTBD ACTUATOR HOLE BUSHING WORN. REPAIRED IAW EA1-5750-160002, PART 1 STEP 1, 7, 8 AND 9 .SDR FDEA201203090837Bushing · wornLEFT WING (WING SIDE) OTBD FLAP OTBD HINGE INBD ACTUATOR HOLE BUSHING WORN. MEASURED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72. EXISTING HOLE DIA 1.254", MAX HOLE DIA 1.220", BUSHING FABRICATED AND INSTALLED IAW STEP 9 AND 10. WASHER FABRICATED IAW SSDR FDEA201203090836Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP OTBD HINGE SIDE LOAD FITTING UPPER HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72 . EXISTING HOLE DIA. 0.398", FINAL HOLE 0.4095", MAX HOLE DIA. 0.391", BUSHING FABRICATED AND INSTALLED PER STEPSDR FDEA201203090835Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP OTBD HINGE SIDE LOAD FITTING LOWER HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72 EXISTING HOLE DIA. 0.398", FINAL HOLE DIA. 0.4095", MAX HOLE DIA. 0.391", BUSHING FABRICATED AND INSTALLED IAW SDR FDEA201203090834Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP OTBD HINGE SIDE LOAD FITTING SURFACE FOUND CORRODED. REWORKED IAW REV 72 UPPER FACE EXISTING THICKNESS: 0.413", MATERIAL REMOVED :0.003", REMAINING THICKNESS :0.410", LOWER FACE EXISTING THICKNESS: 0.410", MATERIAL REMOVED :0SDR FDEA201203090833Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP OTBD HINGE LOWER MOUNT INBD HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72. MAX ALLOWABLE DIA.0.584", EXISTING HOLE DIA 0.538", FINAL HOLE DIA 0.595", BUSHING FABRICATED AND INSTALLED IAW STEP SDR FDEA201203090832Hinge Fitting · corrodedLEFT WING (WING SIDE) OTBD FLAP, OTBD HINGE LOWER MOUNT OTBD HOLE FOUND CORRODED. REWORKED AND FOUND OUT OF LIMITS IAW CMM 57-44-09, REV 72. EXISTING HOLE DIA 0.585", FINAL HOLE DIA.0.597", MAX HOLE DIA 0.584". BUSHING FABRICATED AND INSTALLED AS IAW STESDR IPXA2M72473Spar · damagedINSPECTION TYPE:2C, 2 SHEARED FASTENERS ON THE NR 4 BANJO FITTING TO PYLON CARRY-THROUGH CAP RT SIDE. REPAIRED THE VERTICAL STAB "BANJO FITTING" RT SIDE CARRY-THROUGH CAP IAW EO 5530-46430-A AND STA SA EA 011-5530-01-A3736 REV IR.SDR FDEA201203070796Attach Fitting · crackedRIGHT WING T/E OTBD FLAP L/E STOP BOLT ATTACHMENT FITTING FOUND CRACKED. ATTACH FITTING REMOVED AND REPLACED AS PER EA 1-5750-160011.SDR FDEA201203070795Attach Fitting · crackedLEFT WING T/E OTBD FLAP L/E STOP BOLT ATTACHMENT FITTING FOUND CRACKED. FITTING REMOVED AND REPLACED AS PER EA 1-5750-160010. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100 REV 114.SDR IPXA2M72551Bolt · shearedINSPECTION TYPE: 2C, DURING INSPECTION, FOUND ONE SHEARED BOLT AT VERTICAL STAB REAR SPAR NR 4 BANJO FITTING TO PYLON CARRY-THROUGH LEFT SIDE. REPAIRED BANJO FITTING IAW EA 011-5530-01-A3735, REV IR AND EO MD11-5530-46438-A.SDR IPXA2M72385Doubler · crackedINSPECTION TYPE: 2C, RT WING FIXED L/E COMPT THRU ACCESS 618GB BEADED DOUBLER CRACKED ABOVE OTBD OF FUEL RECEPTACLE. REPAIRED RT WING FIXED L/E INTERNAL BEADED DOUBLER BETWEEN XOS643-648 IAW SRM 57-40-02, REPAIR 9, FIG 203 AND EO MD11-5730-42916-C.SDR IPXA2M72354Skin · crackedINSPECTION TYPE:2C, LT WING L/E IS CRACKED AT NR 14 SLAT TRACK CUT-OUT STA XOS894. REPAIRED LT WING L/E EXTERNAL SKIN IAW SRM 57-40-02, REPAIR 7, FIG 201.SDR IPXA2M72314Doubler · crackedINSPECTION TYPE:3C, RIGHT WING FIXED L/E BAY BEADED DOUBLER BETWEEN XOS 759-763 CRACKED INBD OF NR 12 SLAT TRACK. REPAIRED RT WING FIXED L/E INTERNAL BEADED DOUBLER IAW SRM 57-40-02, REPAIR 9, FIG 203 AND EO MD11-5730-42916-C.SDR IPXA12M72091Ground Stud · looseEMERGENCY EXIT LIGHTS INOPERATIVE, STAYS ON. FOUND HIGH RESISTANCE AT PIN 7 OF P1-1756B. TIGHTENED GROUND STUD AT 905R. OPS CHECKED GOOD IAW 33-51-01-5.SDR FDEA201203060790Skin · crackedRIGHT WING FIXED L/E SKIN FOUND CRACKED AT NR 8 SLAT TRACK CUTOUT INBD SIDE, LOWER CORNER. REPAIR CARRIED OUT AS PER SRM 57-40-02 REPAIR 7 FIG.201 REV 48. REPAIR CLASSIFIED MAJOR AS PER GMM 6-2-100 REV 114.
Back to Boeing MD-11F