Boeing 737-8H4

Service difficulty reports · 24,314

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = '7378H4'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWAA2022032887738Strip · looseFLOOR ILLUMINATION STRIP AT SEAT 12C LOOSE / [01] RE-INSTALLED FLOOR STRIP AT SEAT 12C PER SIPMar 24, 2022 · N8674B · Boeing 7378H4 · Emergency LightingSDR SWAA2022032886812Floor Panel · crackedFLOOR PANEL BREAKER ASSY. FLOOR PANEL BREAKER ASSY. CRACKED AT STA. 540 RT. OF CENTER / [01] REMOVED AND REPLACED FLOOR PANEL BREAKER ASSY. AT STA 540 PER AMM 53-21-00. SRM 51-40-02; {REF FOR FASTENERS INSTALLATION. }Mar 24, 2022 · N8659D · Boeing 7378H4 · Fuselage Floor PanelSDR SWAA2022042686723Wedge · delaminatedLEFT HAND I/B MAIN FLAP TRAILING EDGE WEDGE HAS AREA OF DELAM. (MARKED). / [01] OK TO INSTALL WEDGE;[02] REMOVED DAMAGE PER SRM 57-53-01-2R-7;[03] VERIFIED REMOVED DAMAGE PER SRM 57-53-01-2R-7;[04] C/A #1 ENTERED IN ERROR;[05] REMOVED AND REPLACED R/H WING ; IMar 23, 2022 · N8625A · Boeing 7378H4 · Trailing Edge FlapsSDR SWAA2022042686727Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE L/H TRANSITION ANGLE HAS NUMEROUS CORROSION AREAS FROM STA 514 TO STA 500I. / [01] LOCATED AND DRILLED HOLES FOR NEW PART FROM LBL 24 STA 500 TO STA 500I PER SRM 51-40-05;[02] L/H TRANSITION ANGLE REPLACED FROM STA 500-500IMar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686726Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE 'L' ANGLE IS CORRODED AT STATION 500I FROM RBL 24 TO LBL 24. / [01] REMOVED AND REPLACED L ANGLE AT STA 500I FROM RBL 24 TO LBL 24 REF SRM 51-40-02.;[02] INSPECTED WORK PERFORMEDMar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686728Angle · corrodedIN THE FORWARD CARGO COMPARTMENT THE R/H TRANSITION ANGLE HAS NUMEROUS AREAS OF CORROSION FROM STA 500A TO STA 500I. / [01] REMOVED AND REPLACED R/H TRANSITION ANGLE PER SRM 51-40-02;[02] 4 EA. FASTENERS MISSING IN ANGLE AT R/H AFT BULKHEAD THAT WERE REMOVED FMar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686729Web · crackedCORROSION ON AFT CARGO DOOR CUTOUT BEADED WEB / [01] FOUND CORROSION DAMAGE TO BE OUT OF LIMITS PER SRM 53-60-15-1A-1.015 DEPTH; .030 REMAING;.045 WEB.;[02] STEP 1 C/W;[03] REMOVED BEADED WEB FOR REPLACEMENT PER SRM 51-40-02.;[04] MATCH DRILLED AND COUNTERSANKMar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686732Angle · corrodedCORROSION ON L/H TRANSITION ANGLE STA 747-767 / [01] CORROSION IS OUT OF LIMITS .REMOVED L/H TRANSITION ANGLE FROM STA 727G+10 TO STA 807 +10 FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED NEW SECTION FROM STA. 727G + 10 TO STA. 807 + 10 ; AND DRILL HOLES PER Mar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686736Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 727H-727I / [01] COMPLIED WITH MEASUREMENTS REQUIREMENT.;[02] REMOVED AND REPLACED RH TRANSITION ANGLE STA 727E +10 TO STA 767 PER SRM 53-00-53-2R-5. REFERENCE NONROUTINE TTG8Q00BFQSU FOR WORK ACCOMPLISHED.;[03] INSPECTED Mar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686737Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 727G-727H / [01] CORROSION FOUND TO BE OUT OF LIMITS. REMOVED R/H TRANSITION ANGLE FROM STA 727E+10 TO STA 767 FOR REPLACEMENT PER SRM 51-40-02.;[02] LOCATED HOLES ON NEW TRANSITION ANGLE STA 727E+10 TO 767 PER SRM 51-40-0Mar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042686740Angle · corrodedCORROSION ON R/H TRANSITION ANGLE STA 767-787 / [01] MEASUREMENT REQUIREMENT .;[02] REMOVED AND REPLACED PER SRM 51-40-02 .Mar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042090989Transition Panel · missingSEVERAL NUT PLATES MISSING AFT CARGO R/H TRANSITION ANGLE STA 727F-727H / [01] REMOVED AND REPLACED RH TRANSITION ANGLE AND BONDED NUTPLATES STA 727E +10 TO STA 767 PER SRM 51-40-10-2R-0 AND SRM 53-00-53-2R-5. REFERENCE NONROUTINE TTG8Q00BFQSU FOR WORK ACCOMPLMar 23, 2022 · N8625A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042086724Flap · delaminatedRIGHT HAND INBOARD MAIN FLAP T/E WEDGE HAS AREA OF DELAM. (MARKED) / [01] REMOVED AND REPLACED R/H WING ; I/B TRAILING EDGE FLAP WEDGE IAW SRM 51-40-02 AND 51-40-04.;[02] INSPECTED WORK PERFORMED IN CORRECTIVE ACTION #1. WADE MOREY (TECHNICIAN); 02-APR-2022 17Mar 23, 2022 · N8625A · Boeing 7378H4 · Trailing Edge FlapsSDR SWAA2022041887206Attach Bracket · damagedFORWARD CARGO BAY CLIP AT BS 400 FRAME AFT SIDE WL 154 LBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 400 AFT SIDE OF FRAME WL 154 LBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505;[02] OK TO INSTALL.;[03] VERIFIED DRILMar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887207Bracket · damagedFORWARD CARGO BAY CLIP AT BS 440 FRAME AFT SIDE WL 154 LBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 440 AFT SIDE OF FRAME WL 154 LBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505. OK TO INSTALL.;[02] VERIFIED DRILL UPMar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887208Bracket · damagedFORWARD CARGO BAY CLIP AT BS 500H FRAME AFT SIDE WL 154 LBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 500H AFT SIDE OF FRAME WL 154 LBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505. OK TO INSTALL.;[02] VERIFIED DRILL Mar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887209Baffle · damagedFORWARD CARGO BAY BAFFLE AT BS 500 TO 500A WL 154 LBL 25 IS DAMAGED / [01] REMOVED DAMAGED BAY BAFFLE; LOCATED AND DRILLED NEW BAY BAFFLE BTW BS 500 AND 500A WL 154 LBL 25 IAW SRM 51-40-02-0G-0;51-40-05-0G-0 AND DWG 143A7505. OK TO INSTALL;[02] VERIFIED DRILL Mar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887210Baffle · damagedFORWARD CARGO BAY BAFFLE BETWEEN BS 500G AND 500H WL 154 RBL 25 IS DAMAGED / [01] REMOVED DAMAGED BAY BAFFLE; LOCATED AND DRILLED NEW BAY BAFFLE BTW BS 500G AND 500H WL 154 RBL 25 IAW SRM 51-40-02-0G-0;51-40-05-0G-0 AND DWG 143A7505. OK TO INSTALL.;[02] VERIFIMar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041886649Floor Panel · peelingFLOOR PANEL 221BF HAS PEELING FIBERGLASS PLIES ON UPPER SURFACE / [01] IDENTIFIED PANEL 221BF MATERIAL IAW SRM 53-00-50-0I-1 FIGURE 2 TABLE 2 <BR>DAMAGED AREA EXCEEDS ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-50-1A-1 PAR.4 B <BR>DAMAGE IS REPAIRABLE IAW SRM 53-00-Mar 23, 2022 · N8624J · Boeing 7378H4 · Fuselage Floor PanelSDR SWAA2022041287468Transition Panel · corrodedFORWARD CARGO COMPARTMENT CORROSION FOUND ON RH TRANSITION ANGLE UPPER SURFACE FORM STA 500A-500B; RBL 24; AND WL 156 / [01] FOUND DAMAGE TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2;[02] REMOVED R/H TRANSITION ANGLE FROM STA 500A TO STA 500I; PICKED UP HOLES; DEMar 23, 2022 · N8686A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041287466Support Angle · corrodedFORWARD CARGO COMPARTMENT CORROSION FOUND ON AFT BULKHEAD FLOOR SUPPORT ANGLE UPPER SURFACE AT STA 500I; LBL 24 TO RBL 24; AND WL 156. / [01] FOUND TO BE OUT OF LIMITS IAW SRM 53-30-08-1A-1 REMOVED ANGLE PER SRM 51-40-02; DRILLED NEW PART; AND OK TO INSTALL;[0Mar 23, 2022 · N8686A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041287176Angle · chafedVERTICAL STABILIZER PANEL MATING SURFACES ON THE RIGHT FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE HAVE AREAS OF CHAFFING FROM CONTACT OF CLOSURE PANELS / [01] REMOVED FWD AND AFT RH SIDE SKATE ANGLES IAW SRM 51-40-02.;[02] INSTALLED RH FWD SKATE ANGLE IAW SRMar 23, 2022 · N8686A · Boeing 7378H4 · Vertical StabilizerSDR SWAA2022041287175Angle · chafedVERTICAL STABILIZER PANEL MATING SURFACES ON THE LEFT FUSELAGE FIN TO BODY INTERFACE CLOSURE ANGLE HAVE AREAS OF CHAFFING FROM CONTACT OF CLOSURE PANELS. / [01] REMOVED LEFT AFT SKATE ANGLE PER SRM 51-40-02.;[02] REMOVED AND REPLACED L/H AFT SKATE ANGLE PER SRMar 23, 2022 · N8686A · Boeing 7378H4 · Vertical StabilizerSDR SWAA2022032887123Slide · out of positionL2 DOOR SLIDE RUBBING ON DOOR OPENING / [01] REPOSITIONED L2 DOOR SLIDE PER MT 725-61-06 AND AMM 25-66-07Mar 23, 2022 · N8322X · Boeing 7378H4 · Escape SlideSDR SWAA2022042086602Support Plate · corrodedAFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS727G+13 TO BS807 LBL21 WL 156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 747+10 LBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'X1'Mar 22, 2022 · N8628A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042086604Support Plate · corrodedAFT CARGO BAY R/H FLOOR TO SIDEWALL SUPPORT PLATE HAS AREAS OF CORROSION BS 727E+12 TO BS767 RBL 21 WL156 / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 727F+10 RBL 21 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.040 IN NUMEROUS 1'XMar 22, 2022 · N8628A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042086601Web · corrodedAFT CARGO BAY SUBTHRESHOLD WEB HAS CORROSION BS 8007+18 RBL25 WL 156 / [01] EVALUATED CORROSION ON SUBTHRESHOLD WEB BS 807+18 RBL 25 WL 156; FOUND 0.015 REMOVED FROM ORIG 0.045 IN 1'X1' AREAS FOUND TO BE OUT OF LIMITS PER SRM 53-60-15-1A-1 USING DIAL DEPTH GAUMar 22, 2022 · N8628A · Boeing 7378H4 · Fuselage Main, StructureSDR SWAA2022042086600Shield · corrodedAFT CARGO BAY ATTACH ANGLE UNDER SHIELD HAS CORROSION BS 767+3 RBL21 WL 156 / [01] EVALUATED CORROSION ON ATTACH ANGLE UNDER SHIELD BS 767+3 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02Mar 22, 2022 · N8628A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022042086603Shield · corrodedAFT CARGO BAY SHIELD HAS CORROSION BS 767+3 RBL21 WL 156 / [01] EVALUATED CORROSION ON SHIELD BS 767+3 RBL 21 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1.;[03] RMar 22, 2022 · N8628A · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041887197Baffle · damagedFORWARD CARGO BAY BAFFLE BETWEEN BS 500B AND 500C LBL 20 WL 154 IS DAMAGED / [01] CORRECTION TO TASK DETAIL SHOULD STATE ' FORWARD CARGO BAY BAFFLE BETWEEN BS 500B AND 500C LBL 25 WL 154 IS DAMAGED ';[02] REMOVED DAMAGED BAY BAFFLE; LOCATED AND DRILLED NEW BAYMar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887201Attach Bracket · damagedFORWARD CARGO BAY ATTACH CLIP BS 500G FWD SIDE OF FRAME WL 154 RBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 500G FWD SIDE OF FRAME WL 154 RBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505.;[02] OK TO INSTALL;[03] VERIMar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887202Attach Bracket · damagedFORWARD CARGO BAY ATTACH CLIP BS 500G AFT SIDE OF FRAME WL 154 RBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 500G AFT SIDE OF FRAME WL 154 RBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505.;[02] OK TO INSTALL;[03] VERIMar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887203Attach Bracket · damagedFORWARD CARGO BAY ATTACH CLIP BS 500H FWD SIDE OF FRAME WL 154 RBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 500H FWD SIDE OF FRAME WL 154 RBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505.;[02] OK TO INSTALL;[03] VERIMar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041887204Attach Bracket · damagedFORWARD CARGO BAY ATTACH CLIP BS 500H AFT SIDE OF FRAME WL 154 RBL 25 IS DAMAGED / [01] REMOVED DAMAGED CLIP; LOCATED AND DRILLED NEW CLIP BS 500H AFT SIDE OF FRAME WL 154 RBL 25 IAW SRM 51-40-02-0G-0; 51-40-05-0G AND DWG 143A7505.;[02] OK TO INSTALL;[03] VERIMar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Main, Plate/SkinSDR SWAA2022041886647Structure · corrodedCORROSION ON BS947 UPPER CHORD LBL24 WL 208 / [01] UPDATED STEP 1 FOR APPLICABILITY OF REFERENCE;[02] SRM 53-70-51-1A;[03] STEP 1 COMPLETE;[04] UPDATED STEP 2;[05] STEP 2 COMPLETE;[06] UPDATED STEP 3 AND 4 FOR INTERCOSTAL REMOVAL.;[07] UPDATE OF STEPS 5-17.;[0Mar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886648Structure · corrodedCORROSION ON BS947 UPPER CHORD RBL24 WL 208 / [01] UPDATED STEP 1 FOR APPLICABILITY;[02] STEP 1 COMPLETE;[03] UPDATED STEP 2. PER SRM 53-70-51;[04] CORROSION WAS FOUND TO BE OUT OF LIMITS AT BS 947 UPPER CHORD RBL 24 WL 208 AT 1'X1' AREA. ORIGINAL MATERIAL 0.1Mar 22, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022033186549Battery Pack · inoperativeR/H EMERGENCY LIGHTS. 2 R/H EMERGENCY LIGHTS OUT ON R/H VALANCE / [01] REPLACED EMERGENCY LIGHT BATTERY PACK AND CHARGER OPS CHECKS GOOD PER MM 33-51-06;[02] VERIFIED REPLACEMENT OF BATTERY PACK PER AMM 33-51-06.Mar 22, 2022 · N8601C · Boeing 7378H4 · Emergency LightingSDR SWAA2022032886543Light · inoperativeAFT SERVICE DOOR EMERG. EXIT LIGHT INOP / [01] RELAMPED PER AMM 33-51-04. NO HELP.;[02] REMOVED AND REPLACED M01672 BATTERY PACK PER AMM 33-51-06Mar 22, 2022 · N8639B · Boeing 7378H4 · Emergency LightingSDR SWAA2022041886288Gusset · crackedCRACK ON FWD CARGO BAY GUSSET AT BS 500I R/H STRINGER 19.(MARKED) / [01] REMOVED FWD CARGO BAY GUSSET AT BS 500I STR 19 R/H PER SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED NEW GUSSET PER SRM 51-40-05-0G-0 AND DWG 143A7902. OK TO INSTALL GUSSET;[03] VERIFIED CORMar 21, 2022 · N8624J · Boeing 7378H4 · Cargo CompartmentsSDR SWAA2022041888804Scuff Plate · crackedAFT CARGO BAY FWD CORNER SCUFF PLATE IS CRACKED ' MARKED ' / [01] WELDED CRACK ON ACB; FWD CORNER SCUFF PLATE USING ER 4043 ALUMINUM FILLER ROD LOT # 1131216 PER SRM 53-60-15-2R-1 PARA 4.B. (2) AND (4)<BR>WELDING MACHINE CALIBRATION ID E10583; S/N; KJ256554;[0Mar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886284Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 400+18; BS 420+9; BS 420+10; BS 420+13; BS 440+2; BS 500+10; BS 500+15; BS 500+19; BS 500A+2; BS 500A+7. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 440+2 REMMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886290Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500A+11; BS 500A+15; BS 500A+19; BS 500B+2; BS 500B+19; BS 500C+2; BS 500C+11; BS 500D+7; BS 500E+7. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500B+19 REMOVMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886285Support · corrodedCORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24 BS 500G+2; BS 500G+11; BS 500G+15; BS 500G+19; BS 500H+7; BS 500H+11; BS 500H+16. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 500G+19. REMOVED 0.020' IN A AREA OMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886286Support · corrodedCORROSION ON FWD CARGO BAY FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 400+6; BS 400+10; BS 400+14. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 400+10 REMOVED 0.020' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.040' FOUNMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886294Shield · corrodedCORROSION ON FWD CARGO BAY FWD CARGO BAY FWD SHIELD AT RBL 24 BS 420+15. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION STEP 1;[03] REMOVED SHIELD PER SRM 51-40-02-0G-0;[04] LOCATMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886295Web · corrodedCORROSION ON FWD CARGO BAY FWD CARGO BAY DOOR THRESHOLD AT RBL 28 BS 440+9; BS 440+14; BS 480+4. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 461 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.045' FOUND TO BE OUT OF Mar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886296Shield · corrodedCORROSION ON FWD CARGO BAY FWD CARGO BAY AFT SHIELD AT RBL 24 BS 480+16. / [01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM.;[02] VERIFIED CORRECTIVE ACTION STEP 1.;[03] REMOVED SHIELD PER SRM 51-40-02-0G-0;[04] LOCAMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886287Support · corrodedCORROSION ON FWD CARGO BAY FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 500A+7; BS 500A+11; BS 500A+15; BS 500D+11; BS 500D+19; BS 500F+11; BS 500G+11; BS 500G+15; BS 500H+2; BS 500H+16. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATIMar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886298Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 20 BS 747+18; BS 767+7; BS 767+10; BS 767+14; BS 767+18. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 767+7 REMOVED 0.015' IN A AREA OF 1'X1' ORIGINAL THICKNESS 0.04Mar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous StructureSDR SWAA2022041886306Support · corrodedCORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 20 BS 727G+19; BS 727H+9; BS 727H+16; BS 727H+19; BS 727I+3; BS 727I+6; BS 727I+10; BS 727I+14; BS 727I+18; BS 727J+2. / [01] EVALUATED CORROSION AT ALL LOCATIONS; FOUND DEEPEST LOCATION TO BE AT BS 7Mar 21, 2022 · N8624J · Boeing 7378H4 · Fuselage Miscellaneous Structure
Back to Boeing 737-8H4