Boeing MD-11F

Service difficulty reports · 31,322

Newest first. General aviation reporting is voluntary.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE aircraft_model_key = 'MD11F'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UPS06M48531Seat Track · corrodedINSPECTION TYPE:4C SEAT TRACK AT FS 475 RBL 8.5 HAS SURFACE CORROSION. REMOVED SEAT TRACK AT FS 475 RBL 8.5, FABRICATED REPLACEMENT SEAT TRACK PER DWG WSP0826, AND INSTALLED IAW MD-11 SRM 51-31-01,51-33-01, AND 51-35-02.Oct 20, 2006 · N252UP · Doug MD11F · Fuselage, Seat/Cargo Attach FittingsSDR 06FDEA03730Seat Track · corrodedCARGO SEAT TRACK (STA 475, LT X=27.5) FOUND CORRODED. REPAIR CARRIED OUT AT M/D CARGO SEAT TRACK AT STA475 LT X=27.5 AS PER SRM 53-70-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MINOR AS PER GMM 6-2-100.Oct 20, 2006 · N604FE · Doug MD11F · Fuselage, Seat/Cargo Attach FittingsSDR UPS06M48266Shield · chafedINTERMITTENT FIRE WARNING ON NR 1 ENGINE. THRUST LEVER WAS RETARDED TO IDLE, ALL "FIRE DET FAULT" AND FIRE ALERTS WENT AWAY. OPERATED REMAINDER OF FLIGHT WITH NR 1 AT IDLE. CHECKED A/B FIRE LOOP. ALL ELEMENTS, OK. CHECKED ALL BLEED DUCTS, SECURITY CHECK OOct 17, 2006 · N283UP · Doug MD11F · Fire DetectionSDR UPS06M48529Floor Panel · corrodedINSPECTION TYPE:4C COURIER FLOOR PANELS HAS SEVERAL AREAS OF EXFOLIATED CORROSION BEHIND COURIER SEAT AND POSSIBLE CORROSION BEHIND GALLEY. REMOVED AND REPLACED 13 EACH COURIER FLOOR PANELS AT F/S 490 IAW MD-11 AMM 53-21-00 AND 25-59-13 IAW SMITHS AEROSPACE DOct 14, 2006 · N252UP · Doug MD11F · Fuselage Floor PanelSDR UPS06M48250Indicator · malfunctionedINSPECTION TYPE: N/A EVACUATION SLIDE REMOTE PRESSURE PRESS-TO-TEST IND. SYS DOOR 1L LIGHT DOES NOT GO OFF. LIGHT ON DIM IN FLIGHT. PRESS-TO-TEST NORMAL ON GROUND. ON T/S FOUND LIGHT HOLDER INCORRECTLY SEATED. RESEATED LAMP HOLDER AND PERFORMED ADJ/TEST IAW Oct 14, 2006 · N275UP · Doug MD11F · Escape SlideSDR UPS06M48240Warning Message · illuminatedATB - LEVEL 2 "AILERON DEFLECT DISAGREE" UPON CLEAN UP AFTER T/O. FOLLOWED CHECKLIST PROCEDURES AND WHEN COMPLETED, THE LEVEL 2 ALERT RETURNED. FUEL WAS DUMPED AND A/C RETURNED TO ANC. DEFERRED PER MEL 27-13-2-01-1, PLACARD INSTALLED, M335539. DMP 27-13-2 Oct 12, 2006 · N281UP · Doug MD11F · Aileron Control SystemSDR UPS06M48228Battery · inoperativeFOUND EMERGENCY EXIT LIGHT INOP. TRANSFERRED TO DMI M335480 PER MEL 33-50-4. REPLACED EMERGENCY LIGHTS BATTERY IAW MM 33-51-01-4. TESTS GOOD M335480 CLEARED PLACARD REMOVED.Oct 11, 2006 · N283UP · Doug MD11F · Emergency LightingSDR UPS06M48187A/C Pack · odorWITH THE NR 1 PACK ON, A NOXIOUS ODOR WAS ENTERING THE FLIGHT DECK THROUGH THE AIR CONDITIONING SYSTEM. SELECTING THE NR 1 PACK OFF ELIMINATED THE PROBLEM. OPERATED NR 1 PACK FULL HEAT, FULL COLD WITH NO ILL ODORS. ALL PACK TEMPS NML, OK FOR SERVICE.Oct 3, 2006 · N272UP · Doug MD11F · Cabin Cooling SystemSDR UPS06M48316Skin · damagedINSPECTION TYPE:C CTR CGO AFT CUT-OUT CENTER AREA FOUND WITH BLEND OUT. CUSTOMER REQUEST TO INSTALL DOUBLER PER SRM. SKIN BLEND OUT MAT`L TRIM OFF PER SRM 53-50-00 FIG 16 V.I R.38. HFEC C/O IAW DAC NDT SPM R.12 PART 06-10-01.001 ON TRIMMED EDGE AND FOUND NOOct 2, 2006 · N285UP · Doug MD11F · Fuselage Main, Plate/SkinSDR UPS06M48261Strut · corrodedINSPECTION TYPE:C FWD CARGO, DURING CARRY-OUT OF WORK AT AFT BULKHEAD, AFTER REMOVAL OF ANCHOR NUT, FOUND CORROSION AT STRUT AT STA 6-72, X=18.25 LT AT FLOOR LEVEL AS MARKED FWD CARGO STA 6-72,X=18.25 LT FLOOR LEVEL CORROSION STRUT ATTACH PARTS REMOVED PER SRMOct 1, 2006 · N285UP · Doug MD11F · Fuselage Miscellaneous StructureSDR UPS06M48168Bulb · inoperativeLEFT ENTRY DOOR FORWARD EMERGENCY EXIT LIGHT HAS ONE LIGHT OUT. REMOVED AND REPLACED BULB LIGHT. OPS CHECK NORMAL.Oct 1, 2006 · N271UP · Doug MD11F · Emergency LightingSDR UPS06M48174Battery · inoperativeEMERGENCY BATTERY LT 1 LOW FAULT. REMOVED AND REPLACED EMERGENCY LTS BATTERY PER AMM 33-51-04-4. OPS TEST PER AMM 33-51 -01-5 GOOD.Sep 30, 2006 · N278UP · Doug MD11F · Emergency LightingSDR UPS07M49090Spar · corrodedINSPECTION TYPE:C LEFT WING - UPPER SKIN AT AFT SPAR, SKIN BULGING (CORROSION) IN 3 DIFFERENT AREAS. REAR SPAR XORS 683, 738, 735, 825 CORR REMOVED FOUND WITHIN LIMIT PER SRM 57-20-00 FIG 16 R38VI. XORS 799 CORR REMOVED EXCEED LIMIT PER SRM 57-20-00 FIG 6VIRSep 29, 2006 · N286UP · Doug MD11F · Wing SparSDR UPS06M48169Engine · inoperativeAT 1500 FT ON FINAL, NR 1 ENG ROLLED BACK TO EPR=.8, N1=14.1; EGT-512 N2 14.0 FF BELOW 1000 LBS. ENGINE 1 RPM LO =LEVEL 2 ALERT ILLUMINATED. NO RESPONSE ON THROTTLE MOVEMENT. CONTINUED APPROACH. ON LANDING, ROLLOUT WHEN NR 1 BROUGHT BACK. DRAINED FUEL FORSep 29, 2006 · N274UP · Doug MD11F · Engine (Turbine/Turboprop)SDR UPS07M49089Structure · dentedINSPECTION TYPE:C LEFT WING - NR 4 SLAT L/E DENTS (2), 3 INCHES OUTBOARD OF INBOARD EDGE. LEFT WING NR 4 SLAT L/E DENTS 2 EA MEASRUED 0.063 & 0.043 DEEP 0.5 INCH APART EXCEED LIMITS IAW SRM 57-10-00 FIG 6VI. DAMAGED AREA TRIMMED OUT PER SRM 57-10-00 FIG 5 VISep 28, 2006 · N286UP · Doug MD11F · Leading Edge DevicesSDR UPS06M48415Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 27 BARREL NUT BORE CORRODED. CORROSION REMOVED PER SRM 51-21-01 VOL II R38. BORE REAMED TO 1.178 DIA REMAINING BLEND OUT 0.070 DEEP, BOTTOM SURF CLEANED FOUND EXCEED EO LIMITS. B/N BORE BLEND OUT AND BOTTOM PERI RADISep 28, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48427Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 30 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM51-21-01 V.II R.38. BORE REAMED TO 1.178"DIA. REMAINING BLEND OUT FOUND EXCEEDED LIMITS PER EO MD11-551 -19409K. REPAIR SLEEVE BUSHING FAB AND PROTSep 27, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48235Shear Tie · corrodedINSPECTION TYPE:C CTR CARGO, STA 1721, LONGERON L49-R49 FRAME SHEAR TIE CORROSION AS MARKED CTR CARGO STA 1721 LONGERON L-49-R49 FRAME CORROSION SHEAR TIE ATTACH SUPPORT AND FASTENERS REMOVED PER SRM 51-31-01 V.II R.38.CORROSION SHEAR TIE REMOVED PER SRM 51-31Sep 27, 2006 · N285UP · Doug MD11F · Fuselage Internal Mounting StructureSDR 06FDEA03446Seat Track · damagedM/D CARGO SEAT TRACK BS 755, RT X=8.5 FOUND EDGE BROKEN. REPAIR CARRIED OUT AS PER SRM 53-70-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.Sep 27, 2006 · N589FE · Doug MD11F · Fuselage, Seat/Cargo Attach FittingsSDR 06FDEA03445Frame · damagedM/D CARGO LT BS 1701 FOUND DOUBLER SURFACE WITH SCRATCH. REPAIR CARRIED OUT AT M/D CARGO LT BS 1701 FRAME AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.Sep 27, 2006 · N589FE · Doug MD11F · Fuselage Main, Plate/SkinSDR 06FDEA03444Frame · dentedM/D CARGO LT STA 1721 FOUND FRAME DENT. REPAIR CARRIED OUT AT M/D CARGO LT BS 1721 FRAME AS PER SRM 53-30-00 FIGURE 1 VOLUME I. REPAIR CLASSIFIED AS MAJOR AS PER GMM 6-2-100.Sep 27, 2006 · N589FE · Doug MD11F · Fuselage Main, FrameSDR UPS06M48048Slide · will not armRT ENTRY DOOR SLIDE WILL NOT ARM, RT SIDE GIRT BAR INSTALLED AND SECURE PER AMM 25-61-15.Sep 26, 2006 · N274UP · Doug MD11F · Escape SlideSDR UPS06M48435Structure · corrodedINSPECTION TYPE:C LT HORIZ STAB FOUND NR 28 BARREL NUT BORE CORRODED CORROSION REMOVED AT B/N BORE AS PER SRM 51-21-01 V.II R.38. BORE REAMED TO 1.178" DIA REMAINING BLEND OUT 0.015" DEEP, BOTTOM SURFACE CLEANED, REMAINING BLEND OUT 0.045" DIA DEEP FOUND Sep 25, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48425Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 28 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM51-21-01 V.II R.38. BORE REAMED TO 1.178" DIA REMAINING BLEND OUT 0.050" DEEP BOTTOM THRU, EXCEEDED PER B/N EO 5510-19409K. REPAIR BUCKET BUSHING FASep 25, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48416Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 34 BARREL NUT BORE CORRODED. CORROSION AT B/N BORE REMOVED PER SRM 51-21-01VOL IIR 38. BORE REAMED TO 1.178D IA REMAINING BLEND OUT 0.040 BOTTOM SURFACE CLN AND REMAINING BLEND OUT 0.035 DEEP EXCEED EO LIMITS. B/N BOSep 25, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48049Girt Bar · looseL1 DOOR GIRT BAR LOOSE. INSTALLED AND SECURED L1 DR GIRT BAR PUSHROD IAW AMM 25-61-01-4.Sep 25, 2006 · N271UP · Doug MD11F · Escape SlideSDR UPS06M48184Spar Cap · crackedINSPECTION TYPE:4C LE HORIZONTAL STAB "TEE CAP CRACKED 7 1/2" AT APPROX STA 182.00 TO 189.65. REMOVED DAMAGE, FABRICATED, AND INSTALLED REPAIR IAW SAA EA NR 011- 5510-01-A0447, UPS RAA ENGINEERING FILE NR: MD11-55-20135.Sep 24, 2006 · N251UP · Doug MD11F · Horizontal Stabilizer, Spar/RibSDR UPS06M48036Battery · dischargedINSPECTION TYPE: N/A EMERGENCY LT BAT 1 LOW MSG APPEARED DURING PREFLIGHT OPS.TRANSFERRED TO DMI M334273 IAW MEL 33-50-4. PLACARD INSTALLED. CARRY OUT TEST ON EMERGENCY LIGHT. PASS TEST WITH MESSAGE. NO FAULTS OBSERVED. THIS CLOSES DMI. PLACARD REMOVED.Sep 23, 2006 · N283UP · Doug MD11F · Emergency LightingSDR WRLA2006096Floorbeam · corrodedDURING 2C+12A+150M CHECK FOUND UPPER DECK CARGO FLOORBEAM CHANNEL CORROSION AT STA 496.5 X=22.5. REPLACED FLOORBEAM CHANNEL IAW SRM 51-33-01 VOL II REV 38, CONDITION CHECK ALL NORMAL.Sep 22, 2006 · N275 · Doug MD11F · Fuselage Main, Floor BeamSDR WRLA2006095Structure · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4, FOUND CORROSION ON HST LH BARREL NUT HOLE NR 4. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION IAW EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATED REPAIR BUSSep 22, 2006 · N275 · Doug MD11F · Horizontal Stabilizer StructureSDR WRLA2006094Structure · corrodedITEM: DURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 7. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION IAW EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATED REPASep 22, 2006 · N275 · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48430Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 22 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM 51-21-01 V.II R.38. BORE REAMED TO 1.067" DIA, REMAINING BLEND OUT 0.055"DEEP FOUND EXCEEDED LIMITS PER EO MD11-5510-19409K. B/N BORE REWORKED TO 1Sep 21, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48023Light · brokenEMERGENCY "ON" LIGHT ON OVERHEAD HAS A LIGHT BULB BROKEN IN SOCKET. PULLED OUT BROKEN LIGHT AND INSTALLED NEW BULB.Sep 21, 2006 · N278UP · Doug MD11F · Emergency LightingSDR UPS06M48437Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 18 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM 51-21-01 VII R.38. BORE REAMED TO 1.067" DIA BOTTOM BORED THRU, REMAINING SIDEWALL BLEND OUT IS 0.040" DEEP , EXCEEDED LIMITS PER B/N EO. REPAIR BUSep 19, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48436Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB FOUND NR 15 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM 51-21-01 V.II R.38. BORE REAMED TO 1.067" DIA REMAINING BLEND OUT 0.050" BOTTOM SURFACE CLEANED REMAINING BLEND OUT 0.030" DEEP EXCEEDED LIMITS PER Sep 19, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48428Structure · corrodedINSPECTION TYPE:C LT HORIZ STAB FOUND NR 35 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM 51-21-01 V.II R.38. BORE REAMED TO TO 1.178" DIA, REMAING BLEND OUT 0.050" EXCEEDED LIMITS PER EO MD11-5510 -19409K. REPAIR BUCKET BUSHING FAB ANDSep 19, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48234Cover Plate · corrodedINSPECTION TYPE:C AFT CGO, STA 1959, LONGERON R39-R40, FOUND COVER PLATE INTERFACE MOUNT AREA WITH SURFACE CORROSION AS MARKED. LONGERON FASTENERS REMOVED PER SRM51-31-01 V.II R.38 AT STA 1953 TO 19 64 L-39 AND L-40. CORROSION EXIT DOUBLER REMOVED PER SRM 51Sep 18, 2006 · N285UP · Doug MD11F · Fuselage Main, Plate/SkinSDR UPS06M48432Structure · corrodedINSPECTION TYPE:C RT HORIZ STAB, FOUND NR 35 BARREL NUT BORE CORRODED CORROSION AT B/N BORE REMOVED PER SRM 51-21-01 V.II R.38. BORE REAMED TO 1.178" DIA, REMAINING BLEND OUT 0.050" BOTTOM, 0.040" DEEP FOUND EXCEEDED LIMITS PER EO MD11-5510-19409K. REPAISep 17, 2006 · N285UP · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48407Fitting · gougedINSPECTION TYPE:C LT TRUNNION SUPPORT FITTING FWD HOLE FOUND SEVERAL GOUGE MARKS. REFER TO NRC 956648. HOLE REAMED TO 1.385 DIA PER SRM 53-40-00 VOL II R38 2. LOCAL BLEND AREA PER EN1336-06. FPI INSP C/O PER DACNDTSPM PART 08 R12 FOUND NO CRACK AND CORRODESep 17, 2006 · N285UP · Doug MD11F · Fuselage, Landing Gear Attach FittingsSDR UPS06M48194Support Fitting · crackedBLADDER CELL COMPT AT STA 1278.00 S-38R FOUND WEB SUPPORT FITTING CRACKED. REMOVED ATTACHED SUPPORT AND FASTENER ON FITTING PER SRM 51-31-01 V.II R .35.ANGLE P/N:AYB7035-12 M/F EXTRUDED 'T' P/N:S1362783 IAW DOUGLAS DWG AYB7035.FPI C/O PER DPS4.707 R.AW ON FABSep 14, 2006 · N285UP · Doug MD11F · Fuselage Main, Attach FittingsSDR UPS06M47983Switch · malfunctionedWITH EMERG LT SW IN ARM POS, EMERG LTS CAME ON IN SUPERNUMERARY AREA. EMERG LIGHTING SYS PLACARDED PER MEL 33-50-4. UPDATED DI LOG AND ISSUED M333406. PLACARD INSTALLED. T/S C/O R/R SWITCH S1-346 NO HELP. CHECKED WIRING IAW WDM 33-51-01 FOUND WIRE BROKEN OSep 12, 2006 · N282UP · Doug MD11F · Emergency LightingSDR UPS06M47978Warning Message · illuminatedNR 3 ENG ANTI-ICE DISAGREE AND TAIL ANTI-ICE DISAGREE. NR 3 ENG COWL ANTI ICE PRESS SWITCH TEST GOOD, REF M/M 30-22-02-5. CHECKED BAD DISAGREE LIGHT - STAYS ON. FOUND NR 3 ENG COWL ANTI-ICE VALVE LOCK IN CLOSED POSITION. RESET TO NORMAL. RAN ENG 3 SYSTEM. OPSep 12, 2006 · N284UP · Doug MD11F · Air Intake Anti/De-Ice SystemSDR WRLA2006085Barrel Nut · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 9. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATEDSep 12, 2006 · N275WA · Doug MD11F · Horizontal Stabilizer StructureSDR WRLA2006083Barrel Nut · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 6. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATEDSep 12, 2006 · N275WA · Doug MD11F · Horizontal Stabilizer StructureSDR WRLA2006082Barrel Nut · corrodedITEM: DURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 3. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRSep 12, 2006 · N275 · Doug MD11F · Horizontal Stabilizer StructureSDR UPS06M48238Intercostal · crackedINSPECTION TYPE:C EMP-AFT ACC COMPT AFT BULKHEAD TOP OF LATCH HOUSING ASSY FOUND INTERCOSTAL CLIP CRACKED. CRACKED INTERCOSTAL CLIP REMOVED PER SRM 51-33-01 V.II R.38. NEW INTERCOSTAL CLIP P/N:AJC7345-2 MACHINED USING 7075T6511 STOCK IAW DOUGLAS DWG AJC7345.Sep 11, 2006 · N285UP · Doug MD11F · Fuselage Miscellaneous StructureSDR 06FDEA03240Rib · crackedLEFT WING, AFTER REMOVAL OF NR 1 SLAT PERFORMANCE FAIRING FOUND FAIRING RIB CRACKED. REMOVED AND REPLACED AS PER SRM 51-35-01 VOLUME II. REPAIR CLASSIFIED AS MAJOR PER GMM 6-2-100.Sep 11, 2006 · N608FE · Doug MD11F · Wing, Rib/BulkheadSDR WRLA2006084Barrel Nut · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST LT BARREL NUT HOLE NR 8. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATEDSep 11, 2006 · N275WA · Doug MD11F · Horizontal Stabilizer StructureSDR WRLA2006093Barrel Nut · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST RT BARREL NUT HOLE NR 12. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATESep 11, 2006 · N275 · Doug MD11F · Horizontal Stabilizer StructureSDR WRLA2006092Barrel Nut · corrodedDURING 2C+12A+150M CHECK WHILE COMPLYING WITH EO 02-5510-098 REV 4 INSPECTION, FOUND CORROSION ON HST RT BARREL NUT HOLE NR 4. ACCOMPLISHED BARREL NUT REMOVAL AND INSPECTION PER EO 02-5510-098 SEC06, REMOVED CORROSION AND OVERSIZED BARREL NUT HOLE, FABRICATEDSep 11, 2006 · N275WA · Doug MD11F · Horizontal Stabilizer Structure
Back to Boeing MD-11F